Resorbable posterolateral graft containment in a rabbit spinal fusion model.
J Neurosurg
; 97(4 Suppl): 460-3, 2002 Nov.
Article
em En
| MEDLINE
| ID: mdl-12449201
ABSTRACT
OBJECT The authors studied the effect of a resorbable graft containment device in a rabbit posterolateral lumbar spinal fusion model. METHODS:
Twenty rabbits were divided into four groups autologous bone graft (ABG), ABG with the MacroPore containment device (ABG + MP), demineralized bone matrix (DBM), and DBM with the containment device (DBM + MP). Fusion mass was assessed at 6 weeks with high-resolution radiography and volumetric computerized tomography. The graft containment device was associated with alteration of the fusion mass structure and significant enhancement of fusion mass volume (ABG versus ABG + MP, p = 0.027; DBM versus DBM + MP, p = 0.043).CONCLUSIONS:
A bioabsorbable protective graft containment device successfully enhanced posterolateral spinal fusion mass volume.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Poliésteres
/
Fusão Vertebral
/
Traumatismos da Coluna Vertebral
/
Materiais Biocompatíveis
/
Implantes Absorvíveis
/
Vértebras Lombares
Tipo de estudo:
Prognostic_studies
Limite:
Animals
Idioma:
En
Revista:
J Neurosurg
Ano de publicação:
2002
Tipo de documento:
Article
País de afiliação:
Estados Unidos