Eur Respir J ; 63(6)2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38548291

RESUMO

BACKGROUND: Differences in the pharyngeal site of collapse influence efficacy of non-continuous positive airway pressure therapies for obstructive sleep apnoea (OSA). Notably, complete concentric collapse at the level of the palate (CCCp) during drug-induced sleep endoscopy (DISE) is associated with reduced efficacy of hypoglossal nerve stimulation, but CCCp is currently not recognisable using polysomnography. Here we develop a means to estimate DISE-based site of collapse using overnight polysomnography. METHODS: 182 OSA patients provided DISE and polysomnography data. Six polysomnographic flow shape characteristics (mean during hypopnoeas) were identified as candidate predictors of CCCp (primary outcome variable, n=44/182), including inspiratory skewness and inspiratory scoopiness. Multivariable logistic regression combined the six characteristics to predict clear presence (n=22) versus absence (n=128) of CCCp (partial collapse and concurrent tongue base collapse excluded). Odds ratios for actual CCCp between predicted subgroups were quantified after cross-validation. Secondary analyses examined complete lateral wall, tongue base or epiglottis collapse. External validation was performed on a separate dataset (ntotal=466). RESULTS: CCCp was characterised by greater scoopiness (ß=1.5±0.6 per 2sd, multivariable estimate±se) and skewness (ß=11.4±2.4) compared with non-CCCp. The odds ratio for CCCp in predicted positive versus negative subgroups was 5.0 (95% CI 1.9-13.1). The same characteristics provided significant cross-validated prediction of lateral wall (OR 6.3, 95% CI 2.4-16.5), tongue base (OR 3.2, 95% CI 1.4-7.3) and epiglottis (OR 4.4, 95% CI 1.5-12.4) collapse. CCCp and lateral wall collapse shared similar characteristics (skewed, scoopy), diametrically opposed to tongue base and epiglottis collapse characteristics. External validation confirmed model prediction. CONCLUSIONS: The current study provides a means to recognise patients with likely CCCp or other DISE-based site of collapse categories using routine polysomnography. Since site of collapse influences therapeutic responses, polysomnographic airflow shape analysis could facilitate precision site-specific OSA interventions.


Assuntos
Endoscopia , Polissonografia , Apneia Obstrutiva do Sono , Humanos , Masculino , Feminino , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Pessoa de Meia-Idade , Adulto , Modelos Logísticos , Sono , Idoso , Língua/fisiopatologia , Faringe/fisiopatologia , Nervo Hipoglosso , Análise Multivariada , Palato , Epiglote/fisiopatologia , Pressão Positiva Contínua nas Vias Aéreas
2.
Sleep Breath ; 28(1): 221-230, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37542679

RESUMO

BACKGROUND: Breathing-synchronized hypoglossal nerve stimulation (HNS) is routinely used as an alternative treatment for patients with obstructive sleep apnea (OSA). Significant and clinically relevant improvements in disease severity and OSA symptoms such as daytime sleepiness as well as overall quality of life have been reported in randomized-controlled trials and large real-world cohort studies. However, so far, few data exist on patient-reported experience with the treatment. METHODS: A structured survey with 22 questions was constructed using five-level Likert scales (1 = no agreement, 5 = complete agreement) to evaluate patient experience with HNS and perception of the treatment in the domains "Overall experience with therapy," "Experience with treatment process," and "Side-effects from treatment." Additional data were collected on current symptom status, measured with Epworth sleepiness scale (ESS) questionnaire, and OSA disease history. Multiple linear regression analysis was conducted to test associations of medical variables and response behavior. Correlations between variables and domains, as well as individual items, were assessed using Spearman rank test. RESULTS: A total of 75 patients from Germany who were treated with breathing-synchronized HNS were enrolled (mean age 57.3 years, 78% male), and 71 questionnaires with complete data were included for analysis. Two-thirds of participants (67%) had a history of OSA history for 5 years or longer. Of all patients, 76% had normalized OSA symptoms at time of the study (ESS: 6.4 ± 5.0) and 98% reported using stimulation therapy every night. Regression analysis revealed an association of current symptoms measured with ESS and response behavior. Hence, patients with normalized daytime sleepiness reported significantly more positive experience across all domains assessed, compared to patients with residual daytime sleepiness. Overall, only 2% of participants reported side effects that made them reduce or discontinue stimulation therapy. The rate of reported side effects was associated with current symptom control under therapy. CONCLUSIONS: Overall patient-reported experience with breathing-synchronized HNS therapy was positive and high satisfaction with the treatment process was observed. Side effects occurred, but rarely affected subjective use of the therapy or satisfaction. Subjective experience and perception are influenced by residual daytime sleepiness with stimulation therapy.


Assuntos
Distúrbios do Sono por Sonolência Excessiva , Apneia Obstrutiva do Sono , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Nervo Hipoglosso , Qualidade de Vida , Distúrbios do Sono por Sonolência Excessiva/complicações , Medidas de Resultados Relatados pelo Paciente
3.
Am J Otolaryngol ; 45(1): 104053, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37769502

RESUMO

OBJECTIVE: The purpose of this study is to examine how lateral wall collapse affects treatment outcomes for hypoglossal nerve stimulation (HNS) patients. METHODS: Patients (n = 111) queried from a single surgeon's database of HNS cases were divided into groups based on their degree of oropharyngeal lateral wall collapse noted on drug-induced sleep endoscopy (DISE): Complete, Partial, None. For each group, apnea hypopnea index (AHI) reduction, Epworth Sleepiness Scale (ESS) score, stimulation voltage, average nightly usage, need for alternate device configuration/awake sleep endoscopy, and rate of surgical success were collected. Patients with Complete collapse were compared to those with Partial/None via Student's t-tests and Pearson's Chi-square test. RESULTS: Of the 111 eligible patients, 45 had complete, 30 partial, and 36 had no lateral oropharyngeal wall collapse. There were no statistically significant differences found between the Complete and Partial/None groups in terms of age, BMI, sex, AHI (pre and post-op), ESS (pre and post-op), voltage, alternate device configuration, or nightly adherence. Notably, a significantly greater number of the Partial/None group had surgical success (84.84 % vs 66.67 %, p = 0.024). CONCLUSIONS: Patients with Partial/None oropharyngeal collapse were significantly more likely than patients with Complete lateral wall collapse to see surgical success. There are many factors to weigh when assessing a patient's surgical candidacy, it is clear that complete lateral wall collapse at the level of the oropharynx is a negative predictor for success in HNS.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/cirurgia , Nervo Hipoglosso , Orofaringe , Resultado do Tratamento , Endoscopia , Contraindicações
4.
Am J Otolaryngol ; 45(5): 104419, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39053310

RESUMO

PURPOSE: Hypoglossal nerve stimulation (HNS) can be an effective treatment for moderate to severe obstructive sleep apnea (OSA) in positive airway pressure (PAP) intolerant patients. To better understand patient perceptions of HNS therapy, we explored three Facebook groups pertaining to HNS therapy. MATERIALS AND METHODS: A retrospective analysis of Facebook posts from three HNS-related Facebook groups, from October 1, 2022 to October 1, 2023, was performed. Posts were analyzed for author attitude, content (adverse events, inquiries, or sharing information), and the inclusion of media within the post. RESULTS: From 737 Facebook posts, 752 events were identified, predominantly authored by patients or family (99.5 %). Few posts included media attachments (7.3 %), primarily photos (85.5 %). Post tone was mainly neutral (79.4 %), rather than positive (12.9 %) or negative (7.7 %). Most posts (53.6 %) were queries to the Facebook group, as opposed to sharing information (28.9 %) or detailing adverse events (17.6 %). Notably queries posed by Facebook group members included those pertaining to the postoperative recovery course (10.17 %), physical activity restrictions (6.20 %), HNS therapy eligibility (4.71 %), financial considerations (4.22 %), and more. CONCLUSION: Overall, Facebook group members reported a predominantly neutral tone, typically posting queries to the group rather than sharing information or detailing adverse events. These findings illustrate how diverse data sources, such as social media, can enhance our understanding of patient experiences and identify gaps in patient education with HNS therapy.


Assuntos
Terapia por Estimulação Elétrica , Nervo Hipoglosso , Apneia Obstrutiva do Sono , Mídias Sociais , Humanos , Apneia Obstrutiva do Sono/terapia , Estudos Retrospectivos , Terapia por Estimulação Elétrica/métodos , Terapia por Estimulação Elétrica/efeitos adversos , Masculino , Feminino
5.
Am J Otolaryngol ; 45(5): 104391, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39053311

RESUMO

OBJECTIVE: Upper airway stimulation effectively treats patients with obstructive sleep apnea, especially among those with low long-term compliance with continuous positive airway pressure. Traditional methods to implant the hypoglossal nerve stimulator involve retraction of the digastric tendon to identify the nerve and improve exposure for stimulator implantation. Transient submental pain and discomfort are known side effects of the procedure. Placement without retraction provides an alternative approach to minimize postoperative pain. This study compares post-operative pain outcomes of patients in whom the digastric tendon was and was not retracted. METHODS: Retrospective chart review of patients who received the hypoglossal nerve stimulation implant at a single institution between 2017 and 2021. A combination of descriptive and qualitative data, including age, gender, comorbidities, and postoperative symptoms are analyzed to characterize patient outcomes resulting from this intraoperative technique. The categorical and continuous variables were analyzed using chi-squared tests and independent t-tests, respectively. RESULTS: Patients report overall satisfaction after implantation and titration. A total of 108 patients underwent HGNS implantation between September 2017 and January 2021 using the aforementioned techniques. 1.69 % of patients experienced postoperative submental pain as compared to 18.37 % prior to the change in technique (p < 0.01). CONCLUSION: Avoidance of digastric tendon retraction in the implantation of the stimulating lead is a safe and effective technique that reduces postoperative pain and discomfort. Our institution has demonstrated an alternative technique for hypoglossal stimulator implantation which improves perioperative outcomes. LAY SUMMARY: Upper airway stimulation is an effective treatment for obstructive sleep apnea. During surgery, the digastric tendon is often moved to identify the nerve and improve access. This study shows that avoiding digastric tendon movement safely reduces postoperative pain and discomfort. LEVEL OF EVIDENCE: III.


Assuntos
Terapia por Estimulação Elétrica , Nervo Hipoglosso , Dor Pós-Operatória , Apneia Obstrutiva do Sono , Humanos , Nervo Hipoglosso/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/cirurgia , Terapia por Estimulação Elétrica/métodos , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/etiologia , Resultado do Tratamento , Idoso , Tendões/cirurgia , Adulto , Satisfação do Paciente
6.
Pneumologie ; 78(9): 634-648, 2024 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-38914119

RESUMO

OBJECTIVE: To show the importance of hypoglossal nerve stimulation (HGNS) as a treatment method for obstructive sleep apnea (OSA) in the German healthcare context and to better assess the way patients who do not receive adequate care could benefit from HGNS. METHODS: A systematic literature review in the Medline and Cochrane Library literature database was conducted, including publications using different stimulation technologies for HGNS. The efficacy of HGNS was assessed based on patient-relevant outcomes (daytime sleepiness, quality of life), treatment adherence and the apnea-hypopnea index (AHI) and oxygen desaturation index (ODI). The safety of the treatment method was assessed based on adverse events (AEs). RESULTS: Inclusion and analysis of 33 publications: 2 randomized controlled trials (RCTs, level Ib), 1 level IIb trial (n = 1) and 30 level IV trials with a study duration of up to 60 months. The RCTs showed better values for daytime sleepiness and quality of life when using HGNS than in the control group. AHI and ODI showed a deterioration under placebo stimulation or therapy withdrawal in the RCTs. Consistently high adherence was also reported in the long-term course. Severe AEs under HGNS were rare and could usually be resolved by repositioning electrodes or replacing device components. Other AEs were mostly transient or could be resolved by non-invasive measures. All investigated parameters showed similar results in the evaluated studies. The results of different stimulation systems are comparable in type and extent. CONCLUSION: The comprehensive review of the literature shows consistent data that highlight the importance of HGNS as an effective and safe treatment for OSA after unsuccessful CPAP treatment. The evaluation also shows that the different stimulation systems make it possible to better tailor the therapy to the patient's individual requirements. A future systematic evaluation of real-world data on the use of HGNS would help gain additional insights into the relevance of the method in routine clinical practice.


Assuntos
Terapia por Estimulação Elétrica , Nervo Hipoglosso , Apneia Obstrutiva do Sono , Apneia Obstrutiva do Sono/terapia , Humanos , Terapia por Estimulação Elétrica/métodos , Resultado do Tratamento , Masculino , Feminino , Medicina Baseada em Evidências , Qualidade de Vida , Pessoa de Meia-Idade , Prevalência , Adulto , Idoso , Fatores de Risco
7.
J Sleep Res ; 32(1): e13592, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35596592

RESUMO

Hypoglossal nerve stimulation is an established treatment option for obstructive sleep apnea in selected patients. A unilateral hypoglossal nerve stimulation system was approved a decade ago, yet the physiological effect of unilateral hypoglossal stimulation on bilateral tongue motion remains unclear. This study examined how electrode configuration, stimulation cuff position, or body mass index influenced the contralateral genioglossus electromyography (EMG) signal. Twenty-nine patients underwent three EMG recordings in a polysomnographic setting after being implanted with a unilateral hypoglossal nerve stimulator for at least 6 months. The ratio of EMG signals between the ipsi- and contralateral sides was evaluated. No difference in EMG signals was demonstrated based on electrode configurations, stimulation-cuff position, body-mass-index, or sleep apnea severity, even in patients with right tongue protrusion only. Our findings may be explained by a significant level of cross-innervation and by a smaller and less variable circumferential electric field than expected based on prior biophysical models. A patient's individual anatomy needs to be considered during therapy titration in order to achieve an optimal response.


Assuntos
Terapia por Estimulação Elétrica , Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Humanos , Nervo Hipoglosso/fisiologia , Apneia Obstrutiva do Sono/terapia , Eletrodos
8.
Neuroradiology ; 65(10): 1425-1438, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37540288

RESUMO

CT and MRI findings of tongue ptosis and atrophy should alert radiologists to potential pathology along the course of the hypoglossal nerve (cranial nerve XII), a purely motor cranial nerve which supplies the intrinsic and extrinsic muscles of the tongue. While relatively specific for hypoglossal nerve pathology, these findings do not accurately localize the site or cause of denervation. A detailed understanding of the anatomic extent of the nerve, which crosses multiple anatomic spaces, is essential to identify possible underlying pathology, which ranges from benign postoperative changes to life-threatening medical emergencies. This review will describe key imaging findings of tongue denervation, segmental anatomy of the hypoglossal nerve, imaging optimization, and comprehensive imaging examples of diverse pathology which may affect the hypoglossal nerve. Armed with this knowledge, radiologists will increase their sensitivity for detection of pathology and provide clinically relevant differential diagnoses when faced with findings of tongue ptosis and denervation.


Assuntos
Nervo Hipoglosso , Língua , Humanos , Nervo Hipoglosso/anatomia & histologia , Nervo Hipoglosso/patologia , Língua/diagnóstico por imagem , Língua/inervação , Língua/patologia , Imageamento por Ressonância Magnética
9.
Sleep Breath ; 27(2): 519-525, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35622197

RESUMO

BACKGROUND: Hypoglossal nerve stimulator (HGNS) is a therapeutic option for moderate to severe obstructive sleep apnea (OSA). Improved patient selection criteria are needed to target those most likely to benefit. We hypothesized that the pattern of negative effort dependence (NED) on inspiratory flow limited waveforms recorded during sleep, which has been correlated with the site of upper airway collapse, would contribute to the prediction of HGNS outcome. We developed a machine learning (ML) algorithm to identify NED patterns in pre-treatment sleep studies. We hypothesized that the predominant NED pattern would differ between HGNS responders and non-responders. METHODS: An ML algorithm to identify NED patterns on the inspiratory portion of the nasal pressure waveform was derived from 5 development set polysomnograms. The algorithm was applied to pre-treatment sleep studies of subjects who underwent HGNS implantation to determine the percentage of each NED pattern. HGNS response was defined by STAR trial criteria for success (apnea-hypopnea index (AHI) reduced by > 50% and < 20/h) as well as by a change in AHI and oxygenation metrics. The predominant NED pattern in HGNS responders and non-responders was determined. Other variables including demographics and oxygenation metrics were also assessed between responders and non-responders. RESULTS: Of 45 subjects, 4 were excluded due to technically inadequate polysomnograms. In the remaining 41 subjects, ML accurately distinguished three NED patterns (minimal, non-discontinuous, and discontinuous). The percentage of NED minimal breaths was significantly greater in responders compared with non-responders (p = 0.01) when the response was defined based on STAR trial criteria, change in AHI, and oxygenation metrics. CONCLUSION: ML can accurately identify NED patterns in pre-treatment sleep studies. There was a statistically significant difference in the predominant NED pattern between HGNS responders and non-responders with a greater NED minimal pattern in responders. Prospective studies incorporating NED patterns into predictive modeling of factors determining HGNS outcomes are needed.


Assuntos
Terapia por Estimulação Elétrica , Apneia Obstrutiva do Sono , Humanos , Nervo Hipoglosso , Estudos Prospectivos , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia , Polissonografia , Resultado do Tratamento
10.
Sleep Breath ; 27(2): 693-701, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35779166

RESUMO

PURPOSE: Hypoglossal nerve stimulation (HNS) has been shown to treat obstructive sleep apnea (OSA) effectively. The aim of this study was to compare HNS with positive airway pressure (PAP) treatment regarding outcome parameters: (1) sleepiness, (2) apnea-hypopnea index (AHI), and (3) effectiveness. METHODS: Propensity score matching with nearest neighbor algorithm was used to compare outcomes of HNS and PAP therapy in a real-world setting. Data were collected at baseline and 12 months after initiating OSA treatment including demographics, Epworth Sleepiness Scale (ESS), AHI, and objective adherence data. To account for overall treatment efficacy, the mean disease alleviation (MDA) was calculated. RESULTS: Of 227 patients who received treatment consecutively, 126 could be matched 1:1 with regard to age, body mass index, and AHI. After matching, no statistically significant differences between the groups were found. A clinically important symptom improvement was seen at 12 months in both cohorts, though there was a greater difference in ESS improvement in patients treated with HNS (8.0 ± 5.1 points vs. 3.9 ± 6.8 points; p = 0.042). In both groups, mean posttreatment AHI was significantly reduced (HNS: 8.1 ± 6.3/h; PAP: 6.6 ± 8.0/h; p < 0.001). Adherence after 12 months among patients treated with HNS was higher than in those receiving PAP therapy (5.0 ± 2.6 h/night; 4.0 ± 2.1 h/night) but not with statistical significance. Overall effectiveness calculated with the MDA was 59% in patients treated with HNS compared to 51% receiving PAP. CONCLUSION: Patients treated with HNS therapy had significantly greater improvements in daytime sleepiness compared to PAP therapy, while the mean reduction of AHI and overall effectiveness were comparable for both treatments. TRIAL REGISTRATION: ClinicalTrial.gov Identifier: NCT03756805.


Assuntos
Terapia por Estimulação Elétrica , Apneia Obstrutiva do Sono , Humanos , Pressão Positiva Contínua nas Vias Aéreas , Nervo Hipoglosso , Modalidades de Fisioterapia , Apneia Obstrutiva do Sono/terapia , Sonolência , Resultado do Tratamento
11.
Eur Arch Otorhinolaryngol ; 280(10): 4627-4639, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37354340

RESUMO

INTRODUCTION: Hypoglossal nerve stimulation (HNS) has recently been introduced as an alternative treatment for patients with OSA. A large number of studies have demonstrated substantial changes in OSA with this therapy by reducing respiratory events and improving symptoms such as daytime sleepiness and quality of life. The objective of this review was to conduct a systematic review and meta-analysis to evaluate patient-reported outcomes and experience with HNS therapy. METHODS: A systematic literature search of MEDLINE, Cochrane, and Web of Science was performed to identify randomized controlled and observational studies reporting subjective outcomes with different HNS systems in patients with OSA. Abstracts of 406 articles were screened and a subset of 55 articles were reviewed for eligibility. Risk of bias was assessed using the ROBINS-I tool. Meta-analysis using RevMan was performed when > 2 studies were identified that reported data on a specific outcome. RESULTS: Thirty-four publications reporting data on 3785 patients with a mean follow-up of 11.8 ± 12.2 months were identified and included in the meta-analysis. The analysis revealed a pooled effect of 4.59 points improvement in daytime sleepiness as measured by the ESS questionnaire (Z = 42.82, p < .001), 2.84 points improvement in daytime functioning as measured by the FOSQ score (Z = 28.38, p < .001), and 1.77 points improvement in sleep quality as measured by the PSQI questionnaire (Z = 2.53, p = .010). Patient-reported experience was consistently positive and revealed additional relevant aspects from this perspective. CONCLUSION: HNS therapy significantly improves quality of life in patients with OSA and reliably produces clinically meaningful effects on daytime sleepiness, daytime functioning, and sleep quality. Treatment regularly meets or exceeds the minimum clinically important differences defined for the respective instruments. Additional research is needed to further investigate effects on quality of life beyond improvements in daytime sleepiness and daytime functioning.


Assuntos
Terapia por Estimulação Elétrica , Nervo Hipoglosso , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/cirurgia , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida
12.
ORL J Otorhinolaryngol Relat Spec ; 85(5): 248-252, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36796344

RESUMO

INTRODUCTION: Upper airway stimulation via the hypoglossal nerve stimulator (HGNS) implant is a surgical method for treating obstructive sleep apnea. However, patients may need the implant removed for a variety of reasons. The purpose of this case series is to assess surgical experiences with HGNS explantation at our institution. We report on surgical approach, overall operative times, operative and postoperative complications, and discuss relevant patient-specific surgical findings when removing the HGNS. METHODS: We performed a retrospective case series of all patients that underwent HGNS implantation at a single tertiary medical center between January 9, 2021, and January 9, 2022. Subjects included adult patients who presented to the sleep surgery clinic of the senior author for surgical management of previously implanted HGNS. Patient clinical history was reviewed to determine the timing of the patient's implant, reasons for explant, and postoperative recovery course. Operative reports were reviewed to determine overall duration of surgery and any associated difficulties or deviations from the general approach. RESULTS: Between January 9, 2021, and January 9, 2022, 5 patients had an explantation of their HGNS implant. Explantation occurred between 8 and 63 months of their original implant surgery. The average operative time from incisional start time to close was 162 min for all cases with a range of 96-345 min. No significant complications were reported including pneumothorax and nerve palsy. CONCLUSION: This reported case series outlines the general steps for Inspire HGNS explantation as well as details the experiences in a case series of 5 subjects explanted over the year at a single institution. The results from the cases suggest that the explantation of the device can be performed efficiently and safely.


Assuntos
Terapia por Estimulação Elétrica , Nervo Hipoglosso , Apneia Obstrutiva do Sono , Adulto , Humanos , Terapia por Estimulação Elétrica/métodos , Nervo Hipoglosso/cirurgia , Nervo Hipoglosso/fisiologia , Polissonografia , Estudos Retrospectivos , Apneia Obstrutiva do Sono/cirurgia
13.
Br J Neurosurg ; 37(3): 391-392, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32654525

RESUMO

Cranial nerve palsies after gunshot injury are not uncommon. We report the mechanism of isolated hypoglossal nerve paralysis caused by a gunshot. We report a 74 years old patient in whom a bullet entered through the right nostril and then ended up right occipital condyle. The only neurologic deficit was tongue deviation which resolved in one week. The bullet was not removed. The effect of clival slope may have an importance in this type of injury.


Assuntos
Doenças dos Nervos Cranianos , Doenças do Nervo Hipoglosso , Traumatismos do Nervo Hipoglosso , Ferimentos por Arma de Fogo , Humanos , Idoso , Traumatismos do Nervo Hipoglosso/complicações , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/diagnóstico por imagem , Ferimentos por Arma de Fogo/cirurgia , Doenças do Nervo Hipoglosso/etiologia , Doenças dos Nervos Cranianos/complicações , Fossa Craniana Posterior/diagnóstico por imagem , Fossa Craniana Posterior/cirurgia , Nervo Hipoglosso/cirurgia , Paralisia/etiologia
14.
Sensors (Basel) ; 23(21)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37960581

RESUMO

A hypoglossal nerve stimulator (HGNS) is an invasive device that is used to treat obstructive sleep apnea (OSA) through electrical stimulation. The conventional implantable HGNS device consists of a stimuli generator, a breathing sensor, and electrodes connected to the hypoglossal nerve via leads. However, this implant is bulky and causes significant trauma. In this paper, we propose a minimally invasive HGNS based on an electrocardiogram (ECG) sensor and wireless power transfer (WPT), consisting of a wearable breathing monitor and an implantable stimulator. The breathing external monitor utilizes an ECG sensor to identify abnormal breathing patterns associated with OSA with 88.68% accuracy, achieved through the utilization of a convolutional neural network (CNN) algorithm. With a skin thickness of 5 mm and a receiving coil diameter of 9 mm, the power conversion efficiency was measured as 31.8%. The implantable device, on the other hand, is composed of a front-end CMOS power management module (PMM), a binary-phase-shift-keying (BPSK)-based data demodulator, and a bipolar biphasic current stimuli generator. The PMM, with a silicon area of 0.06 mm2 (excluding PADs), demonstrated a power conversion efficiency of 77.5% when operating at a receiving frequency of 2 MHz. Furthermore, it offers three-voltage options (1.2 V, 1.8 V, and 3.1 V). Within the data receiver component, a low-power BPSK demodulator was ingeniously incorporated, consuming only 42 µW when supplied with a voltage of 0.7 V. The performance was achieved through the implementation of the self-biased phase-locked-loop (PLL) technique. The stimuli generator delivers biphasic constant currents, providing a 5 bit programmable range spanning from 0 to 2.4 mA. The functionality of the proposed ECG- and WPT-based HGNS was validated, representing a highly promising solution for the effective management of OSA, all while minimizing the trauma and space requirements.


Assuntos
Terapia por Estimulação Elétrica , Apneia Obstrutiva do Sono , Humanos , Terapia por Estimulação Elétrica/métodos , Nervo Hipoglosso , Apneia Obstrutiva do Sono/terapia , Próteses e Implantes , Eletrocardiografia
15.
J Pediatr Nurs ; 68: 24-29, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36328914

RESUMO

PURPOSE: The purpose of this study is to explore the experience of parents in deciding whether to participate in a clinical trial of the insertion of the Hypoglossal Nerve Stimulator (HNS) to treat their adolescent with Down Syndrome (DS) and Obstructive Sleep Apnea (OSA). DESIGN AND METHODS: A qualitative descriptive design with interviews was used to gather parental experiences from those who consented to HNS for their adolescent with DS and OSA. Interviews were conducted, audiotaped, and transcribed. Basic content analysis was followed to interpret the data. Using a process of data debriefing/engagement, codes were generated, and field/reflective notes were used to assure trustworthiness of the data. RESULTS: Parents, 13 mothers/2 fathers, participated. Three themes were identified: Parents experience desperation about acceptance of standard of care for their adolescent with DS and OSA. This desperation led parents to seek information/insights from social media and they came to rely on those sites to explore options, ultimately leading them to HNS clinical trial. Finally, parents had a desire to share experience with HNS implantation. CONCLUSIONS: Parents described being desperate at acceptance of standards of care for OSA. They shifted reliance on experts and parents by searching social media pages to explore options for treatment of OSA. Parents wished to share experiences with the HNS implantation. PRACTICE IMPLICATIONS: Nurses play a role in preparing for the HNS by instructing/educating parents. Nurses can identify supportive social media sites for parents during the HNS decision and suggest ways to measure outcomes of HNS.


Assuntos
Síndrome de Down , Nervo Hipoglosso , Pais , Implantação de Prótese , Apneia Obstrutiva do Sono , Adolescente , Feminino , Humanos , Síndrome de Down/complicações , Síndrome de Down/cirurgia , Terapia por Estimulação Elétrica/métodos , Nervo Hipoglosso/cirurgia , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/cirurgia , Masculino , Pais/psicologia , Ensaios Clínicos como Assunto , Participação do Paciente
16.
Surg Radiol Anat ; 45(3): 297-302, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36723635

RESUMO

PURPOSE: This case report aims to explore a rare combination of findings in a cadaver donor: variant ansa cervicalis, vagus (CN X) and hypoglossal (CN XII) nerve fusion, and extracranial hypoglossal neurofibroma. BACKGROUND: The type of ansa cervicalis variation presented in this report has been documented in less than 1% of described cases. The CN X-CN XII fusion has been reported in one prior study. Additionally, hypoglossal neurofibromas are benign neoplasms of the peripheral nerve sheath. There are only two known cases of extracranial hypoglossal neurofibroma described in the literature. CASE REPORT: The study investigated a swelling of the right CN XII in a 90-year-old female cadaver donor. Detailed dissection, examination of the region, and histopathological analysis of the mass followed. The entire course of CN XII and other cranial nerves were examined to exclude concurrent pathology. A fusiform enlargement of the right CN XII was observed in the submandibular region, measuring ~ 1.27 × 1.27 cm. The superior portion of the right CN XII was fused to the right CN X, exiting the jugular foramen. The superior root of ansa cervicalis, normally a branch of CN XII, was found to arise from CN X on the right side. The left CN XII and CN X were unremarkable. Histopathological examination revealed benign neurofibroma. CONCLUSION: The anatomical variation and rare location of the tumor necessitate further investigation to better understand pathogenesis, clinical correlation, and surgical implications. This study furthers knowledge of this condition and contributes to the currently limited body of research.


Assuntos
Plexo Cervical , Neurofibroma , Feminino , Humanos , Idoso de 80 Anos ou mais , Plexo Cervical/anatomia & histologia , Nervo Vago , Dissecação , Neurofibroma/diagnóstico , Neurofibroma/cirurgia , Cadáver , Nervo Hipoglosso/anatomia & histologia
17.
Laryngorhinootologie ; 102(12): 956-968, 2023 12.
Artigo em Alemão | MEDLINE | ID: mdl-38048773

RESUMO

Hypoglossal stimulation is a safe and effective treatment option for patients with obstructive sleep apnea and unsuccessful PAP therapy. A number of criteria must be met for the indication: proof of failed PAP therapy and ineffectiveness of the other therapy alternatives, AHI of 15-65/h (a relevant number of central and/or mixed apneas should be excluded) and BMI up to max. 35kg/m2. In the case of the respiratory-synchronous and bilateral stimulation system, a complete concentric collapse at the velum level should currently be ruled out in DISE. In the future, stimulation of the branch of the ansa cervicalis innervating the sternothyroid muscle and the ramus internus of the superior laryngeal nerve could open up additional treatment options.


Assuntos
Terapia por Estimulação Elétrica , Apneia Obstrutiva do Sono , Humanos , Polissonografia , Apneia Obstrutiva do Sono/cirurgia , Resultado do Tratamento , Terapia por Estimulação Elétrica/métodos , Nervo Hipoglosso/cirurgia
18.
JAAPA ; 36(12): 24-29, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37989167

RESUMO

ABSTRACT: Obstructive sleep apnea (OSA) is a common chronic condition in which upper airway collapse interferes with breathing during sleep, reducing sleep quality. Untreated OSA can impair a patient's health and quality of life. The recommended first-line treatment for OSA in adults is positive airway pressure, but difficulty tolerating this device limits adherence to treatment for many patients. Treatment with an implanted hypoglossal nerve stimulation (HNS) device is a relatively new second-line option for these patients, and is gaining more widespread use. Clinicians who treat OSA or provide other healthcare services to patients with HNS implants should be familiar with these devices. This article reviews HNS technology and relevant OSA pathophysiology, along with device candidacy criteria, efficacy, risks, and considerations related to use of other medical technologies for patients with HNS implants.


Assuntos
Terapia por Estimulação Elétrica , Apneia Obstrutiva do Sono , Humanos , Adulto , Nervo Hipoglosso , Qualidade de Vida , Apneia Obstrutiva do Sono/terapia , Sono
19.
Rev Med Suisse ; 19(N° 809-10): 58-61, 2023 Jan 18.
Artigo em Francês | MEDLINE | ID: mdl-36660839

RESUMO

Hypoglossal nerve stimulation is an alternative treatment for obstructive sleep apnea syndrome (OSAS) in patients intolerant to CPAP. The INSPIRE system (unilateral hypoglossal nerve stimulation) available since 2014 and the NYXOAH system (bilateral hypoglossal nerve stimulation) available since 2019 help to treat OSAS via activation of the genioglossus muscle causing protrusion of the tongue during sleep. We present in this article the two types of hypoglossal nerve stimulators through a recent review of the literature.


La stimulation du nerf hypoglosse est un traitement alternatif du syndrome d'apnées obstructives du sommeil (SAOS) chez des patients intolérants à la CPAP (Continuous Positive Airway Pressure). Le système INSPIRE (stimulation unilatérale du nerf hypoglosse) disponible depuis 2014, et le système NYXOAH (stimulation bilatérale du nerf hypoglosse), disponible depuis 2019, permettent de traiter le SAOS via une activation du muscle génioglosse, provoquant une protrusion de la langue pendant le sommeil. Nous présentons dans cet article les 2 types de stimulateur du nerf hypoglosse à travers une revue récente de la littérature.


Assuntos
Terapia por Estimulação Elétrica , Apneia Obstrutiva do Sono , Humanos , Nervo Hipoglosso/fisiologia , Apneia Obstrutiva do Sono/terapia , Sono/fisiologia , Pressão Positiva Contínua nas Vias Aéreas
20.
J Neurophysiol ; 128(5): 1133-1142, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35976060

RESUMO

Pompe disease is a lysosomal storage disease resulting from absence or deficiency of acid α-glucosidase (GAA). Tongue-related disorders including dysarthria, dysphagia, and obstructive sleep apnea are common in Pompe disease. Our purpose was to determine if designer receptors exclusively activated by designer drugs (DREADDs) could be used to stimulate tongue motor output in a mouse model of Pompe disease. An adeno-associated virus serotype 9 (AAV9) encoding an excitatory DREADD (AAV9-hSyn-hM3D(Gq)-mCherry, 2.44 × 1010 vg) was administered to the posterior tongue of 5-7-wk-old Gaa null (Gaa-/-) mice. Lingual EMG responses to intraperitoneal injection of saline or a DREADD ligand (JHU37160-dihydrochloride, J60) were assessed 12 wk later during spontaneous breathing. Saline injection produced no consistent changes in lingual EMG. Following the DREADD ligand, there were statistically significant (P < 0.05) increases in both tonic and phasic inspiratory EMG activity recorded from the posterior tongue. Brainstem histology confirmed mCherry expression in hypoglossal (XII) motoneurons in all mice, thus verifying retrograde movement of the AAV9 vector. Morphologically, Gaa-/- XII motoneurons showed histological characteristics that are typical of Pompe disease, including an enlarged soma and vacuolization. We conclude that lingual delivery of AAV9 can be used to drive functional expression of DREADD in XII motoneurons in a mouse model of Pompe disease.NEW & NOTEWORTHY In a mouse model of Pompe disease, lingual injection of adeno-associated virus (AAV) serotype 9 encoding DREADD was histologically verified to produce transgene expression in hypoglossal motoneurons. Subsequent intraperitoneal delivery of a DREADD ligand stimulated tonic and phase tongue motor output.In a mouse model of Pompe disease, lingual injection of adeno-associated virus (AAV) serotype 9 encoding DREADD was histologically verified to produce transgene expression in hypoglossal motoneurons. Subsequent intravenous delivery of a DREADD ligand stimulated tonic and phase tongue motor output.


Assuntos
Drogas Desenhadas , Doença de Depósito de Glicogênio Tipo II , Camundongos , Animais , Doença de Depósito de Glicogênio Tipo II/genética , Doença de Depósito de Glicogênio Tipo II/metabolismo , Doença de Depósito de Glicogênio Tipo II/patologia , alfa-Glucosidases/metabolismo , Ligantes , Dependovirus/genética , Neurônios Motores/metabolismo , Modelos Animais de Doenças , Nervo Hipoglosso/metabolismo