Your browser doesn't support javascript.
loading
Visibilizaçäo de obstruçöes em artérias coronárias pela ecocardiografia / Visualization of coronary artery stenoses by echocardiography
Gimenes, Vera Márcia L; Batlouni, Michel; Savioli Neto, Felício; Armaganijan, Dikran; Pontes Júnior, Sergio Cunha; Assef, Jorge Eduardo; Sousa, José Eduardo Moraes Rego de.
Afiliação
  • Gimenes, Vera Márcia L; s.af
  • Batlouni, Michel; s.af
  • Savioli Neto, Felício; s.af
  • Armaganijan, Dikran; s.af
  • Pontes Júnior, Sergio Cunha; s.af
  • Assef, Jorge Eduardo; s.af
  • Sousa, José Eduardo Moraes Rego de; s.af
Arq. bras. cardiol ; 54(4): 251-256, abr. 1990. tab
Article em Pt | LILACS | ID: lil-87217
Biblioteca responsável: BR1.1
RESUMO
Objetivo - Avaliar a sensibilidade e a especificidade da ecocardiografia bidimensional (Eco-2D) em identificar obstruções nos terços proximais e médios de artérias coronárias. Casuística e Métodos - Sessenta e cinco pacientes com coronariopatia aterosclerótica confirmada por cinecoronariografia, divididos em dois grupos Grupo I, 33 pacientes em que se conhecia previamente a localização e grau de obstrução das artérias coronárias; Grupo II, 32 pacientes cujo resultado da cinecoronariografia era desconhecido. Os resultados ecode obstrução, o Eco-2D superestimou a presença da em todos os casos. O Eco-2D foi realizado com o paciente em decúbito lateral esquerdo e o transdutor na posição paraesternal e o corte em eixo menor ao nível dos vasos da base.
ABSTRACT
Purpose - The purpose of this study was to determine the sensitivity and specificity of 2D ECO in identifying proximal and medial obstruction of the coronary artery. Patients and Method - Sixty five patients with coronary artery disease were studied. In thirty three patients with previous coronary angiography the echocardiographer had knowledge of the topography and the degree of the coronary obstruction (group I) but in thirty two patients he didn’t (group II). The mean age of group I was 54,4 years (44 to 76) and the mean age of the group II was 58 years (42 to 74). Two-dimensional echocardiography was performed at short-axis crosssectional of aortic valve and images were frozen at end-diastole and reject settings were used to best visualize the coronay artery.
Assuntos
Palavras-chave
Texto completo: 1 Base de dados: LILACS Assunto principal: Ultrassom / Doença da Artéria Coronariana / Cineangiografia / Ecocardiografia / Vasos Coronários Limite: Adult / Female / Humans / Male Idioma: Pt Revista: Arq. bras. cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 1990 Tipo de documento: Article
Texto completo: 1 Base de dados: LILACS Assunto principal: Ultrassom / Doença da Artéria Coronariana / Cineangiografia / Ecocardiografia / Vasos Coronários Limite: Adult / Female / Humans / Male Idioma: Pt Revista: Arq. bras. cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 1990 Tipo de documento: Article