Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.728
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
PLoS Genet ; 18(10): e1010469, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36251690

RESUMO

Meiosis in males of higher dipterans is achiasmate. In their spermatocytes, pairing of homologs into bivalent chromosomes does not include synaptonemal complex and crossover formation. While crossovers preserve homolog conjunction until anaphase I during canonical meiosis, an alternative system is used in dipteran males. Mutant screening in Drosophila melanogaster has identified teflon (tef) as being required specifically for alternative homolog conjunction (AHC) of autosomal bivalents. The additional known AHC genes, snm, uno and mnm, are needed for the conjunction of autosomal homologs and of sex chromosomes. Here, we have analyzed the pattern of TEF protein expression. TEF is present in early spermatocytes but cannot be detected on bivalents at the onset of the first meiotic division, in contrast to SNM, UNO and MNM (SUM). TEF binds to polytene chromosomes in larval salivary glands, recruits MNM by direct interaction and thereby, indirectly, also SNM and UNO. However, chromosomal SUM association is not entirely dependent on TEF, and residual autosome conjunction occurs in tef null mutant spermatocytes. The higher tef requirement for autosomal conjunction is likely linked to the quantitative difference in the amount of SUM protein that provides conjunction of autosomes and sex chromosomes, respectively. During normal meiosis, SUM proteins are far more abundant on sex chromosomes compared to autosomes. Beyond promoting SUM recruitment, TEF has a stabilizing effect on SUM proteins. Increased SUM causes excess conjunction and consequential chromosome missegregation during meiosis I after co-overexpression. Similarly, expression of SUM without TEF, and even more potently with TEF, interferes with chromosome segregation during anaphase of mitotic divisions in somatic cells, suggesting that the known AHC proteins are sufficient for establishment of ectopic chromosome conjunction. Overall, our findings suggest that TEF promotes alternative homolog conjunction during male meiosis without being part of the final physical linkage between chromosomes.


Assuntos
Proteínas de Drosophila , Drosophila melanogaster , Animais , Masculino , Drosophila melanogaster/genética , Drosophila melanogaster/metabolismo , Drosophila/genética , Proteínas de Drosophila/genética , Proteínas de Drosophila/metabolismo , Politetrafluoretileno/metabolismo , Segregação de Cromossomos/genética , Meiose/genética , Cromossomos Sexuais/metabolismo , Pareamento Cromossômico
2.
J Vasc Surg ; 79(1): 24-33, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37734570

RESUMO

OBJECTIVE: Type II endoleak is the most frequent complication after endovascular abdominal aneurysm repair. Polytetrafluoroethylene and polyester (PE) are the two most commonly used graft materials in endovascular aneurysm repair (EVAR) devices. Biological properties of the material might influence the appearance and persistence of type II endoleak (T2EL). Therefore, the aim of this study was to evaluate potential differences in the prevalence of T2EL after EVAR between polytetrafluoroethylene (PTFE) and PE endografts in patients electively treated for an infrarenal abdominal aortic aneurysm. METHODS: A single-center, retrospective, observational study was conducted between January 2011 and January 2022. Preoperative, procedural, and follow-up data were derived from electronic health records. Imaging included computed tomography scans, and/or duplex ultrasound examination. The primary end point was the prevalence of T2EL diagnosed within 1 year after EVAR. Secondary end points included the prevalence of T2EL throughout follow-up, early (≤30 days) and late (>30 days) T2EL, the rate of T2EL disappearance during the follow-up period, the prevalence of type I and III endoleak, and T2EL-related reinterventions. RESULTS: Follow-up was available for 394 patients, 245 in the PE and 149 in the PTFE group. The prevalence of T2EL diagnosed within 1 year after endovascular repair was 11.8% in the PE group and 21.5% in the PTFE group (P = .010). There was no significant difference in early (≤30 days) and late (>30 days) T2EL between groups (P = .270 and P = .311). There was no difference in the freedom from endoleak type II reinterventions between groups (P = .877). CONCLUSIONS: The prevalence of T2EL after elective EVAR is significantly higher with the use of PTFE-based endografts compared with PE-based endografts. This difference is mostly based on T2EL diagnosed after 30 days of follow-up.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/epidemiologia , Endoleak/etiologia , Estudos Retrospectivos , Prevalência , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Politetrafluoretileno
3.
J Vasc Surg ; 79(5): 1240-1250.e4, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38122858

RESUMO

OBJECTIVE: Post implantation syndrome (PIS) is an early systemic inflammatory response following endovascular aortic repair (EVAR). The response is variable in patients and the clinical significance of PIS upon outcomes is unknown. This study aims to evaluate the incidence, risk factors, and prognostic implication of PIS. METHODS: Systematic literature review and analysis was performed in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) and Cochrane guidelines of PubMed, Scopus, ClinicalTrials.gov, and the Cochrane Central Register of Controlled Trials. Eligible English-language studies regarding PIS after infrarenal EVAR were included, after removing duplicates. RESULTS: After screening, 31 studies were included. A total of 2847 patients were reviewed, with mean age of 70.7 years, of which 2012 (90.4%) were male, with a pooled mean follow-up of 26.1 months. PIS was reported in 25.3% of cases, with mean aneurysm diameter of 56.4 cm. Polytetrafluoroethylene (PTFE) grafts were utilized in 794 patients (27.9%) with polyester in 1839 (64.6%). White blood cell count, C-reactive protein, interleukin (IL)-6, IL-8, and IL-10 levels were all significantly elevated postoperatively. Thirty-day outcomes included type I endoleak rate of 0.8%, type II endoleak rate of 1.7%, reintervention rate of 0.35%, and mortality rate of 0.25%. Subgroup pooled analysis of patients with PIS (n = 309) vs No-PIS (n = 691) revealed that polyester (n = 642), rather than PTFE (n = 234) grafts, were associated with a higher rate of PIS (94.8% vs 3.7%; P = .0001), White blood cell count was higher in the PIS group both preoperatively (7.61 vs 6.76 × 109/L; P = .04) and postoperatively (15.0 vs 9.8 × 109/L; P = .0007) and IL-6 levels were higher in the PIS group postoperatively (98.6 vs 25.2 pg/mL; P = .02). Aneurysm diameter and amount of chronic or new thrombus within the aneurysm sac was not identified as a risk factor for PIS. Pooled outcomes of patients with PIS vs No-PIS demonstrated a significantly higher rate of 30-day mortality (0.6% vs 0%; P = .03) and major adverse cardiac events (5.8% vs 0.43%; P < .0001) without any differences seen in reintervention or 30-day type I or type II endoleaks. CONCLUSIONS: This systematic review suggests that polyester grafts are strongly associated with PIS compared with PTFE. Interestingly, this report is suggestive of an association between 30-day mortality and major adverse cardiac events and PIS. Given these clinical sequelae, consideration for use of PTFE over polyester grafts to reduce the incidence of PIS may be a simple step to improve overall outcome. Further, exploration of the relationship between inflammatory mediators associated with PIS and mortality and cardiac complications may engender deeper understanding of risks, leading to eventual mitigation of harm for patients experiencing PIS.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Feminino , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Endoleak/complicações , Resultado do Tratamento , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Procedimentos Endovasculares/efeitos adversos , Fatores de Risco , Poliésteres , Politetrafluoretileno , Estudos Retrospectivos
4.
J Vasc Surg ; 80(4): 1090-1096.e1, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38909917

RESUMO

OBJECTIVE: Hemodialysis access-induced distal ischemia (HAIDI) is a known complication of hemodialysis (HD) access. Distal revascularization and interval ligation (DRIL) is the preferred treatment for HAIDI by many surgeons. Proximalization of arterial inflow (PAI) is a promising alternative technique that, unlike DRIL, preserves the native arterial inflow. The purpose of this study is to report our experience with PAI on a series of 64 patients. METHODS: This is a single-center, retrospective cohort study of patients with both arteriovenous (AV) fistulas and grafts who underwent PAI for HAIDI from 2017 to 2023. A 4 × 7 tapered polytetrafluoroethylene (PTFE) graft was used to connect HD access inflow to the axillary artery in the majority of cases. The primary outcome of the study is resolution of HAIDI (complete, partial, or no resolution). Secondary outcomes include functional patency (primary and secondary) and 30-day complications following PAI. RESULTS: Of the 71 patients identified to have had PAI between May 2017 to August 2023, seven were lost to follow-up. In total, 64 patients were included, with an average age of 65 years (standard deviation, 15 years), 59.4% (38/64) female, and 37.5% (24/64) African American. The study population was notable for numerous comorbid conditions including 95.3% (61/64) hypertension; 50% (32/64) coronary artery disease; 79.7% (51/64) diabetes; and 43.8% (28/64) smoking history. Following PAI intervention for HAIDI, 55 of 64 patients (85.9%) experienced complete resolution of ischemic symptoms; five of 64 patients (7.8%) had partial resolution; two of 64 patients (3.1%) had no resolution, and two of 64 patients (3.1%) had unknown resolution. Primary patency at 1, 12, and 24 months was 94%, 81%, and 71%, respectively. Secondary patency at 1, 12, and 24 months was 97%, 87%, and 84%, respectively. The 30-day complication rate was 10.9% (7/64), with five of 64 (7.8%) thromboses, one of 64 (1.6%) thrombosis and infection, and one of 64 (1.6%) upper extremity swelling secondary to central venous stenosis (resolved with angioplasty of central venous system). Failure rate due to thrombosis at 12 and 24 months was 14% (9/64) and 15.6% (10/64), respectively. CONCLUSIONS: Our study, the largest case series of PAI to date, demonstrates that PAI is a reliable option for HAIDI intervention and has comparable safety and efficacy results to DRIL, despite the use of a synthetic graft. Furthermore, PAI has the added benefit of maintaining the native arterial pathway. Further investigation of PAI is warranted as a promising alternative to DRIL for HAIDI management.


Assuntos
Derivação Arteriovenosa Cirúrgica , Implante de Prótese Vascular , Prótese Vascular , Isquemia , Diálise Renal , Grau de Desobstrução Vascular , Humanos , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Isquemia/fisiopatologia , Isquemia/etiologia , Isquemia/terapia , Isquemia/cirurgia , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Fatores de Tempo , Politetrafluoretileno , Fluxo Sanguíneo Regional , Fatores de Risco , Extremidade Superior/irrigação sanguínea , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/terapia , Artéria Axilar/cirurgia , Artéria Axilar/fisiopatologia
5.
J Vasc Surg ; 79(6): 1447-1456.e2, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38310981

RESUMO

OBJECTIVE: Inadequate vein quality or prior harvest precludes use of autologous single segment greater saphenous vein (ssGSV) in many patients with chronic limb-threatening ischemia (CLTI). Predictors of patient outcome after infrainguinal bypass with alternative (non-ssGSV) conduits are not well-understood. We explored whether limb presentation, bypass target, and conduit type were associated with amputation-free survival (AFS) after infrainguinal bypass using alternative conduits. METHODS: A single-center retrospective study (2013-2020) was conducted of 139 infrainguinal bypasses performed for CLTI with cryopreserved ssGSV (cryovein) (n = 71), polytetrafluoroethylene (PTFE) (n = 23), or arm/spliced vein grafts (n = 45). Characteristics, Wound, Ischemia, and foot Infection (WIfI) stage, and outcomes were recorded. Multivariable Cox proportional hazards and classification and regression tree analysis modeled predictors of AFS. RESULTS: Within 139 cases, the mean age was 71 years, 59% of patients were male, and 51% of cases were nonelective. More patients undergoing bypass with cryovein were WIfI stage 4 (41%) compared with PTFE (13%) or arm/spliced vein (27%) (P = .04). Across groups, AFS at 2 years was 78% for spliced/arm, 79% for PTFE, and 53% for cryovein (adjusted hazard ratio for cryovein, 2.5; P = .02). Among cases using cryovein, classification and regression tree analysis showed that WIfI stage 3 or 4, age >70 years, and prior failed bypass were predictive of the lowest AFS at 2 years of 36% vs AFS of 58% to 76% among subgroups with less than two of these factors. Although secondary patency at 2 years was worse in the cryovein group (26% vs 68% and 89% in arm/spliced and PTFE groups; P < .01), in patients with tissue loss there was no statistically significant difference in wound healing in the cryovein group (72%) compared with other bypass types (72% vs 87%, respectively; P = .12). CONCLUSIONS: In patients with CLTI lacking suitable ssGSV, bypass with autogenous arm/spliced vein or PTFE has superior AFS compared with cryovein, although data were limited for PTFE conduits for distal targets. Despite poor patency with cryovein, wound healing is achieved in a majority of cases, although it should be used with caution in older patients with high WIfI stage and prior failed bypass, given the low rates of AFS.


Assuntos
Amputação Cirúrgica , Salvamento de Membro , Doença Arterial Periférica , Veia Safena , Cicatrização , Humanos , Masculino , Estudos Retrospectivos , Feminino , Idoso , Veia Safena/transplante , Fatores de Risco , Fatores de Tempo , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/mortalidade , Pessoa de Meia-Idade , Medição de Risco , Politetrafluoretileno , Idoso de 80 Anos ou mais , Isquemia Crônica Crítica de Membro/cirurgia , Prótese Vascular , Enxerto Vascular/efeitos adversos , Enxerto Vascular/mortalidade , Enxerto Vascular/métodos , Grau de Desobstrução Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Intervalo Livre de Progressão , Criopreservação , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 104(2): 247-251, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38860616

RESUMO

In the absence of standardized management guidelines, coronary artery aneurysms (CAAs) present therapeutic challenges. Percutaneous coronary intervention (PCI) is rarely explored, especially in giant aneurysms with persistent angina, where surgery might be presumed as a preferred option. We describe the technical aspects and feasibility of PCI using Gore Viabahn expanded polytetrafluoroethylene (ePTFE)-covered nitinol self-expanding stents in a 66-year-old woman with a complex medical history and an enlarging, symptomatic right coronary artery aneurysm. The case was complicated by endoleak after the first stent, but intravascular ultrasound guidance enabled the precise deployment of additional stents, resulting in the successful exclusion of the aneurysm. This case demonstrates steps to successful CAA PCI with Gore Viabahn ePTFE-covered nitinol self-expanding stents and emphasizes that in unsuitable surgical candidates, PCI might be a potential alternative for symptomatic CAAs.


Assuntos
Ligas , Aneurisma Coronário , Desenho de Prótese , Ultrassonografia de Intervenção , Humanos , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/cirurgia , Aneurisma Coronário/terapia , Idoso , Feminino , Resultado do Tratamento , Stents Metálicos Autoexpansíveis , Angiografia Coronária , Politetrafluoretileno , Intervenção Coronária Percutânea/instrumentação , Stents , Angioplastia Coronária com Balão/instrumentação
7.
Catheter Cardiovasc Interv ; 104(2): 264-271, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38973374

RESUMO

Patients with functionally univentricular hearts are usually palliated surgically. There have been several reports of successful attempts to complete the Fontan procedure without surgery. The pathways created at the time of the preconditioning were largely reminiscent of the lateral tunnel Fontan. However, this approach is still confidentially limited to a small number of centers. In 2013, we designed a circuit that mimics the actual surgical technique of extracardiac total cavopulmonary connection to allow for transcatheter completion in an animal study. A polytetrafluoroethylene conduit was connected between the pulmonary artery and the inferior vena cava (IVC). The superior anastomosis was occluded to avoid flow between IVC and superior vena cava (SVC). The conduit was connected to the right atrium (RA) and a large fenestration was created to allow free flow from the IVC to the RA. Extrapolating our approach, a center reported the successful transcatheter completion of an extracardiac Fontan in a 6-year-old child. However, this technique is not directly transposable to our population of patients who require preconditioning in infancy. We report here an innovative extension of this technique that may allow preparing patients in infancy, ideally at the time of the Glenn in the future, to receive an extracardiac Fontan at 2 years/11 kg without additional surgery.


Assuntos
Cateterismo Cardíaco , Técnica de Fontan , Cardiopatias Congênitas , Técnica de Fontan/efeitos adversos , Cateterismo Cardíaco/instrumentação , Humanos , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/diagnóstico por imagem , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Veia Cava Inferior/fisiopatologia , Politetrafluoretileno , Coração Univentricular/cirurgia , Coração Univentricular/fisiopatologia , Coração Univentricular/diagnóstico por imagem , Desenho de Prótese , Resultado do Tratamento , Hemodinâmica , Animais , Prótese Vascular
8.
Langmuir ; 40(27): 13810-13818, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38918081

RESUMO

The friction of solids is primarily understood through the adhesive interactions between the surfaces. As a result, slick materials tend to be nonstick (e.g., Teflon), and sticky materials tend to produce high friction (e.g., tires and tape). Paradoxically, cartilage, the slippery bearing material of human joints, is also among the stickiest of known materials. This study aims to elucidate this apparent paradox. Cartilage is a biphasic material, and the most cited explanation is that both friction and adhesion increase as load transfers from the pressurized interstitial fluid to the solid matrix over time. In other words, cartilage is slippery and sticky under different times and conditions. This study challenges this explanation, demonstrating the strong adhesion of cartilage under high and low interstitial hydration conditions. Additionally, we find that cartilage clings to itself (a porous material) and Teflon (a nonstick material), as well as other surfaces. We conclude that the unusually strong interfacial tension produced by cartilage reflects suction (like a clingfish) rather than adhesion (like a gecko). This finding is surprising given its unusually large roughness, which typically allows for easy interfacial flow and defeats suction. The results provide compelling evidence that cartilage, like a clingfish, conforms to opposing surfaces and effectively seals submerged contacts. Further, we argue that interfacial sealing is itself a critical function, enabling cartilage to retain hydration, load support, and lubrication across long periods of inactivity.


Assuntos
Cartilagem Articular , Cartilagem Articular/química , Animais , Fricção , Lubrificação , Propriedades de Superfície , Adesividade , Politetrafluoretileno/química
9.
J Surg Res ; 300: 352-362, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38843722

RESUMO

INTRODUCTION: This study aims to assess the association of operative time with the postoperative length of stay and unplanned return to the operating room in patients undergoing femoral to below knee popliteal bypasses, stratified by autologous vein graft or polytetrafluoroethylene (PTFE). MATERIALS AND METHODS: A retrospective analysis of vascular quality initiative database (2003-2021). The selected patients were grouped into the following: vein bypass (group I) and PTFE (group II) patients. Each group was further stratified by a median split of operative time (i.e., 210 min for autologous vein and 155 min for PTFE) to study the outcomes. The outcomes were assessed by univariate and multivariate approach. RESULTS: Of the 10,902 patients studied, 3570 (32.7%) were in the autologous vein group, while 7332 (67.3%) were in the PTFE group. Univariate analysis revealed autologous vein and PTFE graft recipients that had increased operative times were associated with a longer mean postoperative length of stay and a higher incidence of all-cause return to the operating room. In PTFE group, patients with prolonged operative times were also found to be associated with higher incidence of major amputation, surgical site infection, and cardiovascular events, along with loss of primary patency within a year. CONCLUSIONS: For patients undergoing femoral to below knee popliteal bypasses using an autologous vein or PTFE, longer operative times were associated with inferior outcomes. Mortality was not found to be associated with prolonged operative time.


Assuntos
Tempo de Internação , Extremidade Inferior , Duração da Cirurgia , Politetrafluoretileno , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Extremidade Inferior/cirurgia , Extremidade Inferior/irrigação sanguínea , Tempo de Internação/estatística & dados numéricos , Resultado do Tratamento , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/mortalidade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/mortalidade , Veias/transplante , Veias/cirurgia , Enxerto Vascular/métodos , Enxerto Vascular/estatística & dados numéricos , Enxerto Vascular/efeitos adversos , Enxerto Vascular/mortalidade
10.
J Vasc Interv Radiol ; 35(3): 362-369, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38123126

RESUMO

PURPOSE: To determine time to occlusion and procedure costs of embolization of pulmonary arteriovenous malformations (PAVMs) using a polytetrafluoroethylene-covered microplug compared with embolization using detachable coils. MATERIALS AND METHODS: In this prospective study, 37 patients (mean age, 39.1 years [SD ± 17.6]) with 82 PAVMs underwent embolization with microplug or detachable coils between April 2019 and January 2023. Technical success, procedure time intervals, and costs were analyzed. RESULTS: In 37 patients, 82 PAVMs and 101 feeding arteries were successfully treated (microplug, 64; microplug + another device, 5; detachable coils alone, 32). Time from embolic device inserted into the catheter to device deployed and time to occlusion differed significantly between microplug and detachable coil cohorts (P < .0001 for both). Embolization with ≥1 microplug had a significantly shorter occlusion time than embolization with detachable coils (median, 10.0 minutes saved per feeding artery) (P < .0001). Compared with detachable coil embolization, microplug embolization saved a median of 9.0 minutes per feeding artery (P < .0001) and reduced room cost by a median of $429 per feeding artery (P < .0001). Device costs per feeding artery did not differ significantly between microplug ($2,790) and detachable coil embolization ($3,147) (P = .87). CONCLUSIONS: Compared with coils, microplugs had an equally high technical success rate but significant time to occlusion and room costs savings per feeding artery. Total room cost and device cost together did not differ significantly between microplugs and coils. Microplugs may be considered technically effective and at least cost-neutral for PAVM embolization where clinically appropriate.


Assuntos
Fístula Arteriovenosa , Malformações Arteriovenosas , Embolização Terapêutica , Artéria Pulmonar/anormalidades , Veias Pulmonares , Veias Pulmonares/anormalidades , Humanos , Adulto , Estudos Prospectivos , Politetrafluoretileno , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , Fístula Arteriovenosa/terapia , Embolização Terapêutica/métodos , Artéria Pulmonar/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Resultado do Tratamento
11.
Environ Sci Technol ; 58(1): 925-934, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38117535

RESUMO

Hydrogen peroxide (H2O2), as a critical green chemical, has received immense attention in energy and environmental fields. The ability to produce H2O2 in earth-abundant water without relying on low solubility oxygen would be a sustainable and potentially economic process, applicable even to anaerobic microenvironments, such as groundwater treatment. However, the direct water to H2O2 process is currently hindered by low selectivity and low production rates. Herein, we report that poly(tetrafluoroethylene) (PTFE), a commonly used inert polymer, can act as an efficient triboelectric catalyst for H2O2 generation. For example, a high H2O2 production rate of 24.8 mmol gcat-1 h-1 at a dosage of 0.01 g/L PTFE was achieved under the condition of pure water, ambient atmosphere, and no sacrificial agents, which exceeds the performance of state-of-the-art aqueous H2O2 powder catalysts. Electron spin resonance and isotope experiments provide strong evidence that water-PTFE tribocatalysis can directly oxidize water to produce H2O2 under both anaerobic and aerobic conditions, albeit with different synthetic pathways. This study demonstrates a potential strategy for green and effective tribocatalytic H2O2 production that may be particularly useful toward environmental applications.


Assuntos
Peróxido de Hidrogênio , Oxigênio , Polímeros , Água , Politetrafluoretileno
12.
Environ Sci Technol ; 58(26): 11606-11614, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38874561

RESUMO

Global atmospheric emissions of perfluorocyclobutane (c-C4F8, PFC-318), a potent greenhouse gas, have increased rapidly in recent years. Combining atmospheric observations made at nine Chinese sites with a Lagrangian dispersion model-based Bayesian inversion technique, we show that PFC-318 emissions in China grew by approximately 70% from 2011 to 2020, rising from 0.65 (0.54-0.72) Gg year-1 in 2011 to 1.12 (1.05-1.19) Gg year-1 in 2020. The PFC-318 emission increase from China played a substantial role in the overall increase in global emissions during the study period, contributing 58% to the global total emission increase. This growth predominantly originated in eastern China. The regions with high emissions of PFC-318 in China overlap with areas densely populated with polytetrafluoroethylene (PTFE) factories, implying that fluoropolymer factories are important sources of PFC-318 emissions in China. Our investigation reveals an emission factor of approximately 3.02 g of byproduct PFC-318 emissions per kg of hydrochlorofluorocarbon-22 (HCFC-22) feedstock use in the production of tetrafluoroethylene (TFE) (for PTFE production) and hexafluoropropylene (HFP) if we assume all HCFC-22 produced for feedstock uses in China are pyrolyzed to produce PTFE and HFP. Further facility-level sampling and analysis are needed for a more precise evaluation of emissions from these factories.


Assuntos
Poluentes Atmosféricos , Atmosfera , China , Poluentes Atmosféricos/análise , Atmosfera/química , Monitoramento Ambiental , Fluorocarbonos/análise , Teorema de Bayes , Politetrafluoretileno , Ciclobutanos
13.
Clin Oral Implants Res ; 35(2): 167-178, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37987205

RESUMO

OBJECTIVES: The goal of this study was to assess the newly formed bone and the remnant biomaterial by comparing four different bone grafts used to treat critical-size defects, associated or not with the non-resorbable membrane. MATERIALS AND METHODS: Two calvaria critical-size bone defects were created in 50 male Wistar rats. They were divided into blood (G1), autogenous (G2), bioglass (G3), hydroxyapatite (G4), and xenograft (G5) groups, associated or not with e-PTFE. The experimental periods were 15 and 45 days. Sections were prepared for histomorphometric assessment. All data were analyzed by the mixed-effects model with multiple comparisons (significance level, p < .05). RESULTS: A similar level of new bone was observed for all groups, associated with a high level of vascularization. G1 and G2 ensured sovereignty over the greater quantity of new bone. A non-significant result was reported comparing groups with and without membranes. No significant result was found between the experimental synthetic biomaterials (G3 and G4). G5L achieved 22.0% of new bone after 45 days (p > .05). All groups had a stable volume of biomaterial kept in the short term (p > .05). G2 was the best material for new bone formation and final volume of biomaterial, followed by G4 < G5 < G3. Thus, it is possible that G4 had a better degradation profile among the experimental groups. CONCLUSIONS: The best results were found in the autogenous group, with higher resorption and integration; non-significative new bone was found among the experimental groups; and the regeneration of critical bone defects using an e-PTFE barrier did not present significant results on new bone formation.


Assuntos
Materiais Biocompatíveis , Crânio , Humanos , Ratos , Animais , Masculino , Ratos Wistar , Materiais Biocompatíveis/farmacologia , Crânio/cirurgia , Osteogênese , Politetrafluoretileno , Regeneração Óssea
14.
Ann Vasc Surg ; 98: 201-209, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37355019

RESUMO

BACKGROUND: To analyze the outcomes of heparin-bonded expanded polytetrafluoroethylene (HePTFE) graft as an alternative conduit in infrapopliteal revascularization of chronic limb-threatening ischemia (CLTI) in the absence of an autologous vein conduit. METHODS: A single-center retrospective analysis of patients with CLTI submitted to infrapopliteal bypasses with autologous vein graft (VEIN group) or HePTFE graft (HePTFE group) was implemented. Primary end points were freedom from CLTI at 12 months and recurrence of CLTI at 3 years. Secondary end points included freedom from major amputation, amputation-free survival (AFS), survival, and primary (PP) and secondary patency (SP) rates at 3 years of follow-up. RESULTS: A total of 348 limbs submitted to infrapopliteal bypasses, 214 with venous graft and 134 with HePTFE graft, were followed-up for a median of 25 months. Most patients of the HePTFE group were male (69%), with a median age of 76 years (interquartile range [IQR] 15). Fifty-nine percent of the limbs of the HePTFE group had Wound grade ≥2, being 46% of them infected. Eighty-eight percent were GLASS stage III. Freedom from CLTI was not significantly different between HePTFE and VEIN groups (75% vs. 84%, adjusted hazard ratio [aHR] 0.88, confidence interval [CI] 0.66-1.18, P = 0.401). Recurrence of CLTI was higher in the HePTFE group (42% vs.18% at 3 years; aHR 2.82, CI 1.59-5.00, P < 0.001). The VEIN group achieved higher rates of freedom from major amputation (87% vs.69% at 3 years; aHR 2.21, CI 1.31-3.75, P = 0.003) and AFS (59% vs. 37% at 3 years; aHR 1.39, CI 1.02-1.88, P = 0.036), but no significance in survival (aHR 1.10, CI 0.72-1.66, P = 0.667). Patency rates were inferior in the HePTFE group, with 2-year PP and SP rates of 52% vs. 74%, and 76% vs. 90%, respectively (PP: aHR 1.70, CI 1.11-2.59, P = 0.014; SP: aHR 2.51, CI 1.42-4.42, P = 0.001). CONCLUSIONS: Infrapopliteal bypass with autologous vein graft is the gold standard to treat CLTI limbs. HePTFE graft should be regarded as an alternative for complex infrapopliteal revascularization when lacking an autologous vein conduct.


Assuntos
Implante de Prótese Vascular , Heparina , Humanos , Masculino , Idoso , Feminino , Heparina/efeitos adversos , Anticoagulantes , Politetrafluoretileno , Estudos Retrospectivos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Grau de Desobstrução Vascular , Resultado do Tratamento , Isquemia/diagnóstico por imagem , Isquemia/cirurgia , Salvamento de Membro , Fatores de Risco
15.
Ann Vasc Surg ; 105: 236-251, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38582218

RESUMO

BACKGROUND: Heparin-bonded expanded polytetrafluoroethylene (hb-ePTFE) synthetic grafts are an alternative to autologous vein grafts (AVG) for surgical bypass interventions in lower limb peripheral arterial disease (LLPAD). However, the clinical benefits of hb-ePTFE grafts have not been reviewed systematically for patients undergoing below-the-knee (BK) surgical bypass. This study aimed to meta-analyze available data on the utility of hb-ePTFE in patients undergoing BK surgical bypass. METHODS: Medline, Embase, and Cochrane databases were searched, restricted to material in English with no date restriction. In addition, proceedings from relevant congresses were screened going back 2 years. The search was performed in December 2021. Eligible studies included prospective or retrospective comparative studies or prospective single-arm cohorts with an hb-ePTFE arm. Methodological quality was assessed with the ROBINS-I criteria. Outcomes included primary patency, amputation/limb salvage, and overall survival. Clinical outcomes were expressed as event rates. Studies were compared using meta-analysis to generate a standardized mean event rate for each outcome, with its 95% confidence interval (95% CI), using a random-effects model. RESULTS: Following deduplication, 10,263 records were identified and 261 were assessed as full texts. No prospective comparative studies were identified. The level of evidence was uniformly low. Seventeen publications describing data from 9 individual patient cohorts met the inclusion criteria. These cohorts included a total of 1,452 patients undergoing BK surgical bypass with hb-ePTFE. The primary patency rate was 78.9% [95% CI: 72.2-85.7%] at 1 year, 68.2% [95% CI: 62.8-73.6%] at 2 years, decreasing to 48.0% [95% CI: 27.3-68.7%] at 5 years. The secondary patency rate was 84.8% [95% CI: 77.0-92.5%] at 1 year and 68.9% [95% CI: 43.0-94.9%] at 3 years; the 1-year limb salvage rate was 88.3% [95% CI: 79.6-97.1%] at 1 year and 79.0% [95% CI: 56.7-100%] at 3 years. CONCLUSIONS: In patients undergoing BK bypass surgery, hb-ePTFE synthetic grafts, compared to uncoated grafts, perform well for patency and limb salvage. However, the quality of the evidence is low, and well-performed randomized clinical trials are needed to inform clinical decision-making on the choice of synthetic graft.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Artéria Femoral , Heparina , Salvamento de Membro , Doença Arterial Periférica , Politetrafluoretileno , Desenho de Prótese , Grau de Desobstrução Vascular , Humanos , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Heparina/efeitos adversos , Heparina/administração & dosagem , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Artéria Femoral/cirurgia , Artéria Femoral/fisiopatologia , Idoso , Masculino , Resultado do Tratamento , Anticoagulantes/administração & dosagem , Feminino , Fatores de Risco , Fatores de Tempo , Materiais Revestidos Biocompatíveis , Pessoa de Meia-Idade , Amputação Cirúrgica , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Medição de Risco , Idoso de 80 Anos ou mais
16.
Ann Vasc Surg ; 106: 273-283, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38821469

RESUMO

BACKGROUND: The heparin-bonded expanded polytetrafluoroethylene (He-ePTFE) conduit is an option for patients requiring infrainguinal revascularization (iIR), but the risk of failure may be unpredictable, especially in cases with poor run-off. Intraoperative transit-time flow (TTF) provides an automated and quantitative analysis of flow and may serve as an adjunct evaluation during surgical revascularization. The aim of this study was to assess TTF in patients undergoing iIR with He-PTFE at 3 referral hospitals and to establish a predictive flow threshold for graft occlusion. METHODS: A prospective registry initiated in 2020 enrolled patients undergoing iIR using He-PTFE for critical limb ischemia or severe claudication, and TTF measurement was analyzed. Preoperative assessments of anatomical and clinical characteristics were available for all patients. The HT353 Optima Meter (Transonic Systems Inc., Ithaca, NY, USA) was used in all procedures according to a standardized protocol. The institutional ethics committee approved the study. A predictive model using receiver operating characteristic curve analysis was utilized to establish the threshold of flow, and variables were compared. Anatomical and clinical evaluation were reported according to Rutherford grade, Global Limb Anatomic System and Wound, Ischemia, and foot Infection classification. The main outcome considered was the correlation between TTF and graft occlusion. Secondary outcomes included survival, other predictors of graft occlusion, freedom from major adverse cardiovascular events, and freedom from major amputation. RESULTS: Among 68 patients, 55.8% had Rutherford 5-6, 45.6% had Global Limb Anatomic System 3 and 73.5% had Wound, Ischemia, and foot Infection 3-4. Distal anastomosis was at tibial level in 23.5% and mean diameter of conduit was 6.4 mm. Basal and postoperative TTF were 27.8 ± 15.6 ml/min and 109.0 ± 53.0 ml/min, respectively. After a mean follow-up of 18 ± 13 months, 7 (10.9%) patients presented graft occlusion and 5 (7.8%) required major amputation. TTF threshold = 80 ml/min revealed a sensitivity and specificity of 81.8% (95% confidence interval 48.2-97.7) and 80.7% (95% confidence interval 68.1-90.0) respectively, and it was selected as cut-off for graft occlusion. Freedom from graft occlusion in patients with TTF >80 ml/min vs. TTF ≤80 ml/min at 6, 12, and 24 months was 95.7% (standard error (SE) = 0.030) vs. 65.5% (SE = 0.115), 95.7% (SE = 0.030) vs. 58.9% (SE = 0.120) and 90.9% (SE = 0.054) vs. 51.6% (SE = 0.126), P = 0.0003. No statistical difference in primary patency, secondary patency and limb salvage was observed. At multivariate analysis, distal anastomosis at tibial vessel (odds ratio 8.50) and TTF ≤80 ml/min (odds ratio 9.39) were independent predictors of graft occlusion. CONCLUSIONS: These results suggest that TTF may serve as a valuable tool in the management of iIR. A TTF measurement of ≤80 ml/min should be regarded as a predictor of graft occlusion, prompting consideration of additional intraoperative maneuvers to enhance arterial flow. Caution should be exercised in patients requiring direct tibial artery revascularization, as it represents a predictor of failure independent of TTF levels. Larger cohorts of patients and longer follow-up periods are necessary to confirm these findings.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Oclusão de Enxerto Vascular , Heparina , Isquemia , Doença Arterial Periférica , Politetrafluoretileno , Valor Preditivo dos Testes , Desenho de Prótese , Fluxo Sanguíneo Regional , Sistema de Registros , Grau de Desobstrução Vascular , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Heparina/administração & dosagem , Heparina/efeitos adversos , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/diagnóstico por imagem , Fatores de Tempo , Fatores de Risco , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Isquemia/fisiopatologia , Isquemia/cirurgia , Isquemia/diagnóstico , Isquemia/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Materiais Revestidos Biocompatíveis , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Estado Terminal , Salvamento de Membro , Falha de Tratamento , Amputação Cirúrgica , Medição de Risco , Claudicação Intermitente/fisiopatologia , Claudicação Intermitente/cirurgia , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/diagnóstico
17.
Retina ; 44(2): 360-363, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37972943

RESUMO

PURPOSE: To report a novel technique for refixation of dislocated CZ70BD intraocular lens (IOL). METHODS: Vitrectomy trocars are placed along the horizontal meridian 5 mm apart. A CV-8 Gore-Tex suture is introduced through a bare sclerotomy into the midvitreous cavity. Under chandelier illumination, a 27 G broad platform forceps is threaded through the eyelet of the dislocated CZ70BD IOL. Using another pair of intraocular forceps, the free intraocular end of the Gore-Tex suture is fed to the broad platform forceps and externalized, thus repositioning the IOL. Particular attention is drawn to pass the suture in an over and under configuration to avoid IOL tilt. An identical procedure is repeated for the other eyelet if the IOL is completely dislocated. The 23 gauge or 25 gauge instruments should not be used for this technique because they do not fit loosely through the eyelets of the IOL. RESULTS: Three eyes were successfully operated on using this technique with at least 6 months of follow-up. There was significant improvement in best-corrected visual acuity after the operation. Postoperative IOL centration and alignment were satisfactory. CONCLUSION: The described surgical technique is effective for transscleral Gore-Tex-assisted refixation of dislocated CZ70BD IOL.


Assuntos
Lentes Intraoculares , Humanos , Implante de Lente Intraocular/métodos , Acuidade Visual , Politetrafluoretileno , Esclera/cirurgia , Suturas , Técnicas de Sutura , Estudos Retrospectivos
18.
Acta Neurochir (Wien) ; 166(1): 239, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38814504

RESUMO

BACKGROUND: Microvascular conflicts in hemifacial spasm typically occur at the facial nerve's root exit zone. While a pure microsurgical approach offers only limited orientation, added endoscopy enhances visibility of the relevant structures without the necessity of cerebellar retraction. METHODS: After a retrosigmoid craniotomy, a microsurgical decompression of the facial nerve is performed with a Teflon bridge. Endoscopic inspection prior and after decompression facilitates optimal Teflon bridge positioning. CONCLUSIONS: Endoscope-assisted microsurgery allows a clear visualization and safe manipulation on the facial nerve at its root exit zone.


Assuntos
Espasmo Hemifacial , Cirurgia de Descompressão Microvascular , Politetrafluoretileno , Humanos , Espasmo Hemifacial/cirurgia , Cirurgia de Descompressão Microvascular/métodos , Nervo Facial/cirurgia , Craniotomia/métodos , Endoscopia/métodos , Neuroendoscopia/métodos , Microcirurgia/métodos , Feminino , Pessoa de Meia-Idade , Masculino
19.
Altern Ther Health Med ; 30(1): 434-440, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37820674

RESUMO

Objective: The center of the face plays an important role in the fullness of our facial contours, however, sunken center of the face is more common in Asians than in Europeans and Americans. Expanded polytetrafluoroethylene (PTFE) and rib cartilage are commonly used to fill the nasal base to improve the hollowing of the center of the face. This study aimed to compare the efficacy and safety of crescent-shaped expanded polytetrafluoroethylene (e-PTFE) with granulated rib cartilage for nasal base filling to treat midface depressions. Methods: Fifty-one patients with mild to moderate midface depression and normal occlusion admitted to our department from June 2017 to August 2020 were selected. Comprehensive rhinoplasty was performed, which included nasal base filling using crescentic e-PTFE or granulated rib cartilage. They are all women, with an average age of 27.4 years. The e-PTFE group (group A) had 27 cases, while the granulated rib cartilage group (group B) had 24. Changes in two face parameters, the wing ear line and facial convexity, were measured and recorded based on preoperative and postoperative photographs of the patients and using 3D imaging technology. Postoperative complications and satisfaction were assessed by questionnaires to compare the two surgical approaches' differences, advantages, and disadvantages. Results: Postoperative midface depression improved significantly in 51 patients. Most of the patients who underwent both procedures showed significant improvement in the wing ear line and facial convexity. The 3D imaging has also helped us to more objectively assess the changes in midface concavity. Some patients experienced acute discomfort, such as foreign body sensation and stiffness in the surgical area, for the first three months after nasal base filler surgery. Still, these symptoms resolved on their own within six months. Most patients (92.6% in group A and 91.6% in group B) felt that they had natural facial expressions and were satisfied with the filler results. Conclusion: The use of crescentic e-PTFE and granular rib cartilage to fill the nasal base is easy to operate and has a quick postoperative recovery, allowing for good postoperative results. However, after some of the granular rib cartilage filling treatments, the height of the nasal base was lowered, which may be connected to its limited structural support, ease of displacement, and resorption. Crescentic e-PTFE is superior to granular rib cartilage in terms of both morphology and mechanical support. The crescentic e-PTFE filling method provides rapid postoperative recovery and good shape maintenance, but local stiffness is more pronounced than in the granular rib cartilage group. This may help the plastic surgeon's choice of surgical procedure.


Assuntos
Cartilagem Costal , Rinoplastia , Humanos , Feminino , Adulto , Politetrafluoretileno , Depressão , Rinoplastia/métodos , Complicações Pós-Operatórias/cirurgia , Costelas/cirurgia
20.
Int J Urol ; 31(9): 1017-1021, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38840427

RESUMO

OBJECTIVE: Transvaginal mesh surgery for pelvic organ prolapse has been widely performed in Japan, but polypropylene mesh has not been used in Japan since the ban on TVM using polypropylene mesh in the United States. Currently, polytetrafluoroethylene mesh ORIHIME® is the only mesh available for TVM in Japan. Although polytetrafluoroethylene is a safe material, its low coefficient of friction and insufficient adhesion to the surrounding tissue make it difficult to maintain the mesh position when it is used in the transvaginal mesh surgery. The aim of this study was to evaluate the feasibility of TVM-A2 using ORIHIME®. METHODS: One hundred cases of TVM-A2 were included in the study. The patients were randomly assigned to two groups: the ORIHIME® group (Group O) and the PolyformTM group (Group P). With 50 patients in each group, the complications and recurrences up to the fourth year were compared. Surgeries were performed using the TVM-A2 method. Statistical analysis was performed using EZR. RESULTS: There were no significant differences in baseline parameters between the two groups. We observed no perioperative complications, and saw one case of postoperative abscess formation in Group O, which resolved successfully after incision and drainage. The 4-year recurrence rate was significantly higher in Group O. CONCLUSION: As the recurrence rate was significantly higher in Group O, we conclude that TVM-A2 using ORIHIME® which is the same procedure as TVM-A2 using polypropylene mesh is not feasible in repairing the pelvic organ prolapse.


Assuntos
Estudos de Viabilidade , Prolapso de Órgão Pélvico , Politetrafluoretileno , Telas Cirúrgicas , Humanos , Feminino , Prolapso de Órgão Pélvico/cirurgia , Idoso , Telas Cirúrgicas/efeitos adversos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Japão , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA