Fixação de tubo orotraqueal: tecnologia diferenciada para segurança do paciente / Endotracheal tube fixing: differentiated technology / Fijación del tubo endotraqueal: la tecnología diferenciada
Lima, Danielly Mascarenhas de; Casteli, Christiane Pereira Martins; Brunori, Evelise Helena Fadini Reis; Ayoub, Andrea Cotait.
Afiliação
  • Lima, Danielly Mascarenhas de; Universidade de São Paulo. São Paulo (SP). BR
  • Casteli, Christiane Pereira Martins; Instituto Dante Pazzanese de Cardiologia. São Paulo (SP). BR
  • Brunori, Evelise Helena Fadini Reis; Instituto Dante Pazzanese de Cardiologia. São Paulo (SP). BR
  • Ayoub, Andrea Cotait; Instituto Dante Pazzanese de Cardiologia. São Paulo (SP). BR
Rev. enferm. UFPE on line ; 10(5): 1812-1821, maio 2016. ilus, graf
Article em En, Pt | BDENF | ID: biblio-1031668
Biblioteca responsável: BR9.1
RESUMO

Objetivo:

avaliar uma tecnologia diferenciada para fixação de tubo orotraqueal (TOT) e os critérios sobre segurança no manuseio e qualidade do artefato na perspectiva dos profissionais.

Método:

estudo retrospectivo descritivo, por meio da análise da ficha avaliação do produto preenchida por nove fisioterapeutas e doze enfermeiros em uma Unidade de Terapia Intensiva (UTI) adulta, no período de julho a setembro de 2012, de uma instituição hospitalar pública cardiológica de São Paulo/SP, Brasil. Para a análise dos dados foi utilizada a norma técnica NBR ISSO/IEC 14598-6.

Resultados:

com relação ao percentual de concordância dos profissionais a respeito dos critérios de avaliação, os resultados foram 100% sobre a facilidade na movimentação do tubo; 90% sobre a segurança do dispositivo, a facilidade na higiene oral e o conhecimento sobre produto semelhante; 85% sobre a facilidade no manuseio na aplicação; 71% sobre a qualidade do atendimento, a melhoria na aparência do paciente e adoção deste produto; 67% sobre a recomendação do produto; a duração média da fixação foi de seis dias.

Conclusão:

os profissionais avaliaram positivamente o artefato como tecnologia diferenciada para a fixação de TOT.(AU)
ABSTRACT

Objective:

to evaluate a differentiated technology to the endotracheal tube fixing (ET) and the criteria about the handling security and the artifact quality under the professional's perspective.

Methodology:

a descriptive and retrospective study, through the evaluation production form analysis filled by nine physiotherapists and twelve nurses in the adult Intensive Care Unit (ICU), between July and September 2012, from a cardiac public hospital institution in São Paulo/SP, Brazil. To the data analysis was used the technical norm NBR ISSO/IEC 14598-6.

Results:

regarding to the agreement percentage related to the evaluation criteria, the results were 100% about the tube movement facility; 90% about the dispositive security, the oral hygiene facility and the knowledge about a similar product; 85% about the handling application facility; 71% about the attendance quality, the patients' appearance improvement and this product adoption; 67% about the product recommendation; the medium length to the fixing was about 6 days.

Conclusion:

the professionals evaluated positively the artifact as differentiated technology to the ET fixation.(AU)
RESUMEN

Objetivo:

evaluar una tecnología diferenciada para la fijación del tubo endotraqueal (TET) y los criterios relativos a la seguridad en el manejo y la calidad del artefacto desde la perspectiva de los profesionales.

Metodología:

estudio retrospectivo descriptivo, a través del análisis de la evaluación del registro de lo producto completado por nueve fisioterapeutas y doce enfermeras en una Unidad de Cuidados Intensivos (UCI) de adultos en el periodo de julio a septiembre de 2012, en un hospital público cardiológico de Sao Paulo/SP, Brasil. Para análisis de datos se utilizó la norma técnica NBR ISSO/IEC 14598-6.

Resultados:

en relación con el porcentaje de acuerdo de los profesionales con respecto a los criterios de evaluación, los resultados fueron 100% de la instalación sobre el movimiento del tubo; 90% de la seguridad del dispositivo, la facilidad de la higiene oral y el conocimiento de un producto similar; 85% de la facilidad en el manejo de la aplicación; 71% de la calidad de la atención, mejorar la apariencia del paciente y la adopción de este producto; 67% de la recomendación del producto; la duración media de la fijación fue de seis días.

Conclusión:

profesionales evaluaron positivamente lo artefacto como tecnología diferenciada para fijación de ET.(AU)
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: BDENF Assunto principal: Tecnologia Biomédica / Segurança do Paciente / Pacientes Internados / Unidades de Terapia Intensiva / Intubação Intratraqueal Tipo de estudo: Guideline Limite: Adult / Female / Humans / Male Idioma: En / Pt Revista: Rev. enferm. UFPE on line Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: BDENF Assunto principal: Tecnologia Biomédica / Segurança do Paciente / Pacientes Internados / Unidades de Terapia Intensiva / Intubação Intratraqueal Tipo de estudo: Guideline Limite: Adult / Female / Humans / Male Idioma: En / Pt Revista: Rev. enferm. UFPE on line Ano de publicação: 2016 Tipo de documento: Article