Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.574
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
N Engl J Med ; 384(4): 335-344, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33503342

RESUMO

BACKGROUND: In the United States, more intrauterine device (IUD) users select levonorgestrel IUDs than copper IUDs for long-term contraception. Currently, clinicians offer only copper IUDs for emergency contraception because data are lacking on the efficacy of the levonorgestrel IUD for this purpose. METHODS: This randomized noninferiority trial, in which participants were unaware of the group assignments, was conducted at six clinics in Utah and included women who sought emergency contraception after at least one episode of unprotected intercourse within 5 days before presentation and agreed to placement of an IUD. We randomly assigned participants in a 1:1 ratio to receive a levonorgestrel 52-mg IUD or a copper T380A IUD. The primary outcome was a positive urine pregnancy test 1 month after IUD insertion. When a 1-month urine pregnancy test was unavailable, we used survey and health record data to determine pregnancy status. The prespecified noninferiority margin was 2.5 percentage points. RESULTS: Among the 355 participants randomly assigned to receive levonorgestrel IUDs and 356 assigned to receive copper IUDs, 317 and 321, respectively, received the interventions and provided 1-month outcome data. Of these, 290 in the levonorgestrel group and 300 in the copper IUD group had a 1-month urine pregnancy test. In the modified intention-to-treat and per-protocol analyses, pregnancy rates were 1 in 317 (0.3%; 95% confidence interval [CI], 0.01 to 1.7) in the levonorgestrel group and 0 in 321 (0%; 95% CI, 0 to 1.1) in the copper IUD group; the between-group absolute difference in both analyses was 0.3 percentage points (95% CI, -0.9 to 1.8), consistent with the noninferiority of the levonorgestrel IUD to the copper IUD. Adverse events resulting in participants seeking medical care in the first month after IUD placement occurred in 5.2% of participants in the levonorgestrel IUD group and 4.9% of those in the copper IUD group. CONCLUSIONS: The levonorgestrel IUD was noninferior to the copper IUD for emergency contraception. (Supported by the Eunice Kennedy Shriver National Institute of Child Health and Human Development and others; ClinicalTrials.gov number, NCT02175030.).


Assuntos
Anticoncepção Pós-Coito/métodos , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Levanogestrel/administração & dosagem , Adolescente , Adulto , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Gravidez , Taxa de Gravidez , Testes de Gravidez , Sexo sem Proteção , Adulto Jovem
2.
Anal Bioanal Chem ; 416(18): 4101-4109, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38744719

RESUMO

Reproductive management significantly impacts dairy farm productivity, necessitating accurate timely pregnancy detection in cattle. This paper presents a novel handheld and portable fluorescence imaging system designed for quantitative assessment of pregnancy-specific biomarkers, addressing the limitations of current detection methods. The objective was to develop a cost-effective, at-farm solution for detecting pregnancy-specific protein B (PSPB) in bovine plasma samples. The system integrates an imaging module and a custom software application, enabling image capture, data processing, and PSPB concentration determination. Calibration utilizing known PSPB concentrations achieved a 0.6 ng/mL limit of detection. Validation encompassed a comparison with a standard ELISA method using 100 bovine plasma samples; minimal bias and good agreement were observed within the linear range of the calibration curve for both methods. The system offers portability, user-friendliness, and potential for multiplex detection, promising real-time, at-farm reproductive management. This study demonstrates the successful development and validation of a portable fluorescence imaging system, offering an efficient and accurate approach to detecting pregnancy-specific biomarkers in cattle. Its implications extend to improving dairy farm productivity by enabling timely and reliable reproductive management practices.


Assuntos
Biomarcadores , Imagem Óptica , Animais , Bovinos , Feminino , Gravidez , Biomarcadores/sangue , Biomarcadores/análise , Imagem Óptica/métodos , Imagem Óptica/instrumentação , Limite de Detecção , Testes de Gravidez/métodos , Testes de Gravidez/veterinária , Testes de Gravidez/instrumentação , Proteínas da Gravidez/sangue , Proteínas da Gravidez/análise , Desenho de Equipamento , Ensaio de Imunoadsorção Enzimática/métodos
3.
Anesth Analg ; 138(5): 980-991, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37801601

RESUMO

Respect for patient autonomy is a pillar of medical ethics, manifested predominantly through informed consent. Mandatory (routine) nonconsented preoperative urine pregnancy testing does not adequately respect patient autonomy, is potentially coercive, and has the potential to cause harm medically, psychologically, socially, and financially. Inaccuracies in pregnancy testing can result in false-positive and false-negative results, especially in early pregnancy. There is substantial scientific evidence that anesthesia is not harmful to the fetus, raising the question of whether pregnancy testing provides substantial benefit to the patient. Not performing a preanesthesia pregnancy test has not been associated with significant medicolegal consequences. We review the ethical implications of mandatory preanesthesia pregnancy testing in light of these facts.


Assuntos
Consentimento Livre e Esclarecido , Testes de Gravidez , Gravidez , Feminino , Humanos
4.
BMC Public Health ; 24(1): 1742, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38951787

RESUMO

BACKGROUND: Many women in low- and middle-income countries, including Kenya, access antenatal care (ANC) late in pregnancy. Home pregnancy testing can enable women to detect pregnancy early, but it is not widely available. Our study explored the acceptability and potential of home pregnancy testing delivered by community health volunteers (CHV) on antenatal care initiation in rural Kenya. METHODS: This study was part of a public health intervention to improve uptake and quality of ANC. Between November and December 2020, we conducted 37 in-depth interviews involving women who tested positive or negative for a urine pregnancy test provided by CHVs; CHVs and their supervisors involved in the delivery of the pregnancy tests; facility healthcare workers; and key informants. Using Sekhon et al.'s framework of acceptability, the interviews explored participants' perceptions and experiences of home pregnancy testing, including acceptability, challenges, and perceived effects on early ANC uptake. Data were analysed thematically in NVivo12 software. RESULTS: Home pregnancy testing was well-received by women who trusted test results and appreciated the convenience and autonomy it offered. Adolescents cherished the privacy, preferring home testing to facility testing which could be a stigmatising experience. Testing enabled earlier pregnancy recognition and linkage to ANC as well as reproductive decision-making for those with undesired pregnancies. Community delivery of the test enhanced the reputation and visibility of the CHVs as credible primary care providers. CHVs in turn were motivated and confident to deliver home pregnancy testing and did not find it as an unnecessary burden; instead, they perceived it as a complement to their work in providing ANC in the community. Challenges identified included test shortages, confidentiality and safeguarding risks, and difficulties accessing facility-based care post-referral. Newly identified pregnant adolescents hesitated to seek ANC due to stigma, fear of reprimand, unwanted parental notification, and perceived pressure from healthcare workers to keep the pregnancy. CONCLUSION: Home pregnancy testing by CHVs can improve early ANC initiation in resource-poor settings. Mitigating privacy, confidentiality, and safeguarding concerns is imperative. Additional support for women transitioning from pregnancy identification to ANC is essential to ensure appropriate care. Future research should focus on integrating home pregnancy testing into routine community health services.


Assuntos
Aceitação pelo Paciente de Cuidados de Saúde , Testes de Gravidez , Cuidado Pré-Natal , População Rural , Humanos , Feminino , Quênia , Gravidez , Adulto , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Adolescente , Adulto Jovem , Agentes Comunitários de Saúde , Pesquisa Qualitativa , Entrevistas como Assunto , Serviços de Assistência Domiciliar
5.
J Assist Reprod Genet ; 41(9): 2367-2377, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39026124

RESUMO

PURPOSE: Determine if the SPIKES method was associated with less distress and more compassion than current modes of delivering negative pregnancy test results to patients undergoing in vitro fertilization. METHODS: Twenty-seven nurses from two centers were randomized to use the modified SPIKES script or continue their standard of care; 136 patients with a negative hCG following embryo transfer were included. SPIKES nurses received 1 h of training by a study psychologist; nurses in the control group were instructed to deliver the news as done previously. Patients who underwent embryo transfer and received a call by a participating nurse with a negative test result received an email invitation on the following day. RESULTS: Control patients reported significantly less distress than SPIKES patients; 33% of SPIKES patients reported that they had felt "extremely sad," compared to 15.2% of the control patients (p = 0.01). Perceived compassion did not differ between the groups (all p ≥ 0.22). CONCLUSION: Patients who received a negative pregnancy test result from the nurses who received a brief training and a script on how to deliver bad news via the modified SPIKES protocol reported significantly more distress than patients receiving negative results from nurses utilizing their standard of care. It is unclear whether a modified SPIKES method to deliver negative pregnancy test results will benefit patients undergoing in vitro fertilization. TRIAL REGISTRATION: Clinical trials.gov NCT04917445.


Assuntos
Transferência Embrionária , Fertilização in vitro , Humanos , Feminino , Fertilização in vitro/métodos , Gravidez , Adulto , Transferência Embrionária/métodos , Projetos Piloto , Testes de Gravidez/métodos , Testes de Gravidez/psicologia , Empatia
6.
Mikrochim Acta ; 191(2): 114, 2024 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-38286853

RESUMO

The detection of botulinum neurotoxin A (BoNT/A) endopeptidase activity by pregnancy test paper based on human chorionic gonadotropin (hCG)-functionalized peptide-modified magnetic nanoparticles (MNs) is described for the first time. HCG-functionalized SNAP-25 peptide substrate with hydrolysis recognition sites was optimally designed. HCG can be recognized by pregnancy test strips. BoNT/A light chain (BoNT-LcA) is the central part of the endopeptidase function in holotoxin, which can specifically hydrolyze SNAP-25 peptide to release the hCG-peptide probe, and the hCG-peptide probe released can be quantitatively detected by pregnancy test strips, achieving indirect determination of BoNT/A. By quantifying the T-line color intensity of test strips, the visual detection limit for BoNT-LcA is 12.5 pg/mL, and the linear range of detection for BoNT-LcA and BoNT/A holotoxin was 100 pg/mL to 1 ng/mL and 25 to 250 ng/mL. The ability of the method to quantify BoNT/A was validated in human serum samples. This method shows the potential for sensitive detecting BoNT/A and has prospects for the diagnosis and prognosis of clinical botulism.


Assuntos
Toxinas Botulínicas Tipo A , Glicosídeos , Nanopartículas de Magnetita , Testes de Gravidez , Triterpenos , Humanos , Feminino , Gravidez , Endopeptidases , Gonadotropina Coriônica
7.
Sensors (Basel) ; 24(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38732847

RESUMO

The most reliable methods for pregnancy diagnosis in dairy herds include rectal palpation, ultrasound examination, and evaluation of plasma progesterone concentrations. However, these methods are expensive, labor-intensive, and invasive. Thus, there is a need to develop a practical, non-invasive, cost-effective method that can be implemented on the farm to detect pregnancy. This study suggests employing microwave dielectric spectroscopy (MDS, 0.5-40 GHz) as a method to evaluate reproduction events in dairy cows. The approach involves the integration of MDS data with information on milk solids to detect pregnancy and identify early embryonic loss in dairy cows. To test the ability to predict pregnancy according to these measurements, milk samples were collected from (i) pregnant and non-pregnant randomly selected cows, (ii) weekly from selected cows (n = 12) before insemination until a positive pregnancy test, and (iii) daily from selected cows (n = 10) prior to insemination until a positive pregnancy test. The results indicated that the dielectric strength of Δε and the relaxation time, τ, exhibited reduced variability in the case of a positive pregnancy diagnosis. Using principal component analysis (PCA), a clear distinction between pregnancy and nonpregnancy status was observed, with improved differentiation upon a higher sampling frequency. Additionally, a neural network machine learning technique was employed to develop a prediction algorithm with an accuracy of 73%. These findings demonstrate that MDS can be used to detect changes in milk upon pregnancy. The developed machine learning provides a broad classification that could be further enhanced with additional data.


Assuntos
Micro-Ondas , Leite , Animais , Feminino , Bovinos , Leite/química , Gravidez , Análise de Componente Principal , Espectroscopia Dielétrica/métodos , Indústria de Laticínios/métodos , Testes de Gravidez/métodos , Testes de Gravidez/veterinária , Algoritmos
8.
Anal Chem ; 95(37): 14111-14118, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37668549

RESUMO

With an increasing incidence worldwide, inflammatory bowel disease (IBD) is a chronic inflammatory disease affecting the gastrointestinal tract, which impairs the life quality of patients. Therefore, it is of great significance to construct a sensitive, simple, and convenient biosensor to analyze IBD-associated biomarkers for an auxiliary diagnosis of IBD. Intestinal alkaline phosphatase (IAP), expressed by the intestinal epithelium, is an endogenous protein that is thought to play a vital role in maintaining intestinal homeostasis and is considered a potential biomarker for IBD. Here, an IAP detection method was developed using pregnancy test strips by dephosphorylation. Initially, a double-stranded DNA (dsDNA) was designed to respond to IAP and acted as an activator of Cas12a. In the presence of IAP, the designed dsDNA was not digested by lambda exonuclease (λ exo), which hybridized to the Cas12a-crRNA duplex and resulted in the activation of the trans-cleavage of Cas12a. Further, the activated Cas12a cleaved the single-strand DNA (ssDNA) linker in the MBs-ssDNA-hCG probe, triggering the release of hCG. With magnetic separation, the released hCG could be quantitatively detected by pregnancy test strips. IAP levels were analyzed in feces from colitis and healthy mice by pregnancy test strips. The results showed that the IAP level of colitis mice (3.89 ± 1.92 U/L) was much lower than that of healthy mice (39.64 ± 24.93 U/L), indicating the correlation between IAP and intestinal inflammation. Taken together, a sensitive, user-friendly detection assay based on pregnancy test strips was constructed to monitor IAP and used as an auxiliary diagnostic approach for IBD in a clinical scene.


Assuntos
Colite , Doenças Inflamatórias Intestinais , Testes de Gravidez , Feminino , Gravidez , Animais , Camundongos , Fosfatase Alcalina , Sistemas CRISPR-Cas , Doenças Inflamatórias Intestinais/diagnóstico , DNA de Cadeia Simples , Inflamação/diagnóstico
9.
Analyst ; 148(11): 2573-2581, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37159023

RESUMO

The rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has promoted the development of nucleic acid diagnosis technology. Several platforms with isothermal amplification methods have achieved sensitive and specific detection of SARS-CoV-2. However, they still suffer from complicated operations, delicate instruments, and unintuitive signal output modes. Here, a system consisting of CRISPR Cas12a-based biosensors and commercial pregnancy test strips (CRISPR-PTS) was established for the point-of-care testing of SARS-CoV-2. The target viral nucleic acids were finally reflected on the test strips through four steps, namely sample pretreatment, RT-RAA amplification, CRISPR Cas12a reaction, and separation-free hCG detection. This CRISPR-PTS assay possessed an outstanding sensitivity of as low as 1 copy per µL for SARS-CoV-2 detection and showed an excellent specificity in distinguishing the SARS-CoV-2 pseudovirus as well as other SARS-like viral clinical samples. In addition, the CRISPR-PTS assay performed well in practical applications, with 96.3% agreement versus RT-qPCR in spiked samples. With the advantages of low reagent cost, simple operation procedure, and visible signal output, CRISPR-PTS assay was expected to provide a strong supplement in the prevention and early diagnosis of infectious diseases in resource-limited situations.


Assuntos
COVID-19 , Ácidos Nucleicos , Testes de Gravidez , Feminino , Gravidez , Humanos , COVID-19/diagnóstico , Sistemas CRISPR-Cas/genética , SARS-CoV-2/genética , Testes Imediatos , Técnicas de Amplificação de Ácido Nucleico , Sensibilidade e Especificidade , RNA Viral/genética
10.
J Oral Maxillofac Surg ; 81(2): 150-155, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36462536

RESUMO

PURPOSE: Human chorionic gonadotropin (hCG) testing is performed prior to surgical procedures to ensure patient and fetal safety. The purpose of this study was to evaluate the utility of routine pregnancy testing prior to elective outpatient oral and maxillofacial surgery procedures being performed with intravenous sedation (IVS). METHODS: A retrospective cohort study was implemented assessing hCG testing in postmenarche females who underwent elective outpatient oral surgery procedures scheduled with IVS at a tertiary care institution. Medical records were used to identify eligible subjects aged 12 to 45 years. The primary predictor variable was age, and the primary outcome variable was urine hCG test result. Age was divided into groups to reflect early adolescence (12 to 14 years), mid-adolescence (15 to 17 years), late adolescence/early adulthood (18 to 24 years) and adulthood (25+ years). Secondary outcome variables included inability to void for hCG testing, change in anesthetic, case cancellation or rescheduling and were measured over a 2 year period. Descriptive statistics were performed. Relative risk (RR) and Cochran-Armitage test for trend were calculated to determine the statistical significance of age on inability to void. RESULTS: The sample consisted of 5,006 females, with a median age (IQR, range) of 18.0 (3.6, 12.0 to 43.6) years. There was one positive urine hCG result providing a preoperative pregnancy rate of 0.02%. Fourteen of 1,195 subjects (1.2%) over a 2 year period were unable to provide a urine hCG sample. There was a statistically significant trend in inability to void as age groups got older (P = .001). Patients aged 12 to 17 years had an increased risk of being unable to void compared to patients 18 years and older (RR: 14.30, 95% CI: 1.88 to 108.99, P = .01). The total cost of testing over the 11 year observation period was $9,019.59. CONCLUSIONS: The risk of surgical cancellations and delayed care due to patients' inability to void preoperatively plus a lack of any positive preoperative urine hCG findings in patients under 18 years of age in this study, call into question the necessity of routine preoperative hCG screening in pediatric patients presenting for IVS for elective outpatient oral and maxillofacial procedures.


Assuntos
Testes de Gravidez , Cirurgia Bucal , Gravidez , Feminino , Adolescente , Humanos , Criança , Estudos Retrospectivos , Gonadotropina Coriônica/urina , Testes de Gravidez/métodos , Procedimentos Cirúrgicos Eletivos
11.
Arch Gynecol Obstet ; 308(2): 569-577, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37156908

RESUMO

PURPOSE: The purpose of this study was to identify if switching from intramuscular (IM) to vaginal progesterone compared to staying on IM progesterone after a positive pregnancy test following embryo transfer (ET) is associated with miscarriage risk. METHODS: A retrospective cohort study was performed in a private university-affiliated fertility clinic and included women aged 18-50 years with a positive pregnancy test following ET. The two groups studied were: women who stayed on IM progesterone following a positive pregnancy test and those who switched to vaginal progesterone after a positive test. The main outcome measured was risk of miscarriage < 24 weeks gestation as a proportion of non-biochemical pregnancies. RESULTS: 1988 women were included in the analysis. Among the baseline characteristics, the presence of prior miscarriages as well as prior failed ETs, and frozen cycles (vs fresh) as type of transfer were associated with IM progesterone use (p values ≤ 0.01). As per miscarriage risk < 24 weeks, 22.4% (274/1221) of patients in the IM progesterone group experienced a miscarriage compared with 20.7% (159/767) in the vaginal progesterone group (OR 0.90; 95% CI 0.73-1.13). A multivariable logistic regression model revealed an adjusted OR (aOR) of 0.97 (95% CI 0.77-1.22). CONCLUSION: This study suggests that switching from IM to vaginal progesterone after a positive pregnancy test following an ET is not associated with miscarriage risk. Considering that IM progesterone imposes substantial discomfort, this study offers reassurance and some flexibility in treatment protocols. Further prospective studies are necessary to corroborate the results of this study.


Assuntos
Aborto Espontâneo , Testes de Gravidez , Gravidez , Humanos , Feminino , Progesterona/efeitos adversos , Aborto Espontâneo/epidemiologia , Estudos Retrospectivos , Estudos Prospectivos , Fertilização in vitro , Transferência Embrionária , Suplementos Nutricionais , Taxa de Gravidez
12.
Aust N Z J Obstet Gynaecol ; 63(6): 797-802, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37452451

RESUMO

BACKGROUND: Follow-up after early medical abortion (EMA) in Australia often entails tracking serum human chorionic gonadotropin levels or performing ultrasonography in-clinic. In other countries, methods of follow-up such as using a low-sensitivity urine pregnancy test (LSUPT), telephone evaluation and a questionnaire have been demonstrated to be safe and acceptable. AIMS: To evaluate the safety and efficacy of telephone follow-up after EMA using an LSUPT and questionnaire. MATERIALS AND METHODS: A prospective observational cohort study of patients undergoing telephone follow-up after EMA using an LSUPT and questionnaire was conducted from March 26 to July 31, 2020. Outcomes of patients who returned to clinic because of a positive LSUPT were evaluated and adverse event rates were calculated. Routinely collected adverse event information was used to compare complication rates during the evaluation period with that prior to introduction of the LSUPT. RESULTS: During the study period, 2223 patients underwent the new protocol. One hundred and ninety-seven patients had a positive LSUPT at their telephone follow-up. One hundred and thirty-two had an incomplete abortion, 11 had a continuing pregnancy, 53 had a complete abortion and one left the clinic before full assessment. CONCLUSIONS: Introduction of telephone follow-up with an at-home LSUPT reduced the number of patients requiring unnecessary clinic appointments, with over 90% of patients completing their follow-up at home. Complication rates during the study period were found to be at least comparable with previously identified organisational adverse events.


Assuntos
Aborto Induzido , Aborto Espontâneo , Misoprostol , Testes de Gravidez , Feminino , Gravidez , Humanos , Seguimentos , Estudos Prospectivos , Aborto Induzido/efeitos adversos , Aborto Induzido/métodos , Testes de Gravidez/métodos , Telefone
13.
Anal Chem ; 94(47): 16384-16392, 2022 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-36377849

RESUMO

Matrix metalloproteinase (MMP) is closely correlated with tumorigenesis and progression. Establishing a low-cost, simple, rapid, and sensitive method for its detection is highly desired for the broad-spectrum screening of oral cancer. Herein, we combine the MMP-specific cleavage ability with magnetic separation technology and a commercial test strip to construct a sensitive biosensor to detect MMP-1 conveniently for the first time. The method involves two DNA probes, peptide-DNA1 and hCG-DNA2, where DNA1 and DNA2 are complementary sequences, and the peptide labeled with biotin can bind streptavidin-modified magnetic nanoparticles stably. The human chorionic gonadotropin (hCG) is the target of the pregnancy test strip. The cleavage reaction mediated by MMP-1 releases peptide-DNA1 and the hybridized hCG-DNA2 into the solution, and the hCG probe in the solution can develop color on the test strip for the determination of MMP-1 after magnetic separation. This method utilizes the high specificity of MMP-1's proteolytic cleavage and the high sensitivity of the test strip to the target probe, achieving a sensitive detection of MMP-1 with a visual detection limit of 65.5 pg/mL. The method shows better anti-interference and sensitivity than the enzyme-linked immunosorbent assay in the application of a biological sample matrix, suggesting its great potential for clinical diagnosis, especially for broad-spectrum oral cancer screening.


Assuntos
Técnicas Biossensoriais , Testes de Gravidez , Gravidez , Feminino , Humanos , Metaloproteinase 1 da Matriz , Saliva , Sondas de DNA , Técnicas Biossensoriais/métodos , Peptídeos , Limite de Detecção
14.
Curr Opin Obstet Gynecol ; 34(6): 379-385, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36165044

RESUMO

PURPOSE OF REVIEW: To assess the efficacy, benefits, and limitations of available and emerging follow-up options for medication abortion. RECENT FINDINGS: Medication abortion follow-up does not have to be a 'one size fits all' protocol. From most to least invasive, follow-up options include facility-based ultrasound, laboratory-based repeat serum beta-human chorionic gonadotropin (hCG) testing, urine hCG testing (high sensitivity, low sensitivity, and multilevel pregnancy tests), self-assessment with symptom evaluation, and no intervention. Provider or facility-dependent follow-up, including ultrasound and serum testing are effective, but have several limitations, including needing to return to a facility and cost. Remote, client-led follow-up options, such as urine pregnancy testing and symptoms evaluation, are well tolerated and effective for ruling out the rare outcome of ongoing pregnancy after medication abortion and have several advantages. Advantages include being inexpensive and flexible. However, it is important to note that low-sensitivity and multilevel pregnancy tests are not available in all settings. In studies evaluating client-led follow-up with urine pregnancy tests, ongoing pregnancies were identified over half the time with symptoms alone. SUMMARY: Guidelines from several professional organizations have aligned with the evidence and no longer recommend routine office-based follow-up. To ensure care is person-centered, providers should offer follow-up options that align with the comfort, logistical ability, and values of the client.


Assuntos
Aborto Induzido , Testes de Gravidez , Gravidez , Feminino , Humanos , Seguimentos , Aborto Induzido/métodos , Testes de Gravidez/métodos , Gonadotropina Coriônica
15.
Stud Fam Plann ; 53(1): 43-59, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34878176

RESUMO

The earlier a woman learns about her pregnancy status, the sooner she can make decisions about her own and infant's health. This paper examines how women learn about their pregnancy status and measures how access to pregnancy tests affects earlier pregnancy knowledge. Using 10 years of individual-level monthly panel data in Nepal, we find that, on average, women learn they are pregnant in their 4.6th month of pregnancy. Living approximately a mile further from a clinic offering pregnancy tests increases the time a woman knows she is pregnant by one week (5 percent increase) and decreases the likelihood of knowing in the first trimester by 4.5 percentage points (16 percent decrease). Women with prior pregnancies experience the most substantial effects of distance within the first two trimesters, while, for women experiencing their first pregnancy, distance does not affect knowledge. These results suggest that, while access to clinics can increase pregnancy awareness for women who recognize pregnancy symptoms, other complementary policies are needed to increase pregnancy awareness of women in their first pregnancy.


Assuntos
Gravidez , Feminino , Humanos , Nepal , Testes de Gravidez , Fatores de Tempo
16.
BMC Pregnancy Childbirth ; 22(1): 674, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050632

RESUMO

BACKGROUND: The majority of women living in rural Kenya access antenatal care (ANC) late in pregnancy, and approximately 20% have an unmet need for family planning (FP). This study aimed to determine whether training community health volunteers (CHVs) to deliver urine pregnancy testing (UPT), post-test counselling, and referral to care was an acceptable and feasible intervention to support timely initiation of ANC and uptake of FP. METHODS: We applied community-based participatory methods to design and implement the pilot intervention between July 2018 and May 2019. We conducted qualitative content analysis of 12 pre-intervention focus group discussions (FGDs) with women, men, and CHVs, and of 4 post-intervention FGDs with CHVs, each with 7-9 participants per FGD group. Using a pragmatic approach, we conducted inductive line-by-line coding to generate themes and subthemes describing factors that positively or negatively contributed to the intervention's acceptability and feasibility, in terms of participants' views and the intervention aims. RESULTS: We found that CHV-delivered point of care UPT, post-test counselling, and referral to care was an acceptable and feasible intervention to increase uptake of ANC, FP, and other reproductive healthcare services. Factors that contributed to acceptability were: (1) CHV-delivery made UPT more accessible; (2) UPT and counselling supported women and men to build knowledge and make informed choices, although not necessarily for women with unwanted pregnancies interested in abortion; (3) CHVs were generally trusted to provide counselling, and alternative counselling providers were available according to participant preference. A factor that enhanced the feasibility of CHV delivering UPT and counselling was CHV's access to appropriate supplies (e.g. carrying bags). However, factors that detracted from the feasibility of women actually accessing referral services after UPT and counselling included (1) downstream barriers like cost of travel, and (2) some male community members' negative attitudes toward FP. Finally, improved financial, educational, and professional supports for CHVs would be needed to make the intervention acceptable and feasible in the long-term. CONCLUSION: Training CHVs in rural western Kenya to deliver UPT, post-test counselling, and referral to care was acceptable and feasible to men, women, and CHVs in this context, and may promote early initiation of ANC and uptake of FP. Additional qualitative work is needed to explore implementation challenges, including issues related to unwanted pregnancies and abortion, the financial burden of volunteerism on CHVs, and educational and professional supports for CHVs.


Assuntos
Serviços de Saúde Comunitária , Testes de Gravidez , Serviços de Planejamento Familiar/métodos , Estudos de Viabilidade , Feminino , Humanos , Quênia , Masculino , Gravidez , Pesquisa Qualitativa
17.
Sensors (Basel) ; 22(17)2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36081100

RESUMO

The direct integration of paper-based microfluidic fuel cells (µFC's) toward creating autonomous lateral flow assays has attracted attention. Here, we show that an air-breathing paper-based µFC could be used as a power supply in pregnancy tests by oxidizing the human urine used for the diagnosis. We present an air-breathing paper-based µFC connected to a pregnancy test, and for the first time, as far as we know, it is powered by human urine without needing any external electrolyte. It uses TiO2-Ni as anode and Pt/C as cathode; the performance shows a maximum value of voltage and current and power densities of ∼0.96 V, 1.00 mA cm-2, and 0.23 mW cm-2, respectively. Furthermore, we present a simple design of a paper-based µFC's stack powered with urine that shows a maximum voltage and maximum current and power densities of ∼1.89 V, 2.77 mA cm-2 and 1.38 mW cm-2, respectively, which powers the display of a pregnancy test allowing to see the analysis results.


Assuntos
Microfluídica , Testes de Gravidez , Fontes de Energia Elétrica , Eletrodos , Feminino , Humanos , Oxirredução , Gravidez
18.
Angew Chem Int Ed Engl ; 61(12): e202115907, 2022 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-35064613

RESUMO

Desirable biosensing assays need to be sensitive, specific, cost-effective, instrument-free, and versatile. Herein we report a new strategy termed CLIPON (CRISPR and Large DNA assembly Induced Pregnancy strips for signal-ON detection) that can deliver these traits. CLIPON integrates a commercial pregnancy test strip (PTS) with four biological elements: the human chorionic gonadotropin (hCG), CRISPR-Cas12a, crRNA and cauliflower-like large-sized DNA assemblies (CLD). CLIPON uses the Cas12a/crRNA complex both to recognize a target of interest and to release CLD-bound hCG so that target presence can translate into a colorimetric signal on the PTS. We demonstrate the versatility of CLIPON through sensitive and specific detection of HPV genomic DNA, SARS-CoV-2 genomic RNA and adenosine. We also engineer a cell phone app and a hand-held microchip to achieve signal quantification. CLIPON represents an attractive option for biosensing and point-of-care diagnostics.


Assuntos
Sistemas CRISPR-Cas , Testes Imediatos , Testes de Gravidez , DNA/análise , Feminino , Humanos , Dispositivos Lab-On-A-Chip , Gravidez , RNA Viral/análise , Reprodutibilidade dos Testes , SARS-CoV-2/genética , Sensibilidade e Especificidade , Vírus/isolamento & purificação
19.
Anal Chem ; 93(35): 11956-11964, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34424659

RESUMO

Coronavirus diseases such as the coronavirus disease 2019 (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), pose serious threats. Portable and accurate nucleic acid detection is still an urgent need to achieve on-site virus screening and timely infection control. Herein, we have developed an on-site, semiautomatic detection system, aiming at simultaneously overcoming the shortcomings suffered by various commercially available assays, such as low accuracy, poor portability, instrument dependency, and labor intensity. Ultrasensitive isothermal amplification [i.e., reverse transcription loop-mediated isothermal amplification (RT-LAMP)] was applied to generate intensified SARS-CoV-2 RNA signals, which were then transduced to portable commercial pregnancy test strips (PTSs) via ultraspecific human chorionic gonadotropin (hCG)-conjugated toehold-mediated strand exchange (TMSE) probes (hCG-P). The entire detection was integrated into a four-channel, palm-size microfluidic device, named the microfluidic point-of-care (POC) diagnosis system based on the PTS (MPSP) detection system. It provides rapid, cost-effective, and sensitive detection, of which the lowest concentration of detection was 0.5 copy/µL of SARS-CoV-2 RNA, regardless of the presence of other similar viruses, even highly similar severe acute respiratory syndrome coronavirus (SARS-CoV). The successful detection of the authentic samples from different resources evaluated the practical application. The commercial PTS provides a colorimetric visible signal, which is instrument- and optimization-free. Therefore, this MPSP system can be immediately used for SARS-CoV-2 emergency detection, and it is worthy of further optimization to achieve full automation and detection for other infectious diseases.


Assuntos
COVID-19 , Testes de Gravidez , Feminino , Humanos , Dispositivos Lab-On-A-Chip , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Sistemas Automatizados de Assistência Junto ao Leito , Gravidez , RNA Viral/genética , SARS-CoV-2 , Sensibilidade e Especificidade
20.
Clin Chem ; 67(3): 508-517, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33257975

RESUMO

BACKGROUND: In the first trimester of pregnancy, the maternal platelet is directly involved in a positive feedback mechanism that facilitates invasion of the extravillous trophoblast into the maternal spiral arteries. Dysfunctional trophoblast invasion with defective deep placentation is primordial in the etiology of the "great obstetrical syndromes." METHODS: In this proof-of-concept study, using transcriptome analysis of circular RNA (circRNA) following RNA sequencing of maternal platelets, we tested whether pregnancy-specific circRNA markers could be identified in the first trimester of normal pregnancies. Differential transcript expression analysis of circRNAs, as predicted by Accurate CircRNA Finder Suite, CircRNA Identifier (version 2), and Known and Novel Isoform Explorer, was done using thromboSeq.R with variation of multiple settings. Test performance was checked for (a) de novo circRNA identification using the novel platelet-specific Plt-circR4 as a positive control, (b) complete segregation of groups (pregnant vs nonpregnant) after heat map-dendrogram clustering, (c) identification of pregnancy-specific circRNA markers at a false discovery rate (FDR) <0.05, and (d) confirmation of differentially expressed circRNA markers with an FDR <0.05 by an independent method, reverse transcription-quantitative PCR. RESULTS: Of the differentially expressed circRNAs with P values <0.05, 41 circRNAs were upregulated (logFC >2), and 52 circRNAs were downregulated (logFC less than -2) in first-trimester platelet RNA. Of these, nuclear receptor-interacting protein 1 circRNA covering exons 2 and 3 of the 5'-untranslated region was pregnancy specific with upregulation in first-trimester maternal platelets compared to nonpregnant controls. CONCLUSION: CircRNA sequencing of first-trimester maternal platelets permits the identification of novel pregnancy-specific RNA biomarkers. Future use could include the assessment of maternal and fetal well-being.


Assuntos
Plaquetas , Testes de Gravidez/métodos , Primeiro Trimestre da Gravidez/sangue , RNA Circular/genética , Análise de Sequência de RNA/métodos , Adulto , Biomarcadores/sangue , Feminino , Perfilação da Expressão Gênica/métodos , Humanos , Gravidez , Estudo de Prova de Conceito , RNA Circular/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA