Your browser doesn't support javascript.
loading
Short columns with molecularly imprinted monolithic stationary phases for rapid separation of diastereomers and enantiomers.
Huang, Xiaodong; Qin, Feng; Chen, Xiaoming; Liu, Yueqi; Zou, Hanfa.
Afiliação
  • Huang X; National Chromatographic Research & Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116011, China.
Article em En | MEDLINE | ID: mdl-15093154
ABSTRACT
Three molecularly imprinted monolithic columns with different length but almost identical column volume had been prepared. It was observed that the separation factors of diastereomers and enantiomers were almost unaffected by column length. However, the short column with dimension of 38 mm x 8 mm i.d. showed much lower resistance to flow rate so that it could be operated at much higher flow rates. By combining stepwise gradient elution with elevated flow rate, the diastereomers of cinchonine and cinchonidine and the enantiomers of Cbz-DL-Trp and Fmoc-DL-Trp were successfully separated within 3 min on the short column with dimension of 38 mm x 8 mm i.d. Based on the above results, a cinchonine imprinted monolithic disk with dimension of 10mm x 16 mm i.d. was further developed. The SEM image and the pore size distribution profile showed that large flow-through pores are present on the prepared monolith, which allowed mobile phase to flow through the disk with very low resistance. Chromatographic performances on the monolithic disk were almost unchanged compared with the long columns. A rapid separation of cinchonine and cinchonidine was achieved in 2.5 min at the flow rate of 9.0 ml/min. Furthermore, it was observed that there was almost no effect of the flow rate on the dynamic binding capacity at high flow rates. In addition, the effect of the loading concentration of analytes on the dynamic binding capacity, namely adsorption isotherm, was also investigated. A non-linear adsorption isotherm of cinchonine was observed on the molecularly imprinted monolith with cinchonine as template, which might be a main reason to result in the peak tailing of template molecule.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2004 Tipo de documento: Article País de afiliação: China
Buscar no Google
Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2004 Tipo de documento: Article País de afiliação: China