Your browser doesn't support javascript.

BVS IEC

Instituto Evandro Chagas

Home > Pesquisa > ()
XML
Imprimir Exportar

Formato de exportação:

Exportar

Email
Adicionar mais destinatários
| |

Comparison of the indentation strength and single-edge-v-notched beam methods for dental ceramic fracture toughness testing

Domingues, Natália Bertolo; Galvão, Beatriz Regalado; Ribeiro, Sebastião; Almeida Junior, Antonio Alves de; Longhini, Diogo; Adabo, Gelson Luís.
Braz. j. oral sci ; 15(2): 109-112, Apr.-June 2016. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-848183

Aim:

To study influence of the cooling rate after sintering a veneering porcelain (Vita VM9) on fracture toughness by indentation strength (IS) and single-edge-v-notched beam (SEVNB) methods.

Methods:

Vita VM9 bars were sintered according to the manufacturer's recommendation and cooled under three conditions Slow (inside the furnace from sintering temperature to room temperature); Normal (inside the furnace from sintering temperature to 500 ºC and outside the furnace from 500 ºC to room temperature); and Fast (outside the furnace from sintering temperature to room temperature). Fracture toughness was measured by IS (n=10) and SEVNB (n=10) methods. Data were analyzed by two-way ANOVA (α=0.05).

Results:

The fracture toughness obtained from SEVNB (slow - 1.02±0.10; normal - 1.09±0.13; and fast - 1,02±0.18 MPa.m1/2 cooling techniques) was significantly lower than IS (slow - 1.19±0.13; normal - 1.17±0.07; and fast - 1.16±0.06 MPa. m1/2 cooling techniques). There was no significant influence of the cooling technique (p=0.012).

Conclusions:

The measurement technique influenced the fracture toughness values . IS method overestimated the fracture toughness values. Irrespective of the measuring method, cooling rate did not influence the Vita VM9 veneering porcelain fracture toughness (Au)