RESUMO
INTRODUCTION: Severe obesity presents significant challenges in imaging and delivery of therapy, including pacemaker implant. METHODS AND RESULT: We present our experience implanting a leadless pacemaker (LP) in a severely obese man presenting with heart block. We describe our multidisciplinary approach using right internal jugular venous access and transesophageal imaging in lieu of fluoroscopy which failed to provide workable images in this instance. CONCLUSION: Ultrasound guided LP placement may have wider application in the midst of an ongoing obesity epidemic where fluoroscopy imaging is both limited and unsafe.
Assuntos
Marca-Passo Artificial , Humanos , Masculino , Obesidade Mórbida/complicações , Obesidade Mórbida/terapia , Resultado do Tratamento , Estimulação Cardíaca Artificial , Ecocardiografia Transesofagiana , Veias Jugulares/diagnóstico por imagem , Fluoroscopia , Desenho de Equipamento , Pessoa de Meia-Idade , Bloqueio Cardíaco/terapia , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/diagnósticoRESUMO
Background & objectives Neuronal hypoxia associated with conditions like traumatic brain injury and cardiac tachyarrhythmia has been implicated in causing hypopituitarism. Individuals with complete heart block (CHB) may be predisposed to develop anterior pituitary hormone dysfunction in the long term. The objective of this study was to investigate anterior pituitary hormone functions in individuals after CHB. Methods This prospective cohort study included 30 individuals (21 men and 9 women) with CHB requiring pacemaker implantation, who were evaluated at admission and then at a mean follow up of 12.4 ± 2.2 months to look for development of any degree of hypopituitarism. In addition to the measurement of hormones like follicle-stimulating hormone (FSH), luteinising hormone (LH), thyroid stimulating hormone (TSH), total tetra iodothyronines (TT4), free tetraiodothyronines (FT4), cortisol, insulin-like growth factor-1 (IGF-1), testosterone and estradiol, a fixed-dose glucagon stimulation test (GST) was performed to assess growth hormone (GH) and adrenocorticotrophic hormone (ACTH) axis. Results The mean age of the participants was 64.9 ± 11.3 yr. At follow up evaluation, 17 (56.7%) had low serum IGF-1, and among them, seven (23%) had growth hormone deficiency (GHD) (peak GH <1.0 ng/ml after GST). Six participants (20%) had ACTH deficiency (peak cortisol <9 ug/dl after GST) and one had TSH deficiency. None had prolactin (PRL) or gonadotropin deficiency. Overall, hormone deficiencies were observed in nine patients (30%). Interpretation & conclusions This pilot study detected loss of anterior pituitary hormones in a significant number of individuals of CHB at 12 months follow up. Unrecognised hypopituitarism may have resulted in significant morbidity and mortality in these individuals.
Assuntos
Bloqueio Cardíaco , Hipopituitarismo , Marca-Passo Artificial , Hormônios Adeno-Hipofisários , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Hipopituitarismo/sangue , Hipopituitarismo/fisiopatologia , Hipopituitarismo/tratamento farmacológico , Idoso , Bloqueio Cardíaco/sangue , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Hormônios Adeno-Hipofisários/sangue , Hormônios Adeno-Hipofisários/deficiência , Fator de Crescimento Insulin-Like I/metabolismo , Hormônio Adrenocorticotrópico/sangue , Hormônio Adrenocorticotrópico/deficiência , Tireotropina/sangue , Estudos Prospectivos , Hidrocortisona/sangue , Hormônio Foliculoestimulante/sangueRESUMO
When the atrioventricular node is damaged, accessory pathways can perform primary atrioventricular conduction but may spontaneously degrade during childhood. After surgical atrial septal defect repair during infancy, an adolescent male presented with fatigue due to iatrogenic complete atrioventricular node block with a degrading antegrade accessory pathway resulting in symptomatic bradyarrhythmia.
Assuntos
Eletrocardiografia , Fadiga , Humanos , Masculino , Adolescente , Fadiga/etiologia , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/etiologia , Feixe Acessório Atrioventricular/cirurgia , Feixe Acessório Atrioventricular/fisiopatologia , Comunicação Interatrial/complicações , Comunicação Interatrial/cirurgia , Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/cirurgia , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/etiologiaRESUMO
Cardiac reentry is a lethal arrhythmia associated with cardiac diseases. Although arrhythmias are reported to be due to localized propagation abnormalities, little is known about the mechanisms underlying the initiation and termination of reentry. This is primarily because of a lack of an appropriate experimental system in which activity pattern switches between reentry and normal beating can be investigated. In this study, we aimed to develop a culture system for measuring the spatial dynamics of reentry-like activity during its onset and termination. Rat cardiomyocytes were seeded in microelectrode arrays and purified with a glucose-free culture medium to generate a culture with a heterogeneous cell density. Reentry-like activity was recorded in purified cardiomyocytes, but not in the controls. Reentry-like activity occurred by a unidirectional conduction block after shortening of the inter-beat interval. Furthermore, reentry-like activity was terminated after propagation with a conduction delay of less than 300 ms, irrespective of whether the propagation pattern changed or not. These results indicate that a simple purification process is sufficient to induce reentry-like activity. In the future, a more detailed evaluation of spatial dynamics will contribute to the development of effective treatment methods.
Assuntos
Potenciais de Ação/fisiologia , Arritmias Cardíacas/fisiopatologia , Bloqueio Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/fisiologia , Microeletrodos/normas , Miócitos Cardíacos/fisiologia , Animais , Células Cultivadas , Modelos Animais , Ratos , Ratos WistarRESUMO
BACKGROUND: Exercise capacity is an important aspect of quality of life in patients undergoing pacemaker implantation. Device algorithms for ventricular pacing avoidance have been developed to avoid unnecessary and potentially harmful effects of right ventricular pacing. However, little data exists on the immediate response of these algorithms to sudden AV block during exercise. METHODS: The ventricular pacing avoidance algorithms of four pacemaker manufacturers were tested in an ex-vivo model. The RSIM-1500-USB Device-Interactive Heart Simulator (Rivertek Medical Systems, Inc.) was used to simulate three different scenarios: the first one starting with an initially conducted atrial pacing rate of 60 min-1 , the second one starting with an atrial rate of 120 min-1 and finally a scenario starting with an atrial rate of 150 min-1 . In all three scenarios, the initially conducted atrial rate was followed by a sudden, long lasting episode of third-degree AV-block. The response to those scenarios was recorded for each of the (brand-specific) ventricular pacing avoidance algorithms. RESULTS: In the first scenario, the simulation resulted in a ventricular pause of 1333 ms (Boston Scientific), 2000 ms (Medtronic and Microport), and 2340 ms (Biotronik). In the second and third scenario, different results were observed across devices. All simulations of the second and third scenario resulted in repetitive 2:1 block response (during eight cycles) in Boston Scientific and Biotronik devices. These scenarios were confirmed in patient cases. CONCLUSION: Simulator based observations of unanticipated pacemaker-induced 2:1 block response during exercise may explain clinical symptoms experienced by some patients having a two-chamber pacemaker.
Assuntos
Algoritmos , Nó Atrioventricular/fisiopatologia , Tolerância ao Exercício , Bloqueio Cardíaco/fisiopatologia , Marca-Passo Artificial , Eletrocardiografia , Humanos , Qualidade de VidaRESUMO
Cardiac amyloidosis (CA) is an increasingly recognized cause of heart failure, characterized by extracellular deposition of insoluble protein fibrils leading to progressive myocardial dysfunction. The most common types of cardiac amyloidosis are immunoglobin light-chain (AL) and transthyretin (ATTR). Conduction abnormalities are commonly encountered among patients with cardiac amyloidosis and are an important cause of morbidity and mortality. Abnormalities range from infra-Hisian intraventricular conduction delay and bundle branch block to complete atrioventricular block. Pacemaker placement in CA patients follows established guidelines, similar to those for patients without CA, with generally good efficacy. The role and appropriate timing of pacemakers for primary prevention of brady-arrhythmias in CA remains uncertain. While biventricular (BiV) pacing has been shown to improve clinical outcomes in patients with systolic heart failure without CA, there are few data examining the utility of BiV pacing in patients with CA. With the advent of effective treatments for AL and ATTR, appropriate application of pacing is important to support patients with CA and conduction disease through therapeutic trials. This systematic review summarizes the current literature examining the utility of pacing in CA.
Assuntos
Amiloidose/fisiopatologia , Amiloidose/terapia , Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Sistema de Condução Cardíaco/fisiopatologia , HumanosRESUMO
OBJECTIVES: We aimed to measure the frequency and factors associated with anodal stimulation in a pediatric population with epicardial pacing leads. BACKGROUND: In bipolar pacemakers, capture of the myocardium typically occurs at the cathode. However, AS with capture at the anode has been described. This has not been described in epicardial pacemakers. METHODS: Retrospective data were collected from patients ≤ 21 years of age with permanent bipolar epicardial ventricular pacemakers from 1/2017 to 1/2018. AS was defined as a clear change on surface ECG in at least one of the 12 leads assessed by two blinded pediatric electrophysiologists. RESULTS: Twenty-four bipolar leads in 23 patients were included in the study. One patient had both biventricular leads tested. Median age was 7.1 years (IQR 5.0-10.9), weight was 20.9 kg (IQR 16.5-33.5), and 65% were male. Testing was performed at a median of 2.8 years (IQR 1.6-6.1) after implant. Congenital heart disease was present in 57%. Complete heart block was the pacemaker indication in 78%. AS was identified in 16/24 (67%) of leads tested. Identification of AS was associated with presence of congenital heart disease (p = 0.004) and 3DD between electrodes (p = 0.04). CONCLUSIONS: AS is common in pediatric patients and was associated with a history of congenital heart disease and greater estimated 3DD between electrodes. The prevalent nature of AS may allow clinicians to utilize existing pacemakers as multisite pacing systems.
Assuntos
Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/terapia , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Criança , Pré-Escolar , Eletrocardiografia , Feminino , Humanos , Masculino , Estudos RetrospectivosRESUMO
Myocardial ischemia leads to conduction slowing, cell-to-cell uncoupling, and arrhythmias. We previously demonstrated that varying perfusate sodium (Na+) and calcium (Ca2+) attenuates conduction slowing and arrhythmias during simulated ischemia with continuous perfusion. Cardioprotection was selectively associated with widening of the perinexus, a gap junction adjacent nanodomain important to ephaptic coupling. It is unknown whether perfusate composition affects the perinexus or ischemic conduction during nonsimulated ischemia, when coronary flow is reduced or halted. We hypothesized that altering preischemic perfusate composition could facilitate perinexal expansion and attenuate conduction slowing during global ischemia. To test this hypothesis, ex vivo guinea pig hearts (n = 49) were Langendorff perfused with 145 or 153 mM Na+ and 1.25 or 2.0 mM Ca2+ and optically mapped during 30 min of no-flow ischemia. Altering Na+ and Ca2+ did not substantially affect baseline conduction. Increasing Na+ and decreasing Ca2+ both lowered pacing thresholds, whereas increasing Ca2+ narrowed perinexal width (Wp). A least squares mean estimate revealed that reduced perfusate Na+ and Ca2+ resulted in the most severe conduction slowing during ischemia. Increasing Na+ alone modestly attenuated conduction slowing, yet significantly delayed the median time to conduction block (10 to 16 min). Increasing both Na+ and Ca2+ selectively widened Wp during ischemia (22.7 vs. 15.7 nm) and attenuated conduction slowing to the greatest extent. Neither repolarization nor levels of total or phosphorylated connexin43 correlated with conduction slowing or block. Thus, perfusate-dependent widening of the perinexus preserved ischemic conduction and may be an adaptive response to ischemic stress.NEW & NOTEWORTHY Conduction slowing during acute ischemia creates an arrhythmogenic substrate. We have shown that extracellular ionic concentrations can alter conduction by modulating ephaptic coupling. Here, we demonstrate increased extracellular sodium and calcium significantly attenuate conduction slowing during no-flow ischemia. This effect was associated with selective widening of the perinexus, an intercalated disc nanodomain and putative cardiac ephapse. These findings suggest that acute changes in ephaptic coupling may serve as an adaptive response to ischemic stress.
Assuntos
Bradicardia/prevenção & controle , Cálcio/metabolismo , Bloqueio Cardíaco/prevenção & controle , Sistema de Condução Cardíaco/metabolismo , Frequência Cardíaca , Isquemia Miocárdica/metabolismo , Sódio/metabolismo , Potenciais de Ação , Animais , Bradicardia/etiologia , Bradicardia/metabolismo , Bradicardia/fisiopatologia , Circulação Coronária , Modelos Animais de Doenças , Cobaias , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/metabolismo , Bloqueio Cardíaco/fisiopatologia , Preparação de Coração Isolado , Masculino , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Transdução de Sinais , Fatores de TempoRESUMO
BACKGROUND: Conduction disturbances are the most frequent complication of transcatheter aortic valve replacement (TAVR). However, no data exists regarding the outcomes of intraprocedural high-degree atrioventricular block (HAVB) or complete heart block (CHB) in patients without previous conduction disturbances. OBJECTIVES: The aim of this study was to evaluate the outcomes of intraprocedural-HAVB/CHB in patients without previous intraventricular conduction disturbances. METHODS: The occurrence of intraprocedural-HAVB/CHB was assessed in 676 consecutive patients undergoing TAVR, and two groups were established according to its duration: persistent-HAVB/CHB (PHAVB/CHB) and transient-HAVB/CHB (THAVB/CHB), not present at the end of the procedure. RESULTS: Intraprocedural-HAVB/CHB occurred in 50 patients (7.4%), being persistent in 32 (64.0%), and transient in 18 (36.0%). The use of Medtronic Corevalve Revalving System (MCRS) and a greater oversizing of the valve increased the risk of intraprocedural-HAVB/CHB (p < 0.001). Permanent pacemaker implantation (PPI) was more frequent in the PHAVB/CHB than in the THAVB/CHB group (96.9% vs. 33.3%; p < 0.001). At 1-month follow-up, the PHAVB/CHB group showed a 98% ventricular pacing rate (VPR) compared to 16% in the THAVB/CHB group (p < 0.001), and similar VPR were observed at 1-year follow-up (98% vs. 37%, p < 0.001). Left ventricular ejection fraction (LVEF) decreased at 1-year follow-up in patients with PHAVB/CHB (-3.9 ± 1.8%, p = 0.003). CONCLUSIONS: In TAVR recipients with no prior intraventricular conduction disturbances, intraprocedural-HAVB/CHB occurred in 7.4% of cases. HAVB/CHB was persistent in most cases and determined a high rate of PPI post-TAVR. Very high VPR at 1- and 12-month follow-up were observed, which in turn was associated with a negative effect on LVEF. These results support early PPI and close follow-up in patients developing intraprocedural-PHAVB/CHB.
Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/etiologia , Bloqueio Cardíaco/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Frequência Cardíaca , Humanos , Período Intraoperatório , Masculino , Marca-Passo Artificial , Quebeque , Recuperação de Função Fisiológica , Espanha , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
A 59-year-old female underwent a dual-chamber pacemaker implantation for intermittent complete heart block. A baseline electrocardiogram showed normal sinus rhythm with first-degree atrioventricular (AV) block and right bundle branch block. A His bundle lead placement was attempted. An intracardiac electrogram from the His bundle lead demonstrated atrial-His, and His-ventricular intervals were 186 and 110 ms, respectively. Pacing was performed from the His bundle lead with a decremental pacing output to assess for the His bundle capture threshold. However, there were no significant QRS morphology changes during the pacing. Is the His bundle captured? The tracing evaluation demonstrated the fascinating physiology of activation wavefront in His Purkinje system that could be applied in the use of conducting system pacing technologies.
Assuntos
Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/fisiopatologia , Eletrocardiografia , Feminino , Bloqueio Cardíaco/terapia , Humanos , Pessoa de Meia-Idade , Marca-Passo ArtificialRESUMO
An infant with transposition of the great arteries was paced for postoperative heart block (single-site, right ventricular [RV] epicardial). She developed severe left ventricular (LV) dysfunction and septal dyskinesis. Resynchronization was performed at the age of 4 with an LV epicardial lead and an RV septal endocardial lead. The endocardial lead was affixed to the interventricular septum, then tunneled through the RV free wall and attached to an abdominal pulse generator. QRS duration decreased (176 to 122 ms) and LV ejection fraction improved (26 to 61%) and remained stable for 8 years. We present a case of successful resynchronization in congenital heart disease using a transmural RV septal lead.
Assuntos
Terapia de Ressincronização Cardíaca/métodos , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Transposição dos Grandes Vasos/fisiopatologia , Criança , Feminino , Comunicação Interventricular/fisiopatologia , HumanosRESUMO
BACKGROUND: Small retrospective studies reported that left ventricular (LV) pacing is likely to preserve LV function in children with isolated congenital complete atrioventricular block (CCAVB). The aim of this study was to prospectively evaluate LV contractility and synchrony in a cohort of neonates/infants at pacemaker implantation and follow-up. METHODS: Patients with CCAVB who underwent LV pacing were evaluated with electrocardiogram and echocardiogram in a single-center, prospective study. Data were collected at implantation, at 1-month and every year of follow-up, up to 5 years. LV ventricular dimensions (diameters and volumes), systolic function (ejection fraction [EF] and global longitudinal strain [GLS]), and synchrony were evaluated. Data are reported as median (25th-75th centiles). RESULTS: Twenty consecutive patients with CCAVB underwent pacemaker implantation (12 single-chamber pacemaker [VVIR] and eight dual-chamber pacemaker [DDD]) with epicardial leads: 17 on the LV apex and three on the free wall. Age at implantation was 0.3 months (1 day-4.5 months). Patients showed good clinical status, normal LV dimensions, preserved systolic function, and synchrony at 60 (30-60) months follow-up. EF increased to normal values in patients with preimplantation EF <50%. Presence of antibodies and pacing mode (DDD vs VVIR) had no impact on the outcome. CONCLUSIONS: LV pacing preserved LV systolic function and synchrony in neonates and infants with CCAVB at 5-year follow-up. LV EF improved in patients with low preimplantation EF. Pacing mode or the presence of autoantibodies did not demonstrated an impact on LV contractility and synchrony.
Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia , Eletrocardiografia , Bloqueio Cardíaco/congênito , Sístole/fisiologia , Função Ventricular Esquerda/fisiologia , Pré-Escolar , Feminino , Seguimentos , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Humanos , Recém-Nascido , Masculino , Estudos Prospectivos , Fatores de TempoRESUMO
Chronic RV pacing may lead to pacing induced cardiomyopathy in some patients and results in a higher risk of development of LV systolic dysfunction, heart failure, mitral regurgitation and atrial fibrillation. His bundle pacing emerged as the most physiologic form of ventricular pacing. However, wide adoption of this technique in routine clinical practice is limited by higher capture thresholds at implant sometimes, lower R wave amplitudes, atrial over sensing and increased risk for late rise in pacing thresholds (resulting in the need for lead revisions). Some recent studies have focused on left bundle branch area pacing as a solution to these problems. In our study, we have compared left bundle branch area pacing (in 22 patients) with conventional right ventricular apical pacing (in 28 patients) who presented to us with conventional indications for pacemaker implantations in term of procedure and fluoroscopy time and short-term lead performance and left ventricular function. The results of our study showed that left bundle branch area pacing is associated with shortened QRS duration (22.36 ± 9.36 ms) and better LV function (higher left ventricular ejection fraction 64.00 ± 3.03 vs. 59.73 ± 6.73 with a p value of 0.013 and lower left ventricular diastolic internal diameter 4.58 ± 0.32 vs. 5.23 ± 0.40 cm with a p value of < 0.001) in comparison to right ventricular apical pacing. The total procedure time and fluoroscopy time was similar (63.15 ± 7.02 vs. 55.15 ± 6.16 min, p value 0.142 and 6.08 ± 1.42 vs. 5.06 ± 1.30 min, p value 0.332 respectively) in left bundle branch area pacing group. The results of this study indicate that left bundle branch area pacing may be an option for physiological pacing in patients requiring a high percentage of ventricular pacing.
Assuntos
Potenciais de Ação , Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/terapia , Frequência Cardíaca , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular DireitaRESUMO
Permanent pacemaker implantation (PPI) is a widely recognized complication associated with TAVI (incidence up to 20%). Smaller registries have identified several variables associated with PPI. The objective was to validate patient- and transcatheter aortic valve implantation (TAVI)-related procedural variables associated with PPI. We performed a retrospective analysis of patients from six European centers undergoing TAVI with the Edwards SAPIEN 3 prosthesis. Baseline variables and pre-procedural ECG characteristics and CT-scans were taken into account. Data for 1745 patients were collected; 191 (10.9%) required PPI after TAVI. The baseline variables pulmonary hypertension (OR 1.64; 95% CI 1.01-2.59), QRS duration > 117 ms (OR 2.58; 95% CI 1.73-3.84), right bundle branch block (RBBB; OR 5.14; 95% CI 3.39-7.72), left anterior hemi block (OR 1.92; 95% CI 1.19-3.02) and first-degree atrioventricular block (AVB, OR 1.63; 95%CI 1.05-2.46) were significantly associated with PPI. RBBB (OR 8.11; 95% CI 3.19-21.86) and first-degree AVB (OR 2.39; 95% CI 1.18-4.66) remained significantly associated in a multivariate analysis. Procedure-related variables included access site (TF; OR 1.97; 95% CI 1.07-4.05), implanted valve size (29 mm; OR 1.88; 95% CI 1.35-2.59), mean TAVI valve implantation depth below the annulus > 30% (OR 3.75; 95% CI 2.01-6.98). Patients receiving PPI had longer ICU stays and later discharges. Acute kidney injury stage 2/3 was more common in patients with PPI until discharge (15.2 vs. 3.1%; p = 0.007), but was not statistically significant thereafter. Further differences in outcomes at 30 days did not reach significance. The data will aid pre- and post-procedural patient management and prevent adverse long-term outcomes.Clinical Trial: NCT03497611.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Estimulação Cardíaca Artificial , Bloqueio Cardíaco/terapia , Frequência Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Europa (Continente) , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
Cardiac conduction disturbances are linked with arrhythmia development. The concept of safety factor (SF) has been derived to describe the robustness of conduction, but the usefulness of this metric has been constrained by several limitations. For example, due to the difficulty of measuring the necessary input variables, SF calculations have only been applied to synthetic data. Moreover, quantitative validation of SF is lacking; specifically, the practical meaning of particular SF values is unclear, aside from the fact that propagation failure (i.e., conduction block) is characterized by SFâ¯<â¯1. This study aims to resolve these limitations for our previously published SF formulation and explore its relationship to relevant electrophysiological properties of cardiac tissue. First, HL-1 cardiomyocyte monolayers were grown on multi-electrode arrays and the robustness of propagation was estimated using extracellular potential recordings. SF values reconstructed purely from experimental data were largely between 1 and 5 (up to 89.1% of sites characterized). This range is consistent with values derived from synthetic data, proving that the formulation is sound and its applicability is not limited to analysis of computational models. Second, for simulations conducted in 1-, 2-, and 3-dimensional tissue blocks, we calculated true SF values at locations surrounding the site of current injection for sub- and supra-threshold stimuli and found that they differed from values estimated by our SF formulation by <10%. Finally, we examined SF dynamics under conditions relevant to arrhythmia development in order to provide physiological insight. Our analysis shows that reduced conduction velocity (Θ) caused by impaired intrinsic cell-scale excitability (e.g., due to sodium current a loss-of-function mutation) is associated with less robust conduction (i.e., lower SF); however, intriguingly, Θ variability resulting from modulation of tissue scale conductivity has no effect on SF. These findings are supported by analytic derivation of the relevant relationships from first principles. We conclude that our SF formulation, which can be applied to both experimental and synthetic data, produces values that vary linearly with the excess charge needed for propagation. SF calculations can provide insights helpful in understanding the initiation and perpetuation of cardiac arrhythmia.
Assuntos
Arritmias Cardíacas/fisiopatologia , Fenômenos Eletrofisiológicos , Modelos Cardiovasculares , Contração Miocárdica/fisiologia , Potenciais de Ação/fisiologia , Animais , Arritmias Cardíacas/epidemiologia , Bloqueio Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Contração Miocárdica/genética , Miocárdio/metabolismo , Miocárdio/patologia , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/fisiologia , Condutividade TérmicaRESUMO
BACKGROUND: Postoperative heart block is common among patients undergoing surgery for infective endocarditis (IE). Limited data exists allowing cardiologists to predict who will require permanent pacemaker (PPM) implantation postoperatively. We aimed to determine the rate of postoperative PPM insertion, predictors for postoperative PPM, and describe PPM utilization and rates of device-related infection during follow-up. MATERIALS AND METHODS: A retrospective analysis was performed of 191 consecutive patients from a single institution who underwent cardiac surgery for IE between 2001 and 2017. Preoperative and operative predictors for postoperative PPM were evaluated using univariate and multivariate logistic regression. RESULTS: The rate of postoperative PPM implantation was 11% (17/154). The PPM group had more preoperative prolonged PR interval alone (33% vs 12%; P = .03), coexistent prolonged PR and QRS durations (13% vs 2%; P = .01), infection beyond the valve leaflets (82% vs 41%; P = .001), aortic root debridement (65% vs 23%; P = <.001), patch repair (47% vs 20%; P = .01), postoperative prolonged PR interval (50% vs 24%; P = .01), and prolonged QRS duration (47% vs 15%; P = .001). On multivariate analysis, infection beyond the valve leaflets emerged as an independent predictor for postoperative PPM (odds ratio, 1.94, 95% confidence interval, 1.14-3.28; P = .014). A reduction in PPM utilization was observed in five patients while eight patients continued to show significant ventricular pacing with no underlying rhythm at 12 months. There were no device-related infections. CONCLUSION: Postoperative PPM was required in 11% of patients undergoing surgery for IE over a 16-year period. Infection beyond the valve leaflet was an independent predictor for postoperative PPM insertion.
Assuntos
Estimulação Cardíaca Artificial , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Endocardite/cirurgia , Bloqueio Cardíaco/terapia , Frequência Cardíaca , Marca-Passo Artificial , Potenciais de Ação , Adulto , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , VitóriaRESUMO
Despite recent advances in the treatment of cardiac arrhythmia, the available options are still limited and associated with some complications. Induction of biological pacemakers via Tbx18 gene insertion in the heart tissue has been suggested as a promising therapeutic strategy for cardiac arrhythmia. Following a previous in vitro study reporting the production of Tbx18-expressing human induced pluripotent stem cell-derived cardiomyocytes (hiPS-CMs), we aimed to investigate the efficacy of these engineered cells to generate pacemaker rhythms in a murine model of complete heart block. We also attempted to generate a functional pacemaker by Tbx18 overexpression in native cardiac cells of rat heart. The hiPSC-derived pacemaker cells were produced by lentiviral delivery of Tbx18 gene to stem cells during a small molecule-based differentiation process. In the present study, 16 male albino Wistar rats were randomly assigned to Tbx18-lentivirus (n = 4) and Tbx18-pacemaker cells (n = 4) administered via injection into the left ventricular anterolateral wall. The control rats received GFP-lentiviruses (n = 4) and GFP-pacemaker cells (n = 4). Fourteen days after the injection, the rats were sacrificed and analyzed by electrocardiography (ECG) recording using a Langendorff-perfused heart model following complete heart block induced by hypokalemia and crashing. Immunofluorescence staining was used to investigate the expression of Tbx18, HCN4 and connexin 43 (Cx43) proteins in Tbx18-delivered cells of heart tissues. The heart rate was significantly reduced after complete heart block in all of the experimental rats (P < 0.05). Heart beating in the Tbx18-transduced hearts was slower compared with rats receiving Tbx18-pacemaker cells (P = 0.04). The duration of ventricular fibrillation (VF) was higher in the lentiviral Tbx18 group compared with the GFP-injected controls (P = 0.02) and the Tbx18-pacemaker cell group (P = 0.02). The ECG recording data showed spontaneous pacemaker rhythms in both intervention groups with signal propagation in Tbx18-transduced ventricles. Immunostaining results confirmed the overexpression of HCN4 and downregulation of Cx43 as a result of the expression of the Tbx18 gene and spontaneously contracting myocyte formation. We confirmed the formation of a functional pacemaker after introduction of Tbx18 via cell and gene therapy strategies. Although the pacemaker activity was better in gene-received hearts since there were longer VF duration and signal propagation from the injection site, more data should be gathered from the long-term activity of such pacemakers in different hosts.
Assuntos
Técnicas de Transferência de Genes , Engenharia Genética , Bloqueio Cardíaco/terapia , Células-Tronco Pluripotentes Induzidas/citologia , Miócitos Cardíacos/citologia , Miócitos Cardíacos/transplante , Proteínas com Domínio T/genética , Animais , Diferenciação Celular , Modelos Animais de Doenças , Vetores Genéticos/genética , Bloqueio Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Lentivirus/genética , Masculino , Miócitos Cardíacos/metabolismo , Ratos , Ratos WistarRESUMO
OBJECTIVES: Assuming that autoimmune congenital heart block (CHB) is a progressive disease amenable to therapeutic modulation, we introduced a surveillance program for at-risk pregnancies with the dual aim of investigating if fetal atrioventricular block (AVB) could be detected and treated before becoming complete and irreversible, and to establish the incidence of AVB I, II and III in a large prospective cohort. METHODS: This was a prospective study of 212 anti-Ro52 antibody-exposed pregnancies at risk of fetal AVB that were followed weekly between 18 and 24 weeks' gestation at our tertiary fetal cardiology center from 2000 to 2015. A 12-lead electrocardiogram (ECG) was recorded within 1 week after birth. Fetal Doppler atrioventricular (AV) intervals were converted to Z-scores using reference standard values derived from normal pregnancies. Each fetus was represented by the average value of the two recordings, obtained at two consecutive visits, which resulted in the longest AV interval. AV interval values were classified into normal AV conduction (Z-score ≤ 2.0) and three levels of delayed AV conduction: Z-score > 2.0 and ≤ 3.0, Z-score > 3.0 and ≤ 4.0, and Z-score > 4.0. RESULTS: AVB II or III developed in 6/204 (2.9%) pregnancies without a CHB history and 1/8 (12.5%) of those with a CHB history. AV intervals > 2 and ≤ 3, > 3 and ≤ 4, and > 4 were detected in 16.0%, 7.5% and 2.8% of cases, respectively, and were related to the PR interval on 185 available ECGs. Three of the five cases with AVB III and one of two cases with 2:1 AVB II developed within 1 week of AV interval Z-score of 1.0, 1.9, 2.8 and 1.9, respectively. Transplacental treatment with betamethasone was associated with restoration of 1:1 AV conduction in the two fetuses with AVB II, with a better long-term result (normal ECG vs AVB I or II) observed in the case in which treatment was started within 1 week after AVB developed. Betamethasone treatment did not reverse AVB III, although a temporary effect on AV conduction was observed in 1/5 cases. Notably, the three cases in which treatment was started within 1 week after AVB III development responded with a higher ventricular rate than the other two cases and did not require pacemaker implantation until a later age (2-5 years vs 1.5-2 months). CONCLUSION: Fetal AV interval is a poor predictor of CHB progression, but CHB surveillance still allows detection of fetuses with AVB II or III shortly after its development, allowing for timely treatment initiation and potentially better outcome. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Assuntos
Bloqueio Atrioventricular/prevenção & controle , Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Feto/diagnóstico por imagem , Bloqueio Cardíaco/congênito , Bloqueio Atrioventricular/classificação , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/fisiopatologia , Autoanticorpos , Doenças Autoimunes/sangue , Doenças Autoimunes/tratamento farmacológico , Betametasona/administração & dosagem , Betametasona/uso terapêutico , Ecocardiografia Doppler/métodos , Feminino , Coração Fetal/fisiopatologia , Feto/patologia , Idade Gestacional , Glucocorticoides/administração & dosagem , Glucocorticoides/uso terapêutico , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/imunologia , Bloqueio Cardíaco/fisiopatologia , Humanos , Incidência , Lactente , Recém-Nascido , Gravidez/sangue , Gravidez/imunologia , Estudos Prospectivos , Resultado do TratamentoRESUMO
A 67-year-old female presented with history of recurrent palpitations. During one of the episodes of palpitation, a narrow QRS tachycardia was recorded and it was reported to be terminated with intravenous adenosine. The 12-lead electrocardiogram (ECG) showed no manifest ventricular preexcitation. ECG was within normal limits. The patient underwent an electrophysiology study after informed consent. She was taking calcium channel blockers and that was stopped five half-lives prior to the procedure. As catheters were being placed, a narrow QRS tachycardia got induced. During the study, there was development of right bundle branch block during the tachycardia. What is the mechanism of the tachycardia?
Assuntos
Eletrocardiografia/métodos , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Idoso , Diagnóstico Diferencial , Feminino , HumanosRESUMO
BACKGROUND: Various electrocardiographic abnormalities, including atrioventricular conduction block, have been reported in patients with myocarditis. We performed an observation study to describe the characteristics and outcomes of inpatients diagnosed with myocarditis complicated by heart block (HB) in a large national cohort. METHODS: We identified patients with primary ICD-9 codes for myocarditis HB from the Nationwide Inpatient Sample (NIS) Database from 1998 to 2013. We compared the baseline characteristics and compared clinical outcomes between patients with and without HB, and in patients with/without high degree atrioventricular block (HDAVB). RESULTS: From the NIS database, 31,760 patients had a principal diagnosis of myocarditis and HB was reported in 1.7% of these patients (n=540). Female gender and Asian race were independently associated with HB. Out of 540 patients, 363 patients had HDAVB (67.2%) and 177 patients had not advanced HB (32.8%). Not advanced HB was not associated with an increased mortality rate compared to patients without HB (0% vs. 2.7%, p=0.315). On the other hand, the incidence of cardiogenic shock, respiratory failure and renal failure were higher in patients with HDAVB (26.2% vs. 5.0%, 33.9% vs. 5.9% and 29.2% vs. 5.5%, p<0.001 respectively). Patients with HDAVB required more procedural support (incidence of intra-aortic balloon pump 17.8% vs. 3.3%). They also had significantly longer lengths of hospital stay (9.4±9.4 vs. 4.3±8.4, p<0.001) and higher mortality (15.5% vs. 2.7%, p<0.001). Compared to myocarditis patients without HB, the odds for mortality in myocarditis patients with HDAVB 1.58 (95% CI=1.03-2.49, p=0.039). CONCLUSIONS: The incidence of HB and HDAVB among patients with acute myocarditis was 1.7% and 1.1% respectively. Female gender and Asian race were both independently associated with significant odds for the occurrence of HB and HDAVB. High degree atrioventricular block was independently associated with increased morbidity and mortality.