Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.052
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(6): 1078-1082, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38509774

RESUMO

INTRODUCTION: Percutaneous left atrial appendage occlusion (LAAO) is traditionally performed under general anesthesia with trans-esophageal echocardiography guidance. Intracardiac echo (ICE)-guided LAAO closure is increasing in clinical use. The ICE catheter is crossed into LA via interatrial septum (IAS) after the septum is dilated with LAAO delivery sheath. This step can be time-consuming and requires significant ICE catheter manipulation, which increases the risk of cardiac perforation. Pre-emptive septal balloon dilation can potentially help with ICE advancement in the LA. We sought to evaluate the effect of pre-dilation of the IAS with an 8 mm balloon on the ease of crossing the ICE catheter, fluoroscopy time for crossing, and overall procedure time. METHODS: The Piedmont LAAO registry was used to identify consecutive patients who underwent LAAO. The initial 25 patients in whom balloon dilation of the IAS was performed served as the experimental cohort, and the 25 consecutive patients before that in whom balloon dilation was not performed served as controls. In the experimental group, after a trans-septal puncture, the sheath was retracted to the right atrium with a guidewire still in the LA. An 8 × 40 mm Evercoss™ over the wire balloon was inflated across the IAS. The ICE catheter was then crossed into the LA using the fluoroscopic landmark of the guide wire and the ICE imaging. The sheath was then advanced along the ICE catheter via the transseptal puncture (TSP) and the procedure continued. Follow-up compputed tomography imaging was obtained at 4-8 weeks. RESULTS: Each group consisted of 25 patients. There were no significant differences in baseline characteristics. All procedures were performed successfully under conscious sedation and ICE guidance. There was a significant reduction in the overall procedure time, fluoroscopy time, and time for transseptal puncture to ICE in LA. There was no difference in the size of the acute residual interatrial shunt, as measured via ICE, or the size and presence of iatrogenic ASD at follow-up. CONCLUSION: Balloon dilation of TSP is safe and is associated with increased efficiency in ICE-guided LAAO procedures.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Sistema de Registros , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Masculino , Feminino , Idoso , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ultrassonografia de Intervenção , Fatores de Tempo , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Septo Interatrial/diagnóstico por imagem , Valor Preditivo dos Testes
2.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38468182

RESUMO

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Idoso , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Vasos Coronários/diagnóstico por imagem , Oclusão do Apêndice Atrial Esquerdo , Desenho de Prótese , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/etiologia
3.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584522

RESUMO

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Ultrassonografia de Intervenção , Humanos , Permeabilidade do Canal Arterial/terapia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Idade Gestacional , Valor Preditivo dos Testes , Masculino , Feminino , Fatores de Tempo , Índice de Gravidade de Doença , Recém-Nascido Prematuro , Lactente Extremamente Prematuro , Unidades de Terapia Intensiva Neonatal , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Dispositivo para Oclusão Septal , Lactente
4.
Catheter Cardiovasc Interv ; 103(6): 1050-1061, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38363035

RESUMO

INTRODUCTION: Right-side infective endocarditis (RSIE) is caused by microorganisms and develops into intracardiac and extracardiac complications with high in-hospital and 1-year mortality. Treatments involve antibiotic and surgical intervention. However, those presenting with extremes e.g. heart failure, or septic shock who are not ideal candidates for conventional medical therapy might benefit from minimally invasive procedures. OBJECTIVE: This review summarizes existing observational studies that reported minimally invasive procedures to debulk vegetation due to infective endocarditis either on valve or cardiac implantable electronic devices. METHODS: A targeted literature review was conducted to identify studies published in PubMed/MEDLINE, EMBASE, and Cochrane Central Database from January 1, 2015 to June 5, 2023. The efficacy and/or effectiveness of minimally invasive procedural interventions to debulk vegetation due to RSIE were summarized following PRISMA guidelines. RESULTS: A total of 11 studies with 208 RSIE patients were included. There were 9 studies that assessed the effectiveness of the AngioVac system and 2 assessed the Penumbra system. Overall procedure success rate was 87.9%. Among 8 studies that reported index hospitalization, 4 studies reported no death, while the other 4 studies reported 10 deaths. CONCLUSIONS: This study demonstrates that multiple systems can provide minimally invasive procedure options for patients with RSIE with high procedural success. However, there are mixed results regarding complications and mortality rates. Further large cohort studies or randomized clinical trials are warranted to assess and/or compare the efficacy and safety of these systems.


Assuntos
Endocardite Bacteriana , Humanos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Estudos Observacionais como Assunto , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Fatores de Risco , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38695165

RESUMO

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Assuntos
Cateterismo Cardíaco , Cateteres Cardíacos , Insuficiência da Valva Mitral , Valva Mitral , Punções , Humanos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Septos Cardíacos/cirurgia , Septos Cardíacos/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38662126

RESUMO

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Valor Preditivo dos Testes , Desenho de Prótese , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Masculino , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Estudos Retrospectivos , Incidência , Tomografia Computadorizada por Raios X , Tomografia Computadorizada Multidetectores
7.
Catheter Cardiovasc Interv ; 103(7): 1148-1151, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639161

RESUMO

The transcatheter edge-to-edge mitral valve repair (TEER) has been recommended as a reliable treatment option for selected patients with severe degenerative and functional mitral regurgitation (MR). Although MR patients with rheumatic etiology were excluded from two significant trials (EVEREST II and COAPT) that established a role for the TEER in degenerative and functional MR. However, it has been reported that the TEER procedure could be safely and effectively performed in carefully selected rheumatic MR patients. Therefore, we share a case report of successfully treating severe rheumatic MR using a novel-designed TEER system (JensClipTM).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Cardiopatia Reumática , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/etiologia , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/cirurgia , Cardiopatia Reumática/fisiopatologia , Cardiopatia Reumática/terapia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Feminino , Ecocardiografia Transesofagiana , Ecocardiografia Doppler em Cores , Desenho de Prótese , Próteses Valvulares Cardíacas , Pessoa de Meia-Idade , Masculino
8.
Catheter Cardiovasc Interv ; 103(7): 1152-1155, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38606476

RESUMO

The use of left atrial appendage occlusion (LAAO) devices have gained prominence as an alternative to long-term anticoagulation therapy in patients with atrial fibrillation at risk of stroke and high risk of bleeding. While these devices have shown efficacy in reducing stroke risk, there have been reported cases of embolization of the Watchman device. There are very few cases of successful percutaneous retrieval of embolized Watchman devices from the left ventricle (LV), as many of these cases require open heart surgery for safe removal. We are presenting a case of an 80-year-old male whose Watchman device embolized to the LV and was entrapped on the LV papillary muscle that was then successfully retrieved via percutaneous methods, which shows the percutaneous options remain a viable strategy to retrieve LAAO devices from the LV.


Assuntos
Fibrilação Atrial , Cateterismo Cardíaco , Remoção de Dispositivo , Migração de Corpo Estranho , Músculos Papilares , Humanos , Masculino , Idoso de 80 Anos ou mais , Resultado do Tratamento , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Migração de Corpo Estranho/terapia , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/diagnóstico por imagem , Músculos Papilares/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Embolia/etiologia , Embolia/diagnóstico por imagem , Embolia/terapia , Embolia/diagnóstico , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Ecocardiografia Transesofagiana
9.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597297

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Assuntos
Cateterismo Cardíaco , Análise de Elementos Finitos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Medição de Risco , Adolescente , Resultado do Tratamento , Fatores de Risco , Masculino , Criança , Estudos Retrospectivos , Feminino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Adulto Jovem , Valor Preditivo dos Testes , Hemodinâmica , Stents , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Tomada de Decisão Clínica , Adulto
10.
Catheter Cardiovasc Interv ; 103(7): 1159-1164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639138

RESUMO

Despite progressively uncommon in Western countries, rheumatic heart disease still portrays a significant global burden. In elderly or high-surgical risk patients, plurivalvular disease may require a complex percutaneous approach. Transcatheter aortic valve implantation (TAVI) in patients with previous monoleaflet mitral prosthesis is challenging due to interference between the aortic valve and the rigid mitral mechanical prosthesis "ring." Prior cases report the use of CoreValve or Edwards Sapien aortic valves in patients with adequate mitro-aortic distance. Performing a second major procedure, such as tricuspid valve-in-valve (TVIV), sequentially during a single percutaneous intervention, increases treatment complexity. An 83-year-old woman with rheumatic heart disease, with previous implantation of a Bjork-Shiley monoleaflet mitral prosthesis, and Carpentier-Edwards 29 tricuspid bioprosthesis presented with decompensated heart failure due to severe aortic stenosis and tricuspid bioprosthesis stenosis. After HeartTeam discussion, the patient was deemed as inoperable due to a prohibitive surgical risk. As an alternative, a TAVI (Navitor FlexNav) and a transcatheter TVIV replacement (Edwards Sapiens 3 Ultra) were discussed and proposed, with both techniques being performed sequentially in a single procedure. TAVI in a patient with a previous monoleaflet mitral mechanical prosthesis and TVIV may be a feasible approach in inoperable patients with plurivalvular disease.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Desenho de Prótese , Cardiopatia Reumática , Substituição da Valva Aórtica Transcateter , Valva Tricúspide , Humanos , Feminino , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/fisiopatologia , Cardiopatia Reumática/cirurgia , Cardiopatia Reumática/terapia , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Recuperação de Função Fisiológica , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico por imagem
11.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38639143

RESUMO

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Assuntos
Técnicas de Ablação , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica , Etanol , Implante de Prótese de Valva Cardíaca , Valva Mitral , Humanos , Estudos Retrospectivos , Masculino , Etanol/administração & dosagem , Etanol/efeitos adversos , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/mortalidade , Cardiomiopatia Hipertrófica/terapia , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/fisiopatologia , Feminino , Resultado do Tratamento , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/mortalidade , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Pessoa de Meia-Idade , Fatores de Risco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Tempo , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Recuperação de Função Fisiológica , Idoso de 80 Anos ou mais , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade
12.
BMC Cardiovasc Disord ; 24(1): 293, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844866

RESUMO

Patients with previous interatrial shunt device (IASD) implantation may face greater challenges during future left atrial interventional procedures. Herein, we report the first case of left atrial appendage closure (LAAC) in a patient with previous IASD implantation. The patient successfully underwent LAAC using the LAmbre device without complications.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Masculino , Feminino , Ecocardiografia Transesofagiana , Idoso , Função do Átrio Esquerdo , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Forame Oval Patente/fisiopatologia , Forame Oval Patente/cirurgia , Oclusão do Apêndice Atrial Esquerdo
13.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872098

RESUMO

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Valva Pulmonar , Recuperação de Função Fisiológica , Humanos , Masculino , Criança , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Adolescente , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Fatores de Tempo , Adulto , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Bioprótese , Estenose da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Sudeste Asiático
14.
Curr Cardiol Rep ; 26(6): 459-474, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38884853

RESUMO

PURPOSE OF REVIEW: Patients with severe tricuspid regurgitation (TR) are at risk for significant morbidity and mortality. Transcatheter tricuspid valve interventions (TTVI) may offer patients less invasive treatment alternatives to surgery. This review evaluates the most common class of device currently used worldwide to treat TR, tricuspid transcatheter edge-to-edge repair (T-TEER) and orthotopic transcatheter tricuspid valve replacement (TTVR), both of which are now approved in the USA and Europe. RECENT FINDINGS: The first pivotal randomized clinical trial, TRILUMINATE, demonstrated that T-TEER can safely reduce TR and is associated with improved health status outcomes. However, results of this trial have raised questions about whether this device can provide sufficient TR reduction to impact clinical outcomes. Orthotopic TTVR has recently gained attention with initial data suggesting near-complete TR elimination. The current review examines the technical features and anatomic limitations of the most commonly used devices for T-TEER and orthotopic TTVR, discusses the current clinical data for these devices, and offers a theoretical construct for device selection.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentação , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
15.
J Formos Med Assoc ; 123(5): 600-605, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38238125

RESUMO

BACKGROUND: The diameter and shape of the left atrial appendage (LAA) orifices may influence occluder selection and the outcomes of left atrial appendage closure (LAAC) procedure. This study aimed to evaluate the impact of LAA orifice diameter on the safety and efficacy of LAAC using the LAmbre device. METHODS: A total of 133 patients with nonvalvular atrial fibrillation (AF) who underwent LAAC with the LAmbre device between June 2018 and June 2020 were included in this study. The patients were categorized into two groups based on the maximal diameter of the LAA orifice: the large LAA group (n = 45) with a maximal orifice diameter of ≥31 mm, and the normal LAA group (n = 88) with a maximal orifice diameter of <31 mm. The study assessed periprocedural characteristics and long-term clinical follow-up. RESULTS: Successful implantation of the LAmbre device was observed in all patients. The incidence of periprocedural peridevice leakage (PDL) was significantly higher in the large LAA group (P < 0.001), while the incidence of acute pericardial effusion (PE) during the procedure was comparable between the two groups (P = 1.000). After a mean follow-up period of 4.8 ± 1.7 years, three patients in the large LAA group developed delayed PE, while no patients in the normal LAA group did (P = 0.037). Additionally, a larger LAA maximal orifice diameter was associated with a higher prevalence of PDL (P = 0.001) and PE (including both acute and delayed PE) (P = 0.027). The optimal cutoff value of the LAA maximal orifice diameter for predicting PDL and PE after LAAC with the LAmbre device was determined to be 30 mm. CONCLUSION: The findings suggest that the LAmbre device is a safe and feasible option for occluding the LAA, regardless of its orifice diameter. However, it is important to note that a larger LAA orifice diameter may increase the risk of PDL and delayed PE.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Humanos , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Oclusão do Apêndice Atrial Esquerdo
16.
Circulation ; 145(21): 1592-1604, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35354306

RESUMO

BACKGROUND: In REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure), implantation of an atrial shunt device did not provide overall clinical benefit for patients with heart failure with preserved or mildly reduced ejection fraction. However, prespecified analyses identified differences in response in subgroups defined by pulmonary artery systolic pressure during submaximal exercise, right atrial volume, and sex. Shunt implantation reduces left atrial pressures but increases pulmonary blood flow, which may be poorly tolerated in patients with pulmonary vascular disease (PVD). On the basis of these results, we hypothesized that patients with latent PVD, defined as elevated pulmonary vascular resistance during exercise, might be harmed by shunt implantation, and conversely that patients without PVD might benefit. METHODS: REDUCE LAP-HF II enrolled 626 patients with heart failure, ejection fraction ≥40%, exercise pulmonary capillary wedge pressure ≥25 mm Hg, and resting pulmonary vascular resistance <3.5 Wood units who were randomized 1:1 to atrial shunt device or sham control. The primary outcome-a hierarchical composite of cardiovascular death, nonfatal ischemic stroke, recurrent HF events, and change in health status-was analyzed using the win ratio. Latent PVD was defined as pulmonary vascular resistance ≥1.74 Wood units (highest tertile) at peak exercise, measured before randomization. RESULTS: Compared with patients without PVD (n=382), those with latent PVD (n=188) were older, had more atrial fibrillation and right heart dysfunction, and were more likely to have elevated left atrial pressure at rest. Shunt treatment was associated with worse outcomes in patients with PVD (win ratio, 0.60 [95% CI, 0.42, 0.86]; P=0.005) and signal of clinical benefit in patients without PVD (win ratio, 1.31 [95% CI, 1.02, 1.68]; P=0.038). Patients with larger right atrial volumes and men had worse outcomes with the device and both groups were more likely to have pacemakers, heart failure with mildly reduced ejection fraction, and increased left atrial volume. For patients without latent PVD or pacemaker (n=313; 50% of randomized patients), shunt treatment resulted in more robust signal of clinical benefit (win ratio, 1.51 [95% CI, 1.14, 2.00]; P=0.004). CONCLUSIONS: In patients with heart failure with preserved or mildly reduced ejection fraction, the presence of latent PVD uncovered by invasive hemodynamic exercise testing identifies patients who may worsen with atrial shunt therapy, whereas those without latent PVD may benefit.


Assuntos
Cateterismo Cardíaco , Átrios do Coração , Insuficiência Cardíaca , Doenças Vasculares , Cateterismo Cardíaco/instrumentação , Feminino , Átrios do Coração/cirurgia , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Circulação Pulmonar , Volume Sistólico , Resultado do Tratamento , Doenças Vasculares/complicações
17.
Lancet ; 399(10330): 1130-1140, 2022 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-35120593

RESUMO

BACKGROUND: Placement of an interatrial shunt device reduces pulmonary capillary wedge pressure during exercise in patients with heart failure and preserved or mildly reduced ejection fraction. We aimed to investigate whether an interatrial shunt can reduce heart failure events or improve health status in these patients. METHODS: In this randomised, international, blinded, sham-controlled trial performed at 89 health-care centres, we included patients (aged ≥40 years) with symptomatic heart failure, an ejection fraction of at least 40%, and pulmonary capillary wedge pressure during exercise of at least 25 mm Hg while exceeding right atrial pressure by at least 5 mm Hg. Patients were randomly assigned (1:1) to receive either a shunt device or sham procedure. Patients and outcome assessors were masked to randomisation. The primary endpoint was a hierarchical composite of cardiovascular death or non-fatal ischemic stroke at 12 months, rate of total heart failure events up to 24 months, and change in Kansas City Cardiomyopathy Questionnaire overall summary score at 12 months. Pre-specified subgroup analyses were conducted for the heart failure event endpoint. Analysis of the primary endpoint, all other efficacy endpoints, and safety endpoints was conducted in the modified intention-to-treat population, defined as all patients randomly allocated to receive treatment, excluding those found to be ineligible after randomisation and therefore not treated. This study is registered with ClinicalTrials.gov, NCT03088033. FINDINGS: Between May 25, 2017, and July 24, 2020, 1072 participants were enrolled, of whom 626 were randomly assigned to either the atrial shunt device (n=314) or sham procedure (n=312). There were no differences between groups in the primary composite endpoint (win ratio 1·0 [95% CI 0·8-1·2]; p=0·85) or in the individual components of the primary endpoint. The prespecified subgroups demonstrating a differential effect of atrial shunt device treatment on heart failure events were pulmonary artery systolic pressure at 20W of exercise (pinteraction=0·002 [>70 mm Hg associated with worse outcomes]), right atrial volume index (pinteraction=0·012 [≥29·7 mL/m2, worse outcomes]), and sex (pinteraction=0·02 [men, worse outcomes]). There were no differences in the composite safety endpoint between the two groups (n=116 [38%] for shunt device vs n=97 [31%] for sham procedure; p=0·11). INTERPRETATION: Placement of an atrial shunt device did not reduce the total rate of heart failure events or improve health status in the overall population of patients with heart failure and ejection fraction of greater than or equal to 40%. FUNDING: Corvia Medical.


Assuntos
Cateterismo Cardíaco , Insuficiência Cardíaca , Adulto , Cateterismo Cardíaco/instrumentação , Flavinas , Átrios do Coração/cirurgia , Insuficiência Cardíaca/fisiopatologia , Humanos , Luciferases , Masculino , Volume Sistólico
18.
J Interv Cardiol ; 2022: 5488654, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35281587

RESUMO

Background: Implantation of the MitraClip is a safe and effective therapy for mitral valve repair in patients ineligible for surgery or at high risk of adverse surgical outcomes. However, only limited information is available concerning sex differences in transcatheter mitral valve repair. We therefore sought to conduct a comprehensive meta-analysis of studies that investigated differences between men and women in outcomes following MitraClip implantation. Methods: The PubMed and Embase databases were searched until November 2019 for studies reporting outcomes after MitraClip implantation in women versus men. Outcomes included all-cause mortality and major complications at 30 days and one year of follow-up. Results: Six studies (n = 1,109 women; n = 1,743 men) were analyzed. At 30 days, women had a similar risk of postoperative complications, such as stroke, major bleeding, and pericardium effusion, without differences in all-cause mortality, procedure success, or MitraClip usage. At one year, the all-cause mortality, the reduction of mitral regurgitation, and the risk of rehospitalization for heart failure were also comparable between male and female patients. Conclusion: Gender disparity was not found in complications or prognosis of patients undergoing MitraClip implantation. This study suggests that gender should not be considered as a critical factor in the selection of patients as candidates for MitraClip implantation of concern during follow-up.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Fatores Sexuais , Resultado do Tratamento
19.
Circulation ; 142(24): 2371-2388, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33315494

RESUMO

Ischemic strokes related to atrial fibrillation are highly prevalent, presenting with severe neurologic syndromes and associated with high risk of recurrence. Although advances have been made in both primary and secondary stroke prevention for patients with atrial fibrillation, the long-term risks for stroke recurrence and bleeding complications from antithrombotic treatment remain substantial. We summarize the major advances in stroke prevention for patients with atrial fibrillation during the past 30 years and focus on novel diagnostic and treatment approaches currently under investigation in ongoing clinical trials. Non-vitamin K antagonist oral anticoagulants have been proven to be safer and equally effective compared with warfarin in stroke prevention for patients with nonvalvular atrial fibrillation. Non-vitamin K antagonist oral anticoagulants are being investigated for the treatment of patients with atrial fibrillation and rheumatic heart disease, for the treatment of patients with recent embolic stroke of undetermined source and indirect evidence of cardiac embolism, and in the prevention of vascular-mediated cognitive decline in patients with atrial fibrillation. Multiple clinical trials are assessing the optimal timing of non-vitamin K antagonist oral anticoagulant initiation after a recent ischemic stroke and the benefit:harm ratio of non-vitamin K antagonist oral anticoagulant treatment in patients with atrial fibrillation and history of previous intracranial bleeding. Ongoing trials are addressing the usefulness of left atrial appendage occlusion in both primary and secondary stroke prevention for patients with atrial fibrillation, including those with high risk of bleeding. The additive value of prolonged cardiac monitoring for subclinical atrial fibrillation detection through smartphone applications or implantable cardiac devices, together with the optimal medical management of individuals with covert paroxysmal atrial fibrillation, is a topic of intensive research interest. Colchicine treatment and factor XIa inhibition constitute 2 novel pharmacologic approaches that might provide future treatment options in the secondary prevention of cardioembolic stroke attributable to atrial fibrillation.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco , AVC Isquêmico/prevenção & controle , Administração Oral , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Difusão de Inovações , Esquema de Medicação , Eletrocardiografia , Feminino , Humanos , AVC Isquêmico/diagnóstico , AVC Isquêmico/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
20.
J Interv Cardiol ; 2021: 1905184, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33628143

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the feasibility and safety of myocardial biopsy using a new approach, the Liwen procedure. BACKGROUND: Myocardial biopsy is essential when other methods could not differentiate other etiologies from hypertrophic obstructive cardiomyopathy (HOCM). Our previous work using intramyocardial radiofrequency ablation for hypertrophic obstructive cardiomyopathy (Liwen procedure) may provide another approach to obtain the myocardial samples. METHOD: Seventeen patients with HOCM were enrolled for biopsies through percutaneously accessed intramyocardial septum and evaluated possible complications. RESULTS: We obtained 31 specimens from 17 patients with a success rate of sample acquisition 100.0%. The number of myocardial samples taken per patient was 1.8 ± 0.8, and the average length of all samples was 16.7 ± 5.6 mm which could be used for pathological diagnosis. The complications included pericardial effusion with and without tamponade in one patient (5.9%), and no incidence of nonsustained and sustained ventricular tachycardia, conduction abnormity, perforation, stroke, and pneumothorax. The inhospital and 30-day mortality was 0%. CONCLUSION: This study has shown that myocardial biopsy of the Liwen procedure is relatively safe and technically feasible with adequate tissue sampling, which may help pathological diagnosis and further research of HOCM of diverse etiologies. This trial is registered with NCT04355260.


Assuntos
Biópsia , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica/diagnóstico , Miocárdio/patologia , Derrame Pericárdico , Complicações Pós-Operatórias/diagnóstico , Biópsia/efeitos adversos , Biópsia/métodos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Cardiomiopatia Hipertrófica/etiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA