RESUMO
Candida albicans is a leading cause of intravascular catheter-related infections. The capacity for biofilm formation has been proposed to contribute to the persistence of this fungal pathogen on catheter surfaces. While efforts have been devoted to identifying microbial factors that modulate C. albicans biofilm formation in vitro, our understanding of the host factors that may shape C. albicans persistence in intravascular catheters is lacking. Here, we used multiphoton microscopy to characterize biofilms in intravascular catheters removed from candidiasis patients. We demonstrated that, NETosis, a type of neutrophil cell death with antimicrobial activity, was implicated in the interaction of immune cells with C. albicans in the catheters. The catheter isolates exhibited reduced filamentation and candidalysin gene expression, specifically in the total parenteral nutrition culture environment. Furthermore, we showed that the ablation of candidalysin expression in C. albicans reduced NETosis and conferred resistance to neutrophil-mediated fungal biofilm elimination. Our findings illustrate the role of neutrophil NETosis in modulating C. albicans biofilm persistence in an intravascular catheter, highlighting that C. albicans can benefit from reduced virulence expression to promote its persistence in an intravascular catheter.
Assuntos
Biofilmes , Candida albicans , Candidíase , Infecções Relacionadas a Cateter , Armadilhas Extracelulares , Proteínas Fúngicas , Neutrófilos , Humanos , Biofilmes/crescimento & desenvolvimento , Proteínas Fúngicas/metabolismo , Candidíase/microbiologia , Candidíase/imunologia , Infecções Relacionadas a Cateter/microbiologia , Neutrófilos/imunologia , Neutrófilos/metabolismo , Armadilhas Extracelulares/imunologia , Catéteres/microbiologia , Regulação Fúngica da Expressão GênicaRESUMO
Multidrug-resistant Acinetobacter baumannii infections are an urgent clinical problem and can cause difficult-to-treat nosocomial infections. During such infections, like catheter-associated urinary tract infections (CAUTI), A. baumannii rely on adhesive, extracellular fibers, called chaperone-usher pathway (CUP) pili for critical binding interactions. The A. baumannii uropathogenic strain, UPAB1, and the pan-European subclone II isolate, ACICU, use the CUP pili Abp1 and Abp2 (previously termed Cup and Prp, respectively) in tandem to establish CAUTIs, specifically to facilitate bacterial adherence and biofilm formation on the implanted catheter. Abp1 and Abp2 pili are tipped with two domain tip adhesins, Abp1D and Abp2D, respectively. We discovered that both adhesins bind fibrinogen, a critical host wound response protein that is released into the bladder upon catheterization and is subsequently deposited on the catheter. The crystal structures of the Abp1D and Abp2D receptor-binding domains were determined and revealed that they both contain a large, distally oriented pocket, which mediates binding to fibrinogen and other glycoproteins. Genetic, biochemical, and biophysical studies revealed that interactions with host proteins are governed by several critical residues in and along the edge of the binding pocket, one of which regulates the structural stability of an anterior loop motif. K34, located outside of the pocket but interacting with the anterior loop, also regulates the binding affinity of the protein. This study illuminates the mechanistic basis of the critical fibrinogen-coated catheter colonization step in A. baumannii CAUTI pathogenesis.
Assuntos
Acinetobacter baumannii , Infecções Urinárias , Humanos , Adesinas Bacterianas/genética , Adesinas Bacterianas/metabolismo , Infecções Urinárias/microbiologia , Catéteres , Acinetobacter baumannii/genética , Fibrinogênio/metabolismoRESUMO
BACKGROUND: Despite the ubiquitous utilization of central venous catheters in clinical practice, their use commonly provokes thromboembolism. No prophylactic strategy has shown sufficient efficacy to justify routine use. Coagulation factors FXI (factor XI) and FXII (factor XII) represent novel targets for device-associated thrombosis, which may mitigate bleeding risk. Our objective was to evaluate the safety and efficacy of an anti-FXI mAb (monoclonal antibody), gruticibart (AB023), in a prospective, single-arm study of patients with cancer receiving central line placement. METHODS: We enrolled ambulatory cancer patients undergoing central line placement to receive a single dose of gruticibart (2 mg/kg) administered through the venous catheter within 24 hours of placement and a follow-up surveillance ultrasound at day 14 for evaluation of catheter thrombosis. A parallel, noninterventional study was used as a comparator. RESULTS: In total, 22 subjects (n=11 per study) were enrolled. The overall incidence of catheter-associated thrombosis was 12.5% in the interventional study and 40.0% in the control study. The anti-FXI mAb, gruticibart, significantly prolonged the activated partial thromboplastin time in all subjects on day 14 compared with baseline (P<0.001). Gruticibart was well tolerated and without infusion reactions, drug-related adverse events, or clinically relevant bleeding. Platelet flow cytometry demonstrated no difference in platelet activation following administration of gruticibart. T (thrombin)-AT (antithrombin) and activated FXI-AT complexes increased following central line placement in the control study, which was not demonstrated in our intervention study. CRP (C-reactive protein) did not significantly increase on day 14 in those who received gruticibart, but it did significantly increase in the noninterventional study. CONCLUSIONS: FXI inhibition with gruticibart was well tolerated without any significant adverse or bleeding-related events and resulted in a lower incidence of catheter-associated thrombosis on surveillance ultrasound compared with the published literature and our internal control study. These findings suggest that targeting FXI could represent a safe intervention to prevent catheter thrombosis. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04465760.
Assuntos
Neoplasias , Trombose , Humanos , Fator XI/metabolismo , Estudos Prospectivos , Trombose/etiologia , Trombose/prevenção & controle , Trombose/tratamento farmacológico , Hemorragia/induzido quimicamente , Catéteres/efeitos adversos , Neoplasias/tratamento farmacológico , Neoplasias/complicaçõesRESUMO
Healthcare-associated infections are major causes of complications that lead to extended hospital stays and significant medical costs. The use of medical devices, including catheters, increases the risk of bacterial colonization and infection through the presence of a foreign surface. Two outcomes are observed for catheterized patients: catheter-associated asymptomatic bacteriuria and catheter-associated urinary tract infection (CAUTI). However, the relationship between these two events remains unclear. To understand this relationship, we studied a murine model of Pseudomonas aeruginosa CAUTI. In this model, we also observe two outcomes in infected animals: acute symptoms that is associated with CAUTI and chronic colonization that is associated with asymptomatic bacteriuria. The timing of the acute outcome takes place in the first week of infection, whereas chronic colonization occurs in the second week of infection. We further showed that mutants lacking genes encoding type III secretion system (T3SS), T3SS effector proteins, T3SS injection pore, or T3SS transcriptional activation all fail to cause acute symptoms of CAUTI. Nonetheless, all mutants defective for T3SS colonized the catheter and bladders at levels similar to the parental strain. In contrast, through induction of the T3SS master regulator ExsA, all infected animals showed acute phenotypes with bacteremia. Our results demonstrated that the acute symptoms, which are analogous to CAUTI, and chronic colonization, which is analogous to asymptomatic bacteriuria, are independent events that require distinct bacterial virulence factors. Experimental delineation of asymptomatic bacteriuria and CAUTI informs different strategies for the treatment and intervention of device-associated infections.
Assuntos
Bacteriúria , Infecções Urinárias , Camundongos , Animais , Pseudomonas aeruginosa/genética , Bacteriúria/complicações , Infecções Urinárias/microbiologia , Sistemas de Secreção Tipo III , Catéteres/efeitos adversosRESUMO
SIGNIFICANCE STATEMENT: The Advancing American Kidney Health Initiative aims to increase rates of utilization of peritoneal dialysis (PD) in the United States. One of the first steps to PD is successful catheter placement, which can be performed by surgeons, interventional radiologists, or nephrologists. We examined the association between operator subspecialty and risk of needing a follow-up procedure in the first 90 days after initial PD catheter implantation. Overall, we found that 15.5% of catheters required revision, removal, or a second catheter placement within 90 days. The odds of requiring a follow-up procedure was 36% higher for interventional radiologists and 86% higher for interventional nephrologists compared with general surgeons. Further research is needed to understand how to optimize the function of catheters across different operator types. BACKGROUND: The US government has implemented incentives to increase the use of PD. Successful placement of PD catheters is an important step to increasing PD utilization rates. Our objective was to compare initial outcomes after PD catheter placement by different types of operators. METHODS: We included PD-naïve patients insured by Medicare who had a PD catheter inserted between 2010 and 2019. We examined the association between specialty of the operator (general surgeon, vascular surgeon, interventional radiologist, or interventional nephrologist) and odds of needing a follow-up procedure, which we defined as catheter removal, replacement, or revision within 90 days of the initial procedure. Mixed logistic regression models clustered by operator were used to examine the association between operator type and outcomes. RESULTS: We included 46,973 patients treated by 5205 operators (71.1% general surgeons, 17.2% vascular surgeons, 9.7% interventional radiologists, 2.0% interventional nephrologists). 15.5% of patients required a follow-up procedure within 90 days of the initial insertion, of whom 2.9% had a second PD catheter implanted, 6.6% underwent PD catheter removal, and 5.9% had a PD catheter revision within 90 days of the initial insertion. In models adjusted for patient and operator characteristics, the odds of requiring a follow-up procedure within 90 days were highest for interventional nephrologists (HR, 1.86; 95% confidence interval [CI], 1.56 to 2.22) and interventional radiologists (odds ratio, 1.36; 95% CI, 1.17 to 1.58) followed by vascular surgeons (odds ratio, 1.06; 95% CI, 0.97 to 1.14) compared with general surgeons. CONCLUSIONS: The probability of needing a follow-up procedure after initial PD catheter placement varied by operator specialty and was higher for interventionalists and lowest for general surgeons.
Assuntos
Diálise Peritoneal , Cirurgiões , Humanos , Idoso , Estados Unidos/epidemiologia , Nefrologistas , Medicare , Catéteres , Diálise Peritoneal/métodos , Radiologistas , Cateteres de Demora/efeitos adversosRESUMO
BACKGROUND: Use of mixed-oil (MO) intravenous fat emulsion (IFE) was shown to inhibit Candida albicans biofilm formation and overall rate of catheter-related bloodstream infections (CR-BSIs) compared with soybean-oil (SO) IFE). We aimed to delineate this inhibitory mechanism and impact of IFE choice on distribution of fungal CR-BSIs. METHODS: Transcriptional profiling was conducted on C. albicans grown in SO-IFE, MO-IFE, or SO-IFE with capric acid. Overexpression strains of shared down-regulated genes were constructed using a tetracycline-off system to assess hypha and biofilm formation in IFEs. A 5-year retrospective multicenter cohort study was performed to assess differences in CR-BSIs caused by Candida species based on the IFE formulation received in pediatric patients. RESULTS: Genes significantly down-regulated in MO-IFE and SO-IFE with capric acid included CDC11, HGC1, and UME6. Overexpression of HGC1 or UME6 enabled filamentation in capric acid and MO-IFE. Interestingly, only overexpression of UME6 was sufficient to rescue biofilm growth in MO-IFE. MO-IFE administration was associated with a higher proportion of non-albicans Candida versus C. albicans CR-BSIs (42% vs 33%; odds ratio, 1.22 [95% confidence interval, .46-3.26]). CONCLUSIONS: MO-IFE affects C. albicans biofilm formation and hyphal growth via a UME6-dependent mechanism. A numerical but not statistically significant difference in distribution of Candida spp. among CR-BSIs was observed.
Delivery of carbohydrates, amino acids, and lipids via intravenous catheters is necessary for some patients to supply daily caloric needs. These nutrient-dense parenteral solutions can promote microbial biofilm growth on the catheter surface, which may seed subsequent catheter-related bloodstream infection (CR-BSI). In fact, receipt of parenteral nutrition is an established risk factor for CR-BSI caused by the polymorphic fungal pathogen Candida albicans. New intravenous fat emulsions (IFEs) have gained market share and IFEs containing capric acid (mixed-oil [MO] IFE) compared with those without (soybean-oil [SO] IFE) impair the C. albicans yeast-to-hypha switcha trait strongly associated with pathogenicity and biofilm formation. In this study, we found that MO-IFE and capric acid reduced expression of a transcriptional regulator involved in hyphal extension (UME6) and down-regulated genes involved in cell partitioning (HGC1). Overexpression of these genes enabled hyphal growth in MO-IFE. Secondly, we sought to determine whether the type of IFE administered was associated with the clinical incidence of CR-BSIs caused by C. albicans or other common non-albicans Candida species. There was a nonsignificant numerical reduction in C. albicans infections in patients administered MO-IFE compared with SO-IFE. Collectively, this work shows that IFEs differentially affect Candida biology with potential infectious consequences for the patient.
Assuntos
Candida , Sepse , Humanos , Criança , Candida/genética , Emulsões Gordurosas Intravenosas , Estudos de Coortes , Candida albicans/genética , Biofilmes , Catéteres , HifasRESUMO
Pseudomonas aeruginosa is an opportunistic nosocomial pathogen responsible for a subset of catheter-associated urinary tract infections (CAUTI). In a murine model of P. aeruginosa CAUTI, we previously demonstrated that urea within urine suppresses quorum sensing and induces the Entner-Doudoroff (E-D) pathway. The E-D pathway consists of the genes zwf, pgl, edd, and eda. Zwf and Pgl convert glucose-6-phosphate into 6-phosphogluconate. Edd hydrolyzes 6-phosphogluconate to 2-keto-3-deoxy-6-phosphogluconate (KDPG). Finally, Eda cleaves KDPG to glyceraldehyde-3-phosphate and pyruvate, which enters the citric acid cycle. Here, we generated in-frame E-D mutants in the strain PA14 and assessed their growth phenotypes on chemically defined and complex media. These E-D mutants have a growth defect when grown on glucose or gluconate as the sole carbon source, which is similar to results previously reported for PAO1 mutants lacking E-D genes. RNA-sequencing following short exposure to urine revealed minimal gene regulation differences compared to the wild type. In a murine CAUTI model, virulence testing of E-D mutants revealed that two mutants lacking zwf and pgl showed minor fitness defects. Infection with the ∆pgl strain exhibited a 20% increase in host survival, and the ∆zwf strain displayed decreased colonization of the catheter and kidneys. Consequently, our findings suggest that the E-D pathway in P. aeruginosa is dispensable in this model of CAUTI. IMPORTANCE Prior studies have shown that the Entner-Doudoroff pathway is up-regulated when Pseudomonas aeruginosa is grown in urine. Pseudomonads use the Entner-Doudoroff (E-D) pathway to metabolize glucose instead of glycolysis, which led us to ask whether this pathway is required for urinary tract infection. Here, single-deletion mutants of each gene in the pathway were tested for growth on chemically defined media with single-carbon sources as well as complex media. The effect of each mutant on global gene expression in laboratory media and urine was characterized. The virulence of these mutants in a murine model of catheter-associated urinary tract infection revealed that these mutants had similar levels of colonization indicating that glucose is not the primary carbon source utilized in the urinary tract.
Assuntos
Gluconatos , Infecções por Pseudomonas , Infecções Urinárias , Animais , Camundongos , Pseudomonas aeruginosa/genética , Pseudomonas aeruginosa/metabolismo , Modelos Animais de Doenças , Glucose/metabolismo , Catéteres , CarbonoRESUMO
Studies suggest that central venous catheter bloodstream infections (BSIs) increased during the COVID-19 pandemic. We investigated catheter-related BSIs in Switzerland and found peripheral venous catheter (PVC) BSI incidence increased during 2021-2022 compared with 2020. These findings should raise awareness of PVC-associated BSIs and prompt inclusion of PVC BSIs in surveillance systems.
Assuntos
Bacteriemia , COVID-19 , Cateterismo Periférico , Infecção Hospitalar , Sepse , Humanos , Suíça/epidemiologia , Pandemias , Cateterismo Periférico/efeitos adversos , COVID-19/epidemiologia , COVID-19/complicações , Sepse/etiologia , Catéteres/efeitos adversos , Infecção Hospitalar/epidemiologia , Bacteriemia/epidemiologia , Bacteriemia/complicaçõesRESUMO
Dilated cardiomyopathy is conventionally defined as the presence of left ventricular or biventricular dilatation or systolic dysfunction in the absence of abnormal loading conditions (eg, primary valve disease) or significant coronary artery disease sufficient to cause ventricular remodelling. This definition has been recognised as overly restrictive, as left ventricular hypokinesis without dilation could be the initial presentation of dilated cardiomyopathy. The causes of dilated cardiomyopathy comprise genetic (primary dilated cardiomyopathy) or acquired factors (secondary dilated cardiomyopathy). Acquired factors include infections, toxins, cancer treatment, endocrinopathies, pregnancy, tachyarrhythmias, and immune-mediated diseases. 5-15% of patients with acquired dilated cardiomyopathy harbour a likely pathogenic or pathogenic gene variant (ie, gene mutation). Therefore, the diagnostic tests and therapeutic approach should always consider both genetic and acquired factors. This Seminar will focus on the current multidimensional diagnostic and therapeutic approach and discuss the underlying pathophysiology that could drive future treatments aiming to repair or replace the existing gene mutation, or target the specific inflammatory, metabolic, or pro-fibrotic drivers of genetic or acquired dilated cardiomyopathy.
Assuntos
Cardiomiopatia Dilatada , Doença da Artéria Coronariana , Feminino , Gravidez , Humanos , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/etiologia , Cardiomiopatia Dilatada/terapia , Causalidade , Catéteres , MutaçãoRESUMO
Gastrointestinal (GI) bleeding is the most common GI diagnosis leading to hospitalization within the United States. Prompt diagnosis and treatment of GI bleeding is critical to improving patient outcomes and reducing high health care utilization and costs. Radiologic techniques including CT angiography, catheter angiography, CT enterography, MR enterography, nuclear medicine red blood cell scan, and technetium-99m pertechnetate scintigraphy (Meckel scan) are frequently used to evaluate patients with GI bleeding and are complementary to GI endoscopy. However, multiple management guidelines exist, which differ in the recommended utilization of these radiologic examinations. This variability can lead to confusion as to how these tests should be used in the evaluation of GI bleeding. In this document, a panel of experts from the American College of Gastroenterology and Society of Abdominal Radiology provide a review of the radiologic examinations used to evaluate for GI bleeding including nomenclature, technique, performance, advantages, and limitations. A comparison of advantages and limitations relative to endoscopic examinations is also included. Finally, consensus statements and recommendations on technical parameters and utilization of radiologic techniques for GI bleeding are provided. © Radiological Society of North America and the American College of Gastroenterology, 2024. Supplemental material is available for this article. This article is being published concurrently in American Journal of Gastroenterology and Radiology. The articles are identical except for minor stylistic and spelling differences in keeping with each journal's style. Citations from either journal can be used when citing this article. See also the editorial by Lockhart in this issue.
Assuntos
Hemorragia Gastrointestinal , Radiologia , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia , CatéteresRESUMO
Soft millirobots have evolved into various therapeutic applications in the medical field, including for vascular dredging, cell transportation, and drug delivery, owing to adaptability to their surroundings. However, most soft millirobots cannot quickly enter, retrieve, and maintain operations in their original locations after removing the external actuation field. This study introduces a soft magnetic millirobot for targeted medicine delivery that can be transported into the body through a catheter and anchored to the tissues. The millirobot has a bilayer adhesive body with a mussel-inspired hydrogel layer and an octopus-inspired magnetic structural layer. It completes entry and retrieval with the assistance of a medical catheter based on the difference between the adhesion of the hydrogel layer in air and water. The millirobot can operate in multiple modes of motion under external magnetic fields and underwater tissue adhesion after self-unfolding with the structural layer. The adaptability and recyclability of the millirobots are demonstrated using a stomach model. Combined with ultrasound (US) imaging, operational feasibility within organisms is shown in isolated small intestines. In addition, a highly efficient targeted drug delivery is confirmed using a fluorescence imaging system. Therefore, the proposed soft magnetic millirobots have significant potential for medical applications.
Assuntos
Adesivos , Sistemas de Liberação de Medicamentos , Hidrogéis/química , Catéteres , Fenômenos MagnéticosRESUMO
OBJECTIVES: To examine whether an ultrasound-guided infraclavicular cannulation of the axillary artery is noninferior to an ultrasound-guided cannulation of the common femoral artery for arterial catheter placement in critically ill patients. DESIGN: Prospective, investigator-initiated, noninferiority randomized controlled trial. SETTING: University-affiliated ICU in Poland. PATIENTS: Mechanically ventilated patients with indications for arterial catheter placement. INTERVENTIONS: Patients were randomly assigned into two groups. In the axillary group (A group), an ultrasound-guided infraclavicular, in-plane cannulation of the axillary artery was performed. In the femoral group (F group), an ultrasound-guided, out-of-plane cannulation of the common femoral artery was performed. MEASUREMENTS AND MAIN RESULTS: A total of 1,079 mechanically ventilated patients were screened, of whom 110 were randomized. The main outcome was the cannulation success rate. The secondary outcomes included the artery puncture success rate, the first-pass success rate, number of attempts required to puncture, and the rate of early mechanical complications. The cannulation success rate in the A group and F group was 96.4% and 96.3%, respectively. The lower limit of 95% CI for the difference in cannulation success rate was above the prespecified noninferiority margin of-7% demonstrating noninferiority of infraclavicular approach. No significant differences were found between the groups in terms of puncture success rate and the rate of early mechanical complications. CONCLUSIONS: An ultrasound-guided infraclavicular cannulation of the axillary artery is noninferior to the cannulation of the common femoral artery in terms of procedure success rate. We found no significant differences in early mechanical complications between the groups.
Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Humanos , Artéria Axilar , Veia Axilar/diagnóstico por imagem , Cateterismo Venoso Central/métodos , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos , CatéteresRESUMO
PURPOSE: MR-guided cardiac catheterization procedures currently use passive tracking approaches to follow a gadolinium-filled catheter balloon during catheter navigation. This requires frequent manual tracking and repositioning of the imaging slice during navigation. In this study, a novel framework for automatic real-time catheter tracking during MR-guided cardiac catheterization is presented. METHODS: The proposed framework includes two imaging modes (Calibration and Runtime). The sequence starts in Calibration mode, in which the 3D catheter coordinates are determined using a stack of 10-20 contiguous saturated slices combined with real-time image processing. The sequence then automatically switches to Runtime mode, where three contiguous slices (acquired with partial saturation), initially centered on the catheter balloon using the Calibration feedback, are acquired continuously. The 3D catheter balloon coordinates are estimated in real time from each Runtime slice stack using image processing. Each Runtime stack is repositioned to maintain the catheter balloon in the central slice based on the prior Runtime feedback. The sequence switches back to Calibration mode if the catheter is not detected. This framework was evaluated in a heart phantom and 3 patients undergoing MR-guided cardiac catheterization. Catheter detection accuracy and rate of catheter visibility were evaluated. RESULTS: The automatic detection accuracy for the catheter balloon during the Calibration/Runtime mode was 100%/95% in phantom and 100%/97 ± 3% in patients. During Runtime, the catheter was visible in 82% and 98 ± 2% of the real-time measurements in the phantom and patients, respectively. CONCLUSION: The proposed framework enabled real-time continuous automatic tracking of a gadolinium-filled catheter balloon during MR-guided cardiac catheterization.
Assuntos
Cateterismo Cardíaco , Gadolínio , Humanos , Cateterismo Cardíaco/métodos , Catéteres , Imagens de Fantasmas , CoraçãoRESUMO
INTRODUCTION: High-power short-duration (HPSD) ablation at 50 W, guided by ablation index (AI) or lesion size index (LSI), and a 90 W/4 s very HSPD (vHPSD) setting are available for atrial fibrillation (AF) treatment. Yet, tissue temperatures during ablation with different catheters around venoatrial junction and collateral tissues remain unclear. METHODS: In this porcine study, we surgically implanted thermocouples on the epicardium near the superior vena cava (SVC), right pulmonary vein, and esophagus close to the inferior vena cava. We then compared tissue temperatures during 50W-HPSD guided by AI 400 or LSI 5.0, and 90 W/4 s-vHPSD ablation using THERMOCOOL SMARTTOUCH SF (STSF), TactiCath ablation catheter, sensor enabled (TacthCath), and QDOT MICRO (Qmode and Qmode+ settings) catheters. RESULTS: STSF produced the highest maximum tissue temperature (Tmax ), followed by TactiCath, and QDOT MICRO in Qmode and Qmode+ (62.7 ± 12.5°C, 58.0 ± 10.1°C, 50.0 ± 12.1°C, and 49.2 ± 8.4°C, respectively; p = .005), achieving effective transmural lesions. Time to lethal tissue temperature ≥50°C (t-T ≥ 50°C) was fastest in Qmode+, followed by TacthCath, STSF, and Qmode (4.3 ± 2.5, 6.4 ± 1.9, 7.1 ± 2.8, and 7.7 ± 3.1 s, respectively; p < .001). The catheter tip-to-thermocouple distance for lethal temperature (indicating lesion depth) from receiver operating characteristic curve analysis was deepest in STSF at 5.2 mm, followed by Qmode at 4.3 mm, Qmode+ at 3.1 mm, and TactiCath at 2.8 mm. Ablation at the SVC near the phrenic nerve led to sudden injury at t-T ≥ 50°C in all four settings. The esophageal adventitia injury was least deep with Qmode+ ablation (0.4 ± 0.1 vs. 0.8 ± 0.4 mm for Qmode, 0.9 ± 0.3 mm for TactiCath, and 1.1 ± 0.5 mm for STSF, respectively; p = .005), correlating with Tmax . CONCLUSION: This study revealed distinct tissue temperature patterns during HSPD and vHPSD ablations with the three catheters, affecting lesion effectiveness and collateral damage based on Tmax and/or t-T ≥ 50°C. These findings provide key insights into the safety and efficacy of AF ablation with these four settings.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Suínos , Animais , Temperatura , Veia Cava Superior/cirurgia , Catéteres , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Temperatura Alta , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
INTRODUCTION: The circular catheter compatible with current cryoballoon system for atrial fibrillation (AF) ablation is exclusively sensed by impedance-based electro-anatomical mapping (EAM) system, limiting the accuracy of maps. We aim to investigate the feasibility and safety of a magnetic-based circular mapping catheter for AF ablation with cryoballoon. METHODS: Nineteen consecutive patients who underwent pulmonary vein isolation (PVI) with cryoballoon for paroxysmal or persistent AF were included. EAMs of left atrium (LA) created by the LASSOSTAR™NAV catheter (Lassostar map) before and after PVI were compared to that generated by a high-density mapping catheter (Pentaray map) from different aspects including structural similarity, PV angle, LA posterior wall (LAPW) and low voltage areas (LVAs), and the amplitude of far field electrograms (FFEs) recorded by catheters. RESULTS: All patients had successful PVI without major complications. With similar mapping time and density, the LA volume calculated from the Pentaray map and Lassostar map were comparable. There were no significant differences in PV angle of all PVs and PW area (16.8 ± 3.2 vs. 17.1 ± 2.8, p = .516) between Pentaray map and Lassostar map. High structural similarity score was observed between two maps (0.783 in RAO/LAO view and 0.791 in PA view). Lassostar map detected lesser but not statistically significant extension of LVA (13.9% vs. 18.3%, p = .07). Amplitude of FFE was larger at the right superior PV on Lassostar map (0.21 ± 0.16 vs. 0.14 ± 0.11 mV, p = .041) compared to that on the Pentaray map. CONCLUSION: In our initial experience, PVI with cryoballoon and magnetic-based circular LASSOSTAR™NAV catheter was safe and effective based on the accurate LA geometry it created.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Resultado do Tratamento , Catéteres , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Fenômenos Magnéticos , RecidivaRESUMO
INTRODUCTION: Pulsed electric field (PEF) ablation relies on the intersection of a critical voltage gradient with tissue to cause cell death. Field-based lesion formation with PEF technologies may still depend on catheter-tissue contact (CTC). The purpose of this study was to assess the impact of CTC on PEF lesion formation with an investigational large area focal (LAF) catheter in a preclinical model. METHODS: PEF ablation via a 10-spline LAF catheter was used to create discrete right ventricle (RV) lesions and atrial lesion sets in 10 swine (eight acute, two chronic). Local impedance (LI) was used to assess CTC. Lesions were assigned to three cohorts using LI above baseline: no tissue contact (NTC: ≤∆10 Ω, close proximity to tissue), low tissue contact (LTC: ∆11-29 Ω), and high tissue contact (HTC: ≥∆30 Ω). Acute animals were infused with triphenyl tetrazolium chloride (TTC) and killed ≥2 h post-treatment. Chronic animals were remapped 30 days post-index procedure and stained with infused TTC. RESULTS: Mean (± SD) RV treatment sizes between LTC (n = 14) and HTC (n = 17) lesions were not significantly different (depth: 5.65 ± 1.96 vs. 5.68 ± 2.05 mm, p = .999; width: 15.68 ± 5.22 vs. 16.98 ± 4.45 mm, p = .737), while mean treatment size for NTC lesions (n = 6) was significantly smaller (1.67 ± 1.16 mm depth, 5.97 ± 4.48 mm width, p < .05). For atrial lesion sets, acute and chronic conduction block were achieved with both LTC (N = 7) and HTC (N = 6), and NTC resulted in gaps. CONCLUSIONS: PEF ablation with a specialized LAF catheter in a swine model is dependent on CTC. LI as an indicator of CTC may aid in the creation of consistent transmural lesions in PEF ablation.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Suínos , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Frequência Cardíaca , Ventrículos do Coração , Impedância Elétrica , Catéteres , Fibrilação Atrial/cirurgiaRESUMO
INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.
Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Catéteres , Eletrocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Septo Interventricular/diagnóstico por imagemRESUMO
INTRODUCTION: The aim of the current study was to elucidated the reliable atrial fibrillation (AF) drivers identified by CARTOFINDER using OctaRay catheter. METHODS AND RESULTS: The reliability of focal and rotational activations identified by CARTOFINDER using OctaRay catheter was assessed by the sequential recordings in each site of both atrium before and after pulmonary vein isolation (PVI) in 10 persistent AF patients. The outcome measures were the reproducibility rate during the sequential recordings and the stability rate between pre- and post-PVI as reliable focal and rotational activations. The study results were compared with those under use of PentaRay catheter (N = 18). Total 68928 points of 360 sites in OctaRay group and 24 177 points of 311 sites in PentaRay were assessed. More focal activation sites were identified in OctaRay group than PentaRay group (7.9% vs. 5.7%, p < .001), although the reproducibility rate and the stability rate were significantly lower in OctaRay group (45.3% vs. 58.9%, p < .001; 11.2% vs. 28.4%, p < .001). Meanwhile, the prevalence of reproducible focal activation sites among overall points was comparable (3.6% vs. 3.3%, p = .08). Regarding rotational activation, more rotational activation sites were identified in OctaRay group (5.1% vs. 0.2%, p < .001), and the reproducibility rate and the stability rate were significantly higher in OctaRay group (45.2% and 12.5% vs. 0.0%, p < .001). Both reliable focal and rotational activation sites were characterized by significantly shorter AF-cycle length (CL) and higher repetition of focal and rotational activations during the recordings compared with the sites of non or unreliable focal and rotational activations. CONCLUSION: In CARTOFINDER, OctaRay catheter could identify reliable focal activation with high resolution and reliable rotational activation compared with PentaRay catheter. The repetitive focal and rotational activations with short AF-CL could be the potential target during ablation.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Frequência Cardíaca , Reprodutibilidade dos Testes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Catéteres , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
Investigating the application of innovative antimicrobial surface coatings on medical devices is an important field of research. Many of these coatings have significant drawbacks, including biocompatibility, coating stability and the inability to effectively combat multiple drug-resistant bacteria. In this research, we developed an antibiofilm surface coating for medical catheters using biosynthesized silver nanoparticles (b-Cs-AgNPs) developed using leaves extract of Calliandra surinamensis. Various characterization techniques were employed to thoroughly characterize the synthesized b-Cs-AgNPs and c-AgNPs. b-Cs-AgNPs were compatible with human normal kidney cells and chicken embryos. It did not trigger any skin inflammatory response in in vivo rat model. b-Cs-AgNPs demonstrated potent zone of inhibition of 19.09 mm when subjected to the disc diffusion method in E. coli confirming strong antibacterial property. Different anti-bacterial assays including liquid growth curve, colony counting assay, biofilm formation assay supported the potent antimicrobial efficacy of b-Cs-AgNPs alone and when coated to medical grade catheters. Mechanistic studies reveal the presence of ferulic acid, that was important for the synthesis of b-AgNPs along with enhanced antibacterial effects of b-Cs-AgNPs compared to c-AgNPs, supported by molecular docking analysis. These results together demonstrated the effective role b-Cs-AgNPs in combating infections and mitigating biofilm formations, highlighting their need for further study in the field of biomedical applications.
Assuntos
Antibacterianos , Biofilmes , Catéteres , Nanopartículas Metálicas , Prata , Animais , Biofilmes/efeitos dos fármacos , Prata/química , Prata/farmacologia , Nanopartículas Metálicas/química , Antibacterianos/farmacologia , Antibacterianos/química , Antibacterianos/síntese química , Catéteres/microbiologia , Galinhas , Escherichia coli/efeitos dos fármacos , Escherichia coli/fisiologia , Testes de Sensibilidade Microbiana , Humanos , Embrião de Galinha , Ratos , Extratos Vegetais/farmacologia , Extratos Vegetais/química , Folhas de Planta/química , Folhas de Planta/microbiologiaRESUMO
PURPOSE: To assess the effects of a workflow for reproducible patient and breast positioning on implant stability during high-dose-rate multi-catheter breast brachytherapy. METHODS: Thirty patients were treated with our new positioning control workflow. Implant stability was evaluated based on a comparison of planning-CTs to control-CTs acquired halfway through the treatment. To assess geometric stability, button-button distance variations as well as Euclidean dwell position deviations were evaluated. The latter were also quantified within various separated regions within the breast to investigate the location-dependency of implant alterations. Furthermore, dosimetric variations to target volume and organs at risk (ribs, skin) as well as isodose volume changes were analyzed. Results were compared to a previously treated cohort of 100 patients. RESULTS: With the introduced workflow, the patient fraction affected by button-button distance variations >â¯5â¯mm and by dwell position deviations >â¯7â¯mm were reduced from 37% to 10% and from 30% to 6.6%, respectively. Implant stability improved the most in the lateral to medial breast regions. Only small stability enhancements were observed regarding target volume dosimetry, but the stability of organ at risk exposure became substantially higher. D0.2ccm skin dose variations >â¯12.4% and D0.1ccm rib dose variations >â¯6.7% were reduced from 11% to 0% and from 16% to 3.3% of all patients, respectively. CONCLUSION: Breast positioning control improved geometric and dosimetric implant stability for individual patients, and thus enhanced physical plan validity in these cases.