Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29.548
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Nature ; 626(8001): 990-998, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38383782

RESUMO

Electrode-based electrical stimulation underpins several clinical bioelectronic devices, including deep-brain stimulators1,2 and cardiac pacemakers3. However, leadless multisite stimulation is constrained by the technical difficulties and spatial-access limitations of electrode arrays. Optogenetics offers optically controlled random access with high spatiotemporal capabilities, but clinical translation poses challenges4-6. Here we show tunable spatiotemporal photostimulation of cardiac systems using a non-genetic platform based on semiconductor-enabled biomodulation interfaces. Through spatiotemporal profiling of photoelectrochemical currents, we assess the magnitude, precision, accuracy and resolution of photostimulation in four leadless silicon-based monolithic photoelectrochemical devices. We demonstrate the optoelectronic capabilities of the devices through optical overdrive pacing of cultured cardiomyocytes (CMs) targeting several regions and spatial extents, isolated rat hearts in a Langendorff apparatus, in vivo rat hearts in an ischaemia model and an in vivo mouse heart model with transthoracic optical pacing. We also perform the first, to our knowledge, optical override pacing and multisite pacing of a pig heart in vivo. Our systems are readily adaptable for minimally invasive clinical procedures using our custom endoscopic delivery device, with which we demonstrate closed-thoracic operations and endoscopic optical stimulation. Our results indicate the clinical potential of the leadless, lightweight and multisite photostimulation platform as a pacemaker in cardiac resynchronization therapy (CRT), in which lead-placement complications are common.


Assuntos
Terapia de Ressincronização Cardíaca , Desenho de Equipamento , Marca-Passo Artificial , Silício , Animais , Camundongos , Ratos , Terapia de Ressincronização Cardíaca/métodos , Endoscopia , Coração , Procedimentos Cirúrgicos Minimamente Invasivos , Isquemia Miocárdica/cirurgia , Isquemia Miocárdica/terapia , Miócitos Cardíacos , Semicondutores , Suínos , Modelos Animais
2.
Nature ; 615(7951): 292-299, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36859543

RESUMO

Emotional states influence bodily physiology, as exemplified in the top-down process by which anxiety causes faster beating of the heart1-3. However, whether an increased heart rate might itself induce anxiety or fear responses is unclear3-8. Physiological theories of emotion, proposed over a century ago, have considered that in general, there could be an important and even dominant flow of information from the body to the brain9. Here, to formally test this idea, we developed a noninvasive optogenetic pacemaker for precise, cell-type-specific control of cardiac rhythms of up to 900 beats per minute in freely moving mice, enabled by a wearable micro-LED harness and the systemic viral delivery of a potent pump-like channelrhodopsin. We found that optically evoked tachycardia potently enhanced anxiety-like behaviour, but crucially only in risky contexts, indicating that both central (brain) and peripheral (body) processes may be involved in the development of emotional states. To identify potential mechanisms, we used whole-brain activity screening and electrophysiology to find brain regions that were activated by imposed cardiac rhythms. We identified the posterior insular cortex as a potential mediator of bottom-up cardiac interoceptive processing, and found that optogenetic inhibition of this brain region attenuated the anxiety-like behaviour that was induced by optical cardiac pacing. Together, these findings reveal that cells of both the body and the brain must be considered together to understand the origins of emotional or affective states. More broadly, our results define a generalizable approach for noninvasive, temporally precise functional investigations of joint organism-wide interactions among targeted cells during behaviour.


Assuntos
Comportamento Animal , Encéfalo , Emoções , Coração , Animais , Camundongos , Ansiedade/fisiopatologia , Encéfalo/fisiologia , Mapeamento Encefálico , Emoções/fisiologia , Coração/fisiologia , Comportamento Animal/fisiologia , Eletrofisiologia , Optogenética , Córtex Insular/fisiologia , Frequência Cardíaca , Channelrhodopsins , Taquicardia/fisiopatologia , Marca-Passo Artificial
3.
N Engl J Med ; 391(15): 1402-1412, 2024 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-38767244

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).


Assuntos
Arritmias Cardíacas , Bradicardia , Morte Súbita Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Bradicardia/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Desenho de Equipamento , Seguimentos , Marca-Passo Artificial/efeitos adversos , Tecnologia sem Fio , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia
4.
Annu Rev Med ; 75: 475-492, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37989145

RESUMO

Cardiac pacing to treat bradyarrhythmias has evolved in recent decades. Recognition that a substantial proportion of pacemaker-dependent patients can develop heart failure due to electrical and mechanical dyssynchrony from traditional right ventricular apical pacing has led to development of more physiologic pacing methods that better mimic normal cardiac conduction and provide synchronized ventricular contraction. Conventional biventricular pacing has been shown to benefit patients with heart failure and conduction system disease but can be limited by scarring and fibrosis. His bundle pacing and left bundle branch area pacing are novel techniques that can provide more physiologic ventricular activation as an alternative to conventional or biventricular pacing. Leadless pacing has emerged as another alternative pacing technique to overcome limitations in conventional transvenous pacemaker systems. Our objective is to review the evolution of cardiac pacing and explore these new advances in pacing strategies.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração , Insuficiência Cardíaca/terapia , Resultado do Tratamento
5.
N Engl J Med ; 388(25): 2360-2370, 2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37212442

RESUMO

BACKGROUND: Single-chamber ventricular leadless pacemakers do not support atrial pacing or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system consisting of two devices implanted percutaneously, one in the right atrium and one in the right ventricle, would make leadless pacemaker therapy a treatment option for a wider range of indications. METHODS: We conducted a prospective, multicenter, single-group study to evaluate the safety and performance of a dual-chamber leadless pacemaker system. Patients with a conventional indication for dual-chamber pacing were eligible for participation. The primary safety end point was freedom from complications (i.e., device- or procedure-related serious adverse events) at 90 days. The first primary performance end point was a combination of adequate atrial capture threshold and sensing amplitude at 3 months. The second primary performance end point was at least 70% atrioventricular synchrony at 3 months while the patient was sitting. RESULTS: Among the 300 patients enrolled, 190 (63.3%) had sinus-node dysfunction and 100 (33.3%) had atrioventricular block as the primary pacing indication. The implantation procedure was successful (i.e., two functioning leadless pacemakers were implanted and had established implant-to-implant communication) in 295 patients (98.3%). A total of 35 device- or procedure-related serious adverse events occurred in 29 patients. The primary safety end point was met in 271 patients (90.3%; 95% confidence interval [CI], 87.0 to 93.7), which exceeded the performance goal of 78% (P<0.001). The first primary performance end point was met in 90.2% of the patients (95% CI, 86.8 to 93.6), which exceeded the performance goal of 82.5% (P<0.001). The mean (±SD) atrial capture threshold was 0.82±0.70 V, and the mean P-wave amplitude was 3.58±1.88 mV. Of the 21 patients (7%) with a P-wave amplitude of less than 1.0 mV, none required device revision for inadequate sensing. At least 70% atrioventricular synchrony was achieved in 97.3% of the patients (95% CI, 95.4 to 99.3), which exceeded the performance goal of 83% (P<0.001). CONCLUSIONS: The dual-chamber leadless pacemaker system met the primary safety end point and provided atrial pacing and reliable atrioventricular synchrony for 3 months after implantation. (Funded by Abbott Medical; Aveir DR i2i ClinicalTrials.gov number, NCT05252702.).


Assuntos
Arritmias Cardíacas , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Fibrilação Atrial/terapia , Fibrilação Atrial/etiologia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Seguimentos , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Arritmias Cardíacas/terapia
6.
Circulation ; 150(6): 439-450, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-38973458

RESUMO

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of atrioventricular synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between atrioventricular synchrony and i2i success, posture/activity, implantation indication, atrioventricular event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean atrioventricular synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrial-to-ventricular i2i (94%) and ventricular-to-atrial i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. Atrioventricular synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, atrioventricular paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated atrioventricular synchrony in 98% of evaluable beats at 3 months after implantation. Atrioventricular synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.


Assuntos
Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Idoso de 80 Anos ou mais , Frequência Cardíaca , Eletrocardiografia Ambulatorial , Pessoa de Meia-Idade , Estimulação Cardíaca Artificial/métodos
7.
Circulation ; 150(8): e183-e196, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-38984417

RESUMO

The rapid technological advancements in cardiac implantable electronic devices such as pacemakers, implantable cardioverter defibrillators, and loop recorders, coupled with a rise in the number of patients with these devices, necessitate an updated clinical framework for periprocedural management. The introduction of leadless pacemakers, subcutaneous and extravascular defibrillators, and novel device communication protocols underscores the imperative for clinical updates. This scientific statement provides an inclusive framework for the periprocedural management of patients with these devices, encompassing the planning phase, procedure, and subsequent care coordinated with the primary device managing clinic. Expert contributions from anesthesiologists, cardiac electrophysiologists, and cardiac nurses are consolidated to appraise current evidence, offer patient and health system management strategies, and highlight key areas for future research. The statement, pertinent to a wide range of health care professionals, underscores the importance of quality care pathways for patient safety, optimal device function, and minimization of hemodynamic disturbances or arrhythmias during procedures. Our primary objective is to deliver quality care to the expanding patient cohort with cardiac implanted electronic devices, offering direction in the era of evolving technologies and laying a foundation for sustained education and practice enhancement.


Assuntos
American Heart Association , Desfibriladores Implantáveis , Marca-Passo Artificial , Assistência Perioperatória , Humanos , Desfibriladores Implantáveis/normas , Estados Unidos , Assistência Perioperatória/normas , Assistência Perioperatória/métodos , Equipe de Assistência ao Paciente , Arritmias Cardíacas/terapia
8.
Circulation ; 150(5): 350-361, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38940005

RESUMO

BACKGROUND: Current estimates of atrial fibrillation (AF)-associated mortality rely on claims- or clinical-derived diagnoses of AF, limit AF to a binary entity, or are confounded by comorbidities. The objective of the present study is to assess the association between device-recognized AF and mortality among patients with cardiac implantable electronic devices capable of sensitive and continuous atrial arrhythmia detection. Secondary outcomes include relative mortality among cohorts with no AF, paroxysmal AF, persistent AF, and permanent AF. METHODS: Using the deidentified Optum Clinformatics US claims database (2015 to 2020) linked to the Medtronic CareLink database, we identified individuals with a cardiac implantable electronic device who transmitted data ≥6 months after implantation. AF burden was assessed during the first 6 months after implantation (baseline period). Subsequent mortality, assessed from claims data, was compared between patients with and without AF, with adjustment for age, geographic region, insurance type, Charlson Comorbidity Index, and implantation year. RESULTS: Of 21 391 patients (age, 72.9±10.9 years; 56.3% male) analyzed, 7798 (36.5%) had device-recognized AF. During a mean of 22.4±12.9 months (median, 20.1 [12.8-29.7] months) of follow-up, the overall incidence of mortality was 13.5%. Patients with AF had higher adjusted all-cause mortality than patients without AF (hazard ratio, 1.29 [95% CI, 1.20-1.39]; P<0.001). Among those with AF, patients with nonparoxysmal AF had the greatest risk of mortality (persistent AF versus paroxysmal AF: hazard ratio, 1.36 [95% CI, 1.18-1.58]; P<.001; permanent AF versus paroxysmal AF: hazard ratio, 1.23 [95% CI, 1.14-1.34]; P<.001). CONCLUSIONS: After adjustment for potential confounding factors, the presence of AF was associated with higher mortality in our cohort of patients with cardiac implantable electronic devices. Among those with AF, nonparoxysmal AF was associated with the greatest risk of mortality.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Humanos , Fibrilação Atrial/mortalidade , Fibrilação Atrial/diagnóstico , Idoso , Masculino , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Marca-Passo Artificial , Fatores de Risco , Bases de Dados Factuais , Estados Unidos/epidemiologia
9.
Circulation ; 150(15): 1161-1170, 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39101218

RESUMO

BACKGROUND: Bradycardia is more common among well-trained athletes than in the general population, but the association with pacemaker implantations is less known. We investigated associations of endurance training with incidence of bradycardia and pacemaker implantations, including sex differences and long-term outcome, in a cohort of endurance trained individuals. METHODS: All Swedish skiers who completed >1 race in the cross-country skiing event Vasaloppet between 1989 and 2011 (n=209 108) and a sample of 532 290 nonskiers were followed until first event of bradycardia, pacemaker implantation, or death, depending on end point. The Swedish National Patient Register was used to obtain diagnoses. Cox regression was used to investigate associations of number of completed races and finishing time in Vasaloppet with incidence of bradycardia and pacemaker implantations. In addition, Cox regression was used to investigate associations of pacemaker implantations with death in skiers and nonskiers. RESULTS: Male skiers had a higher incidence of bradycardia (adjusted hazard ratio [aHR], 1.19 [95% CI, 1.05-1.34]) and pacemaker implantations (aHR, 1.17 [95% CI, 1.04-1.31]) compared with male nonskiers. Those who completed the most races and had the best performances exhibited the highest incidence. For female skiers in Vasaloppet, the incidence of bradycardia (aHR, 0.98 [95% CI, 0.75-1.30]) and pacemaker implantations (aHR, 0.98 [95% CI, 0.75-1.29]) was not different from that of female nonskiers. The indication for pacemaker differed between skiers and nonskiers, with sick sinus syndrome more common in the former and third-degree atrioventricular block in the latter. Skiers had lower overall mortality rates than nonskiers (aHR, 0.16 [95% CI, 0.15-0.17]). There were no differences in mortality rates by pacemaker status among skiers. CONCLUSIONS: In this study, male endurance skiers had a higher incidence of bradycardia and pacemaker implantations compared with nonskiers, a pattern not seen in women. Among male skiers, those who completed the most races and had the fastest finishing times had the highest incidence of bradycardia and pacemaker implantations. Within each group, mortality rates did not differ in relation to pacemaker status. These findings suggest that bradycardia associated with training leads to a higher risk for pacemaker implantation without a detrimental effect on mortality risk.


Assuntos
Bradicardia , Marca-Passo Artificial , Esqui , Humanos , Bradicardia/epidemiologia , Bradicardia/mortalidade , Bradicardia/terapia , Masculino , Feminino , Incidência , Suécia/epidemiologia , Adulto , Estudos de Coortes , Pessoa de Meia-Idade , Resistência Física , Fatores Sexuais , Adulto Jovem , Sistema de Registros
10.
N Engl J Med ; 386(4): 327-339, 2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-34767705

RESUMO

BACKGROUND: Tricuspid regurgitation is common in patients with severe degenerative mitral regurgitation. However, the evidence base is insufficient to inform a decision about whether to perform tricuspid-valve repair during mitral-valve surgery in patients who have moderate tricuspid regurgitation or less-than-moderate regurgitation with annular dilatation. METHODS: We randomly assigned 401 patients who were undergoing mitral-valve surgery for degenerative mitral regurgitation to receive a procedure with or without tricuspid annuloplasty (TA). The primary 2-year end point was a composite of reoperation for tricuspid regurgitation, progression of tricuspid regurgitation by two grades from baseline or the presence of severe tricuspid regurgitation, or death. RESULTS: Patients who underwent mitral-valve surgery plus TA had fewer primary-end-point events than those who underwent mitral-valve surgery alone (3.9% vs. 10.2%) (relative risk, 0.37; 95% confidence interval [CI], 0.16 to 0.86; P = 0.02). Two-year mortality was 3.2% in the surgery-plus-TA group and 4.5% in the surgery-alone group (relative risk, 0.69; 95% CI, 0.25 to 1.88). The 2-year prevalence of progression of tricuspid regurgitation was lower in the surgery-plus-TA group than in the surgery-alone group (0.6% vs. 6.1%; relative risk, 0.09; 95% CI, 0.01 to 0.69). The frequencies of major adverse cardiac and cerebrovascular events, functional status, and quality of life were similar in the two groups at 2 years, although the incidence of permanent pacemaker implantation was higher in the surgery-plus-TA group than in the surgery-alone group (14.1% vs. 2.5%; rate ratio, 5.75; 95% CI, 2.27 to 14.60). CONCLUSIONS: Among patients undergoing mitral-valve surgery, those who also received TA had a lower incidence of a primary-end-point event than those who underwent mitral-valve surgery alone at 2 years, a reduction that was driven by less frequent progression to severe tricuspid regurgitation. Tricuspid repair resulted in more frequent permanent pacemaker implantation. Whether reduced progression of tricuspid regurgitation results in long-term clinical benefit can be determined only with longer follow-up. (Funded by the National Heart, Lung, and Blood Institute and the German Center for Cardiovascular Research; ClinicalTrials.gov number, NCT02675244.).


Assuntos
Anuloplastia da Valva Cardíaca , Progressão da Doença , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Dilatação Patológica , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/mortalidade , Marca-Passo Artificial , Complicações Pós-Operatórias , Qualidade de Vida , Reoperação , Análise de Sobrevida , Valva Tricúspide/patologia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/terapia
11.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38426911

RESUMO

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Sistema de Registros , Estimulação Cardíaca Artificial/efeitos adversos
12.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38096587

RESUMO

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Cardiopatia Reumática , Insuficiência da Valva Tricúspide , Humanos , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Cardiopatia Reumática/complicações , Estudos Retrospectivos
13.
Eur Heart J ; 45(31): 2878-2890, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38953772

RESUMO

BACKGROUND AND AIMS: Incidence and types of secondary tricuspid regurgitation (TR) are not well defined in atrial fibrillation (AFib) and sinus rhythm (SR). Atrial secondary TR (A-STR) is associated with pre-existing AFib; however, close to 50% of patients with A-STR do not have AFib. The aim of this study was to assess incidence, types, and outcomes of ≥ moderate TR in AFib vs. SR. METHODS: Adults with and without new-onset AFib without structural heart disease or ≥ moderate TR at baseline were followed for the development of ≥ moderate TR. Tricuspid regurgitation types were pacemaker, left-sided valve disease, left ventricular (LV) dysfunction, pulmonary hypertension (PH), isolated ventricular, and A-STR. RESULTS: Among 1359 patients with AFib and 20 438 in SR, 109 and 378 patients developed ≥ moderate TR, respectively. The individual types of TR occurred more frequently in AFib related to the higher pacemaker implantation rates (1.12 vs. 0.19 per 100 person-years, P < .001), larger right atrial size (median 78 vs. 53 mL, P < .001), and higher pulmonary pressures (median 30 vs. 28 mmHg, P < .001). The most common TR types irrespective of rhythm were LV dysfunction-TR and A-STR. Among patients in SR, those with A-STR were older, predominantly women with more diastolic abnormalities and higher pulmonary pressures. All types of secondary TR were associated with all-cause mortality, highest in PH-TR and LV dysfunction-TR. CONCLUSIONS: New-onset AFib vs. SR conferred a higher risk of the individual TR types related to sequelae of AFib and higher pacemaker implantation rates, although the distribution of TR types was similar. Secondary TR was universally associated with increased mortality.


Assuntos
Fibrilação Atrial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/fisiopatologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Feminino , Masculino , Idoso , Incidência , Pessoa de Meia-Idade , Marca-Passo Artificial
14.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
15.
Clin Infect Dis ; 79(3): 663-671, 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-38913722

RESUMO

BACKGROUND: Information on infective endocarditis (IE) caused by Cutibacterium spp. is limited and new Duke-International Society for Cardiovascular Infectious Diseases (ISCVID) criteria have not yet been properly assessed. We examined clinical characteristics, outcomes, and performance of diagnostic tests for Cutibacterium valvular and cardiac implantable electronic device-related IE (CIED-IE). METHODS: Data corresponding to all episodes of Cutibacterium IE recorded from 2008 to 2023 in a prospective national cohort including 46 Spanish hospitals were examined. Possible IE cases were reassessed using the new criteria. The sensitivity of blood cultures, valvular and CIED cultures, and polymerase chain reaction of the 16S rRNA gene and sequencing (16SPCR) was evaluated. RESULTS: Of 6692 episodes of IE, 67 (1%) were caused by Cutibacterium spp. with 85% affecting men. Of these, 50 were valve-related (45 prosthetic, 5 native) and 17 CIED-related. The new criteria identified 8 additional cases and reclassified 15 as definite IE. Intracardiac complications (abscess, pseudoaneurysm, perforation, or intracardiac fistula) occurred in 23 of 50 (46%) valvular IE episodes, leading to 18% mortality, and up to 40% mortality if surgery was indicated but could not be performed. All CIED-IE cases underwent device removal and no deaths were recorded. Positive diagnosis rates for blood cultures, valve/device cultures, and 16SPCR were 52%, 70%, and 82%, respectively. CONCLUSIONS: Cutibacterium IE is a rare yet potentially life-threatening condition that warrants a high index of suspicion in men with endovascular prosthetic material. The new Duke-ISCVID criteria and molecular techniques are useful for its diagnosis. Considering a significant complication rate, cardiac surgery and removal of CIEDs play a key role in reducing mortality.


Assuntos
Endocardite Bacteriana , Infecções Relacionadas à Prótese , Humanos , Masculino , Feminino , Estudos Prospectivos , Idoso , Pessoa de Meia-Idade , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/diagnóstico , RNA Ribossômico 16S/genética , Propionibacteriaceae/isolamento & purificação , Propionibacteriaceae/genética , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/microbiologia , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/microbiologia , Idoso de 80 Anos ou mais , Espanha/epidemiologia , Adulto , Desfibriladores Implantáveis/efeitos adversos
16.
Am J Physiol Heart Circ Physiol ; 327(5): H1146-H1152, 2024 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-39240255

RESUMO

Mitochondrial dysfunction contributes significantly to the development of atrial fibrillation (AF). Conflicting data regarding the atrial pacing and the risk of AF existed, and the impact of atrial pacing on mitochondrial function remains unknown. Therefore, we sought to examine the association between atrial pacing percentage and mitochondrial function in patients with cardiovascular implantable electronic devices (CIEDs) with atrial pacing capability. This is a cross-sectional study involving 183 patients with CIEDs with atrial pacing capability. The oxidative stress and mitochondrial function were determined in peripheral blood mononuclear cells (PBMCs). Among 183 patients, 55.7% had permanent pacemakers, 7.7% had defibrillators, and 36.6% had cardiac resynchronization therapy. Mean age was 67.5 ± 14.7 yr with 51% being male. Mean left ventricular ejection fraction (LVEF) was 53.9 ± 16.8%. We demonstrated that the presence of atrial pacing above 50% correlated with higher levels of mitochondrial spared respiratory capacity (P = 0.043) and coupling efficiency (P = 0.045). After adjusting with multiple linear regression for age, sex, LVEF, history of AF, sick sinus syndrome, comorbidities, estimated glomerular filtration rate (eGFR), cardiac resynchronization therapy (CRT), and percentage of ventricular pacing, our findings revealed a statistically significant association between a higher percentage of atrial pacing and increased spared respiratory capacity (ß, 0.217, P = 0.046), lower nonmitochondrial respiration (ß, -0.230; P = 0.023), and proton leak (ß, -0.247; P = 0.022). We demonstrated that atrial pacing enhances mitochondrial performance in PBMCs and left ventricular contractile performance in patients with CIEDs. This observation may serve as an additional support for the preventive effect of atrial pacing in the prevention of atrial arrhythmia.NEW & NOTEWORTHY Atrial pacing enhances mitochondrial spare respiratory capacity and reduces proton leak. This finding may provide further evidence supporting the preventive role of atrial pacing in reducing the risk of atrial fibrillation in patients with cardiac implantable electronic devices.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Leucócitos Mononucleares , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estudos Transversais , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Leucócitos Mononucleares/metabolismo , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Estresse Oxidativo , Estimulação Cardíaca Artificial , Mitocôndrias Cardíacas/metabolismo , Função Ventricular Esquerda , Terapia de Ressincronização Cardíaca , Átrios do Coração/fisiopatologia , Mitocôndrias/metabolismo
17.
Magn Reson Med ; 92(5): 2237-2245, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38968006

RESUMO

The "5 gauss line" is a phrase that is likely to be familiar to everyone working with MRI, but what is its significance, how was it defined, and what changes are currently in progress? This review explores the history of 5 gauss (0.5 mT) as a threshold for protecting against inadvertently putting cardiac pacemakers, implantable cardioverter defibrillators, and other active implantable medical devices into a "magnet mode." Additionally, it describes the background to the recent change of this threshold to 9 gauss (0.9 mT) in the International Standard IEC 60601-2-33 edition 4.0 that defines basic safety requirements for MRI. Practical implications of this change and some ongoing and emerging issues are also discussed.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Marca-Passo Artificial , Desfibriladores Implantáveis , Próteses e Implantes , Segurança de Equipamentos , Imãs , Campos Eletromagnéticos
18.
J Cardiovasc Electrophysiol ; 35(3): 433-437, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38205869

RESUMO

BACKGROUND: Pneumothorax is a well-recognized complication of cardiac implantable electronic device (CIED) insertion. While AP fluoroscopy alone is the most commonly imaging technique for subclavian or axillary access, caudal fluoroscopy (angle 40°) is routinely used at our institution. The caudal view provides additional separation of the first rib and clavicle and may reduce the risk of pneumothorax. We assessed outcomes at our institution of AP and caudal fluoroscopic guided pacing lead insertion. METHODS: Retrospective cohort study of consecutive patients undergoing transvenous lead insertion for pacemakers, defibrillators, and cardiac resynchronization therapy devices between 2011 and 2023. Both de novo and lead replacement/upgrade procedures were included. Data were extracted from operative, radiology, and discharge reports. All patients underwent postprocedure chest radiography. RESULTS: Three thousand two hundred fifty-two patients underwent insertion of pacing leads between February 2011 and March 2023. Mean age was 71.1 years (range 16-102) and 66.7% were male. Most (n = 2536; 78.0%) procedures used caudal guidance to obtain venous access, while 716 (22.0%) procedures used AP guidance alone. Pneumothoraxes occurred in five (0.2%) patients in the caudal group and five (0.7%) patients in the AP group (p = .03). Subclavian contrast venography was performed less frequently in the caudal group (26.2% vs. 42.7%, p < .01). CONCLUSION: Caudal fluoroscopy for axillary/subclavian access is associated with a lower rate of pneumothorax and contrast venography compared with an AP approach.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Pneumotórax , Humanos , Masculino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Veia Axilar , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Fluoroscopia/métodos , Desfibriladores Implantáveis/efeitos adversos
19.
J Cardiovasc Electrophysiol ; 35(3): 418-421, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38213071

RESUMO

INTRODUCTION: Patients with congenital heart disease are at increased risk for requiring cardiac pacing during their lifetime. METHODS: We present the first described case of using two leadless pacing systems manufactured by separate companies implanted within the same patient to provide atrial and ventricular pacing due to complex congenital anatomy. RESULTS: A 27-year-old male with dextrocardia with double outlet right ventricle, subaortic ventricular septal defect, and pulmonary stenosis status-post pulmonary valve replacement complicated by ventricular pacing dependence and subsequent atrial pacing dependence after atriotomy-based atypical flutter ablation developed recurrent mediastinitis and pocket infection with erosion despite prolonged antibiotic treatment. Due to atrial and ventricular pacing dependence, a comprehensive congenital care team concluded the need for lead extraction and replacement of pacemaker via leadless peacemaking device. Laser-lead extraction and temporary atrial pacemaker placement was performed. Afterward, a transesophageal echocardiogram guided implantation of both a Micra AV 2 (Medtronic) leadless pacemaker in the interventricular septum within the right ventricle and an Aveir (Abbott) leadless pacemaker in the superior base of the right atrial appendage was performed with successful pacing. Although there is no communication between these devices, atrial-mechanical ventricular pacing was reliable with good implant thresholds, impedances and sensing from both devices. CONCLUSION: Our case demonstrates the feasibility of using dual leadless pacing modalities to simultaneously pace someone at complex, prohibitive risk for temporary permanent or permanent pacemaker devices.


Assuntos
Dextrocardia , Dupla Via de Saída do Ventrículo Direito , Marca-Passo Artificial , Masculino , Humanos , Adulto , Estimulação Cardíaca Artificial/efeitos adversos , Ventrículos do Coração , Dupla Via de Saída do Ventrículo Direito/etiologia , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Desenho de Equipamento
20.
J Cardiovasc Electrophysiol ; 35(4): 747-761, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38361241

RESUMO

INTRODUCTION: The implantation of a cardiac implantable electronic device (CIED) can have esthetic and psychological consequences on patients. We explore a heart team model for care coordination and discuss esthetic approaches for improved cosmetic outcomes in patients undergoing (CIED)-related procedures or de novo implantation. METHODS: Patients undergoing CIED surgery for approved indications between June 2015 and June 2022 were identified. Patients were included when surgical care was provided by a collaborative relationship between the primary electrophysiologist and the plastic surgeon. Patient demographics, details of the surgical procedure, information on breast implants, complications, and outcomes related to cosmesis were recorded. RESULTS: Twenty-two female patients were included in this study. The mean age was 50.2 ± 18.2 years. The mean follow-up duration was 2.2 ± 5.5 months. The top two indications for the procedure included CIED generator change (n = 9, 41%) and implantable cardioverter-defibrillator (ICD) implantation (n = 7, 32%). The most common reasons for involving plastic surgery in the procedure included surgery near breast implants (n = 10, 45%) and device displacement or discomfort (n = 8, 36%). CIED pocket position was prepectoral in 10 cases (45%), subpectoral in 11 patients (50%), and intramuscular in one patient (4.5%). The majority of the patients (20, 91%) had cosmetically acceptable results postprocedure. One patient (4.5%) had breast asymmetry on the CIED side, and another continued to have skin erosion over the CIED and leads. CONCLUSION: A heart team approach incorporating the expertize of cardiac electrophysiology and plastic surgery is essential for providing optimal care for patients with breast implants and patients requesting esthetic appeal.


Assuntos
Implantes de Mama , Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Implantes de Mama/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA