Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J. appl. oral sci ; 28: e20200343, 2020. graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1143144

RESUMO

Abstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology: Volumetric and linear (central and marginal) gaps of four Ti-base abutments (n=10/group): (i) Odontofix LTDA (OD), (ii) Singular Implants (SING), (iii) EFF Dental Components (EFF), and (iv) Control Group (S.I.N implants) compatible with an implant system (Strong SW, S.I.N Implants) were measured using μCT reconstructed polyvinyl siloxane replicas. Results: The results showed significantly lower volume gap for Control S.I.N (0.67±0.29 mm3) and SING (0.69±0.28 mm3) Ti-base abutments relative to OD (1.42±0.28 mm3) and EFF groups (1.04±0.28 mm3) (p<0.033), without significant difference between them (p=0.936). While gap values were homogenous in the central region, EFF presented a significantly higher marginal gap. Accordingly, the Control S.I.N and Singular Ti-base abutments showed improved volumetric and marginal fit relative to Odontofix and EFF. Conclusion: The method of manufacturing abutments influenced the misfit at the implant-abutment interface.


Assuntos
Implantes Dentários , Dente Suporte , Titânio , Técnicas de Réplica , Microtomografia por Raio-X , Projeto do Implante Dentário-Pivô
2.
Braz. oral res. (Online) ; 32: e005, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889474

RESUMO

Abstract Optical coherence tomography (OCT) has generally been used as a nondestructive technique to evaluate integrities of composite restorations. We investigated marginal and internal adaptations of ceramic inlay restorations with OCT and compared them to results with the silicone replica technique. Round-shaped class I cavities were prepared on 16 human maxillary first premolar teeth. Ceramic inlays were fabricated. Silicone replicas from inlays were obtained and sectioned to measure marginal and internal adaptations with a stereomicroscope (Leica Dfc 295, Bensheim, Germany). Inlays were cemented on respective teeth. Marginal and internal adaptations were then measured with the OCT system (Thorlabs, New Jersey, USA) in 200- μm intervals. Replica and OCT measurements were compared with independent samples t-tests. A paired t-test was used to evaluate the marginal and internal adaptations of each group (p < 0.05). Marginal and internal adaptations were 100.97 ± 31.36 and 113.94 ± 39.75 μm, respectively, using the replica technique and 28.97 ± 17.86 and 97.87 ± 21.83 μm, respectively, using OCT. The differences between the techniques were significant (p = 0.00 and p = 0.01, respectively). On evaluation within the groups, internal adaptation values were found to be significantly higher than the marginal adaptation values for the replica technique (p = 0.00) and OCT (p = 0.00). Therefore, the replica and OCT techniques showed different results, with higher values of marginal and internal adaptation found with the replica technique. Marginal and internal adaptation values of ceramic inlays, whether measured by replica or OCT techniques, were within clinically acceptable limits.


Assuntos
Humanos , Cerâmica/química , Adaptação Marginal Dentária , Restaurações Intracoronárias/métodos , Técnicas de Réplica/métodos , Tomografia de Coerência Óptica/métodos , Teste de Materiais , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Cimentos de Resina/química , Propriedades de Superfície
3.
J. appl. oral sci ; 26: e20160590, 2018. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-893721

RESUMO

Abstract The aim of this in vitro study was to assess the reliability of two measurement systems for evaluating the marginal and internal fit of dental copings. Material and Methods: Sixteen CAD/CAM titanium copings were produced for a prepared maxillary canine. To modify the CAD surface model using different parameters (data density; enlargement in different directions), varying fit was created. Five light-body silicone replicas representing the gap between the canine and the coping were made for each coping and for each measurement method: (1) light microscopy measurements (LMMs); and (2) computer-assisted measurements (CASMs) using an optical digitizing system. Two investigators independently measured the marginal and internal fit using both methods. The inter-rater reliability [intraclass correlation coefficient (ICC)] and agreement [Bland-Altman (bias) analyses]: mean of the differences (bias) between two measurements [the closer to zero the mean (bias) is, the higher the agreement between the two measurements] were calculated for several measurement points (marginal-distal, marginal-buccal, axial-buccal, incisal). For the LMM technique, one investigator repeated the measurements to determine repeatability (intra-rater reliability and agreement). Results: For inter-rater reliability, the ICC was 0.848-0.998 for LMMs and 0.945-0.999 for CASMs, depending on the measurement point. Bland-Altman bias was −15.7 to 3.5 μm for LMMs and −3.0 to 1.9 μm for CASMs. For LMMs, the marginal-distal and marginal-buccal measurement points showed the lowest ICC (0.848/0.978) and the highest bias (-15.7 μm/-7.6 μm). With the intra-rater reliability and agreement (repeatability) for LMMs, the ICC was 0.970-0.998 and bias was −1.3 to 2.3 μm. Conclusion: LMMs showed lower interrater reliability and agreement at the marginal measurement points than CASMs, which indicates a more subjective influence with LMMs at these measurement points. The values, however, were still clinically acceptable. LMMs showed very high intra-rater reliability and agreement for all measurement points, indicating high repeatability.


Assuntos
Técnicas de Réplica/métodos , Planejamento de Prótese Dentária/métodos , Desenho Assistido por Computador , Adaptação Marginal Dentária/normas , Modelos Dentários/normas , Microscopia/métodos , Padrões de Referência , Valores de Referência , Titânio/química , Variações Dependentes do Observador , Reprodutibilidade dos Testes
4.
Rio de Janeiro; s.n; 2014. 51 p. ilus.
Tese em Português | LILACS, BBO | ID: biblio-911069

RESUMO

Este estudo avaliou os assentamentos marginal e interno em 4 áreas predeterminadas de coroas totais à base de dissilicato de lítio produzidas por 3 fluxos de trabalho distintos. Um modelo-mestre de titânio com um preparo para coroa total em um molar foi confeccionado. Foram produzidas 36 coroas totais à base de dissilicato de lítio. As coroas foram divididas em 3 grupos, de acordo com o fluxo de trabalho: Totalmente Convencional (TC): moldagem do modelo-mestre com polieter, vazagem com gesso tipo IV e confecção de 12 coroas (IPS e.max PRESS) no laboratório de prótese; Totalmente Digital (TD): escaneamento do modelo-mestre com a Bluecam™ e usinagem de 12 coroas totais (IPS e.max CAD™) no CEREC 3™; e Parcialmente Digital (PD): moldagem do modelo-mestre com polieter, vazagem com gesso tipo IV, escaneamento do modelo de gesso com a Bluecam™ e usinagem de 12 coroas totais (IPS e.max CAD™) no CEREC 3™. Para a avaliação do assentamento foi utilizada a técnica da réplica, onde a base leve do silicone de adição simulou um cimento. Duas réplicas por coroa total foram confeccionadas, gerando imagens de interfaces vestíbulo-palatal e mesio-distal sob magnificação de 50x. Quatro áreas foram definidas para a avaliação: Abertura Marginal (AM); Chanfro (CH); Parede Axial (PA); e Parede Oclusal (PO). Um software realizou a medição dos valores em toda a área demarcada, gerando aproximadamente 6.000 pontos de avaliação por interface. Os resultados foram estatisticamente analisados por meio dos testes One-Way-Anova e Scheafer's Post-Hoc, com grau de significância estabelecido em 5%. Todas os grupos testados no estudo apresentaram médias de valores clinicamente aceitáveis para os assentamentos marginal e interno. Não houve diferença significativa em AM, CH e PO entre os três grupos testados. Em PA, o grupo TC apresentou valores significativamente maiores do que PD e TD (p = 0,001). Os diferentes fluxos de trabalho, convencional ou digitais, aplicados neste estudo, foram capazes de prover adequados assentamentos marginal e interno, dentro dos valores clínicos estabelecidos para coroas totais à base de porcelana.


The aim of this study was to evaluate the marginal and internal fit of porcelain indirect restorations produced by three distinct workflows in four pre-determined interface areas. A titanium master model - simulating a full crown molar preparation - was built to this study. 36 lithium dissilicate full crowns coverage were produced. The restorations were divided in 3 groups, according to the workflow: Totally Conventional (TC), where a polieter impression of the master model was poured with type IV gypsum, and 12 full crown coverages (IPS e.max PRESS™) were produced in the dental technician; Totally Digital (TD), where the master model was scanned with the Bluecam™ and 12 full crown coverages (IPS e.max CAD™) were milled in the CEREC 3™; Partially Digital (PD), where a polieter impression of the master model was poured with type IV gypsum, with the Bluecam™ scanning the working model and the 12 full crown coverages (IPS e.max CAD™) being milled by the CEREC 3™. The replica technique, where the light body silicone simulate the cement, was used to evaluate the fit of the crowns. Two cross sectioned replicas per crown were obtained, generating images of the bucco-palatal and mesio-distal interfaces under 50x magnification. Four interface areas were choosen to the evaluation: Marginal Opening (AM); Chamfer (CH), Axial Wall (PA); and Occlusal Wall (PO). The hole interface area of each image was evaluated, generating approximately 6.000 points to be rated per interface. Results were statistical analyzed with one-way-Anova and Scheafer's post hoc with a 5% level of significance. All the 3 tested groups showed clinically acceptable mean values for marginal and internal fit. For the areas AM, CH and PO, similar results were found between the 3 groups. For the PA area, TC group showed significantely higher values than PD and TD groups (p = 0,001). The different workflows, conventional or digitals, used in this study were proven capable to present elegible marginal and internal fit, based on the accepted current values for porcelain full coverage crowns.


Assuntos
Cimentação/métodos , Cerâmica , Coroas , Dentística Operatória , Desenho Assistido por Computador , Adaptação Marginal Dentária , Lítio/uso terapêutico , Técnicas de Réplica
5.
Braz. dent. j ; 13(2): 75-85, 2002.
Artigo em Inglês | LILACS | ID: lil-332156

RESUMO

This is a preliminary study to determine a methodological sequence in vitro which may allow the reproduction of dentin for SEM analysis, after the use of different desensitizing agents. Dentin discs obtained from extracted human third molars were etched with 6 citric acid, an artificial smear layer was created and the surface dentin discs were divided into four quadrants. Quadrants 2, 3 and 4 of each disc were conditioned with 6 citric acid. The desensitizing agents (Oxa-Gel, Gluma Desensitizer and an experimental agent) were applied to quadrants 3 and 4. To evaluate the acid resistance of the treatment, quadrant 4 was etched again with 6 citric acid. An impression was then taken with Aquasil ULV. After a setting period of 6 min, each disc was removed from the impression and stored in a moist-free environment for 24 h at 37 degrees C. After that time, a low-viscosity epoxy resin (Araltec GY 1109 BR) was poured into the impression and cured for 24 h. All specimens were metal-coated for SEM analysis. Comparison of the photomicrographs of dentin discs with their respective impressions and resin replicas showed that this technique can reproduce the characteristics of the dentin surface treated with desensitizing agents.


Assuntos
Humanos , Dentina , Sensibilidade da Dentina , Substâncias Protetoras , Condicionamento Ácido do Dente , Fosfatos de Cálcio , Celulose , Ácido Cítrico , Dentina , Sensibilidade da Dentina , Resinas Epóxi , Glutaral , Ouro , Materiais para Moldagem Odontológica/química , Metacrilatos , Microscopia Eletrônica de Varredura , Oxalatos , Técnicas de Réplica , Camada de Esfregaço , Propriedades de Superfície , Temperatura , Fatores de Tempo
6.
Claves odontol ; 13(58): 42-48, jul. 2006. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-447192

RESUMO

Las investigaciones han hecho del alginato un material aceptable para los más variados casos clínicos. Sin embargo, en la observación clínica, la acción de la presión atmosférica reducida que ocurre en el interior de la impresión, en el momento de su remoción,es lo que produce un arrastre del material que puede ser traducido, bajo ciertas circunstancias, en una alteración permanente. En este sentido, el objetivo del presente estudio fue analizar estas alteraciones en réplicas obtenidas de una matriz, por medio de una impresión, utilizando el alginato Hydrogum y medirlas a través del programa AutoCAD. Los resultados mostraron que los modelos obtenidos de la impresión con ese alginato presentaron valores de sus ángulos mayores que los de la matriz y que las cribas realizadas en la cubeta no siempre ofrecen los mejores resultados


Assuntos
Alginatos , Coloides , Materiais para Moldagem Odontológica/química , Técnicas de Réplica , Interpretação Estatística de Dados , Técnica de Moldagem Odontológica/instrumentação
7.
JBC j. bras. clin. odontol. integr ; 9(49): 113-121, abr.-jun. 2005. ilus
Artigo em Português | LILACS, BBO | ID: lil-472498

RESUMO

A Microscopia Eletrônica de Varredura apresenta algumas desvantagens como a formação de trincas ou contração do dente durante seu preparo, assim como a impossibilidade de realizar observações in vivo. Para diminuir estes problemas, têm-se desenvolvido técnicas de replicação, avaliando a cópia e não o dente, o que permite estudar processos e seqüências de tratamento na mesma amostra, tanto in vitro como in vivo. Dessa forma, a proposição deste trabalho é avaliar morfologicamente a fidelidade de uma técnica de replicação, utilizando 2 resinas epóxicas e uma técnica de moldagem em dentes humanos extraídos. Uma vez eliminado o cemento no terço cervical radicular dos dentes com alta rotação, delimitou-se uma área de 4X4 na qual foi aplicado EDTA-T 24% por 3 minutos, seguindo da lavagem com soro e secagem com jato de ar, expondo túbulos dentinários. Estes seguimentos foram moldados, utilizando silicona de adição Aquasil (pesada e leve). Posteriormente, as moldagens foram vazadas com as resinas CMR 028-endurecedor CME-251 (Polipox, São Paulo) e o Epoxiglass 1504 e endurecedor 1603 (Epoxiglass-SP). Todas as réplicas e dentes naturais foram avaliados no MEV tomando fotomicrografias que foram avaliadas de acordo com o grau de fidelidade na réplica dos túbulos dentinários. Os resultados mostraram que a técnica de replicação reproduziu satisfatoriamente as características da superfície dentária.


Assuntos
Dentina , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Técnicas de Réplica/métodos , Resinas Acrílicas , Técnica de Moldagem Odontológica
8.
JBP, j. bras. odontopediatr. odontol. bebê ; 4(21): 405-10, set.-out. 2001. ilus, CD-ROM
Artigo em Português | LILACS, BBO | ID: biblio-852061

RESUMO

O objetivo deste artigo é apresentar a indicação da técnica da Réplica Oclusal, como uma alternativa para restaurações em resina composta de lesões de cárie oculta na face oclusal de molares decíduos. Essa técnica visa a reprodução da superfície oclusal, utilizando uma matriz confeccionada de resina fotopolimerizável, Fermit© (Vivadent), de forma a facilitar a conformação anatômica original do dente. As principais vantagens seriam: o restabelecimento da forma e função com reprodução fiel da anatomia oclusal, diminuição do tempo clínico e preservação de estrutura dental sadia


Assuntos
Humanos , Masculino , Pré-Escolar , Cárie Dentária/terapia , Técnicas de Réplica , Restauração Dentária Permanente , Dente Decíduo , Dente Molar
9.
Rev. Asoc. Odontol. Argent ; 91(5): 461-465, oct.-dic. 2003. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-353426

RESUMO

El objetivo de este trabajo fue evaluar la acción de los primers autoacondicionantes sobre esmalte bovino sin cortar, mediante la observación de réplicas al MEB. Se evaluaron el Self-etching bond (Kuraray) y el Prompt-L pop (3M-Espe), y se compararon con el grupo de control con ácido fosfórico al 35 por ciento + single bond. Las réplicas mostraron que la acción del adhesivo autoacondicionante difiere de uno a otro y depende en gran medida de la composición del mismo. La presencia de esmalte aprismático dificulta la acción del adhesivo. El patrón más evidente se logró con el Prompt-L pop, el Self-etching bond produjo un patrón aceptable pero poco profundo y con precipitado de cristales embebidos en resina sobre la superficie. La utilización de grabado ácido previo a la colocación de los adhesivos autoacondicionantes en esmalte sin cortar favorece la obtención de un patrón de grabado más profundo. En conclusión, los primers autoacondicionantes no producen aún una efectiva penetración en esmalte aprismático


Assuntos
Animais , Bovinos , Colagem Dentária , Esmalte Dentário , Condicionamento Ácido do Dente/instrumentação , Bovinos , Resinas Compostas , Esmalte Dentário , Dentina , Incisivo , Microscopia Eletrônica de Varredura , Patente , Técnicas de Réplica , Camada de Esfregaço
10.
Claves odontol ; 10(52): 3-7, abr.-mayo 2003. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-349311

RESUMO

La problemática que plantea el reducido espesor de tejidos dentarios en elementos primarios, amplitud y escasa profundidad cavitaria, junto a la necesidad de buscar una "integración diente-restauración", con la mejor adaptacion, sellado marginal, baja incidencia de caries secundaria y la amplia gama de materiales restauradores que nos ofrece el mercado odontológico, motivó la realización del presente trabajo. El propósito de este estudio fue comprobar el grado de adaptación marginal por medio de microscopía electrónica de barrido (M.E.B.). Se emplearon 36 molares temporarios superiores y/o inferiores, recientemente extraídos. Se realizaron prepraaciones cavitarias clase I. Aleatoriamente fueron divididos en 6 grupos según el material restaurador: Grupo I: amalgama convencional; Grupo II: amalgama adherida; grupo III: resina compuesta; Grupo IV: cermet; grupo V: vitro-ionómero-resina; grupo VI: compómero. Posterioremente se obtuvieron réplicas que fueron metalizadas y analizadas con microscopía electrónica de barrido, a diferentes magnificaciones. Las mediciones se realizaron a nivel del BCP, tercio medio de las paredes de contorno y del ángulo axiopulpar. Las pruebas de comparaciones múltiples mostraron que el mejor comportamiento correspondió al compómero, con un valor medio de adaptación de 0,86_m, seguido del grupo III y V con 0,88_m y 1,14_m respectivamente. Los valores medios para el grupo II y IV fueron de 1,31_m en la amalgama adherida y 1,69_m para el cermet. El análisis de varianza determinó que la zona del ángulo axiopulpar mostró la más alta desadaptación en todos los materiales con diferencias significativas (p<0,0005) con respecto al BCP y pared axial que no difieren significativamente entre sí. Puede concluirse que las diferencias histológicas de los elementos temporarios con respecto a los permanentes y las dificultades en la estabilización de uniones fuertes a la dentina primaria serían la causa de las significativamente más bajas fuerzas de adhesión de los sistemas utilizados sobre todo a nivel del ángulo axiopulpar


Assuntos
Adaptação Marginal Dentária , Materiais Dentários , Restauração Dentária Permanente/instrumentação , Dente Decíduo , Análise de Variância , Cimentos de Ionômeros de Vidro/química , Cimentos Cermet , Compômeros/química , Resinas Compostas , Amálgama Dentário , Colagem Dentária , Dentina , Teste de Materiais , Microscopia Eletrônica de Varredura , Dente Molar , Fotomicrografia , Preparo da Cavidade Dentária/métodos , Técnicas de Réplica , Interpretação Estatística de Dados , Dente Decíduo
11.
Bauru; s.n; 2002. 197 p. ilus. (BR).
Tese em Português | LILACS, BBO | ID: lil-329364

RESUMO

O presente trabalho teve como objetivo avaliar in vitro e in vivo, através de uma técnica de réplica associada à microscopia eletrônica de varredura (MEV), as características e modificaçöes da superfície da dentina hiperestésica e tratada com um agente dessensibilizante à base de oxalato de potássio. O estudo in vitro foi realizado utilizando-se discos de dentina, cuja superfície foi condicionada com ácido cítrico a 6 por ecnto, coberta com smear layer artificial e dividida em 4 quadrantes. A smear layer foi mantida no quadrante 1, considerado o controle para a dentina näo exposta. Os quadrantes 2, 3 e 4 de cada disco foram recondicionados com ácido cítrico a 6 por cento, e o oxalato de potássio foi aplicado nos quadrantes 3 e 4. O quadrante 4 foi, entäo, novamente condicionado com ácido cítrico a 6 por cento. Feita a moldagem com Aquasil ULV, removeu-se o disco do molde após 6 minutos. Decorridas 24 horas, uma resina epóxica de baixa viscosidade foi vazada sobre o molde, e deixada polimerizar por outras 24 horas. Os discos de dentina, moldes e réplicas de resina epóxica foram metalizados para análise no MEV. No estudo in vivo, os pacientes, cujos dentes caninos e pré-molares apresentavam lesöes cervicais näo cariosas e sensíveis aos estímulos sonda e/ou jato de ar conforme a Escala Visual Analógica (EVA), foram selecionados e divididos em 2 grupos. No baseline, após o registro da sensibilidade em ambos os grupos, a superfície de dentina foi limpa com hipoclorito de sódio a 1 por cento, e 3 moldagens consecutivas foram realizadas, sendo a primeira para remoçäo de debris, e as outras, para obtençäo das réplicas positivas e negativas. Os moldes foram armazenados por um período de 24 horas em local fechado, seco e limpo, e a resina epóxica foi, entäo, vazada. O Grupo 1 (16 dentes) recebeu 4 aplicaçöes de Oxa-Gel© em intervalos de 7 dias. No Grupo 2 (7 dentes), nenhum agente anti-hiperestésico foi aplicado. Após 4 semanas, reavaliou-se o grau de sensibilidade


Assuntos
Humanos , Sensibilidade da Dentina , Técnicas In Vitro , Oxalatos , Dentina , Hiperestesia , Técnicas de Réplica
12.
Lima; s.n; 1993. 42 p. tab, graf. (3701).
Monografia em Espanhol | LILACS | ID: lil-187046

RESUMO

Se comprobó el efecto inductor mutagénico de la luz uv, obteniendo mutantes auxotróficos y morfológicos de salmonella typhimurium. El aislamiento de mutantes auxotróficos mediante la técnica de réplica en placa mejora con el uso de penicilina mediante el método de Hollyday, para la identificación de los requerimientos específicos de cada mutante, se caracterizó 3 mutantes auxotróficos de 24 mutantes escogidos al azar. De 24 mutantes auxotróficos, el 30 por ciento resultó ser metronina dependientes, y 25 por ciento revirtieron la características de mutantes auxotróficos.


Assuntos
Salmonella typhimurium/química , Salmonella typhimurium/classificação , Salmonella typhimurium/crescimento & desenvolvimento , Salmonella typhimurium/isolamento & purificação , Salmonella typhimurium/virologia , Penicilinas/isolamento & purificação , Técnicas de Réplica/tendências , Técnicas de Réplica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA