Your browser doesn't support javascript.
loading
Enumeration of antigen-specific CD8+ T lymphocytes by single-platform, HLA tetramer-based flow cytometry: a European multicenter evaluation.
Heijnen, Ingmar A F M; Barnett, David; Arroz, Maria J; Barry, Simon M; Bonneville, Marc; Brando, Bruno; D'hautcourt, Jean-Luc; Kern, Florian; Tötterman, Thomas H; Marijt, Erik W A; Bossy, David; Preijers, Frank W M B; Rothe, Gregor; Gratama, Jan W.
Afiliação
  • Heijnen IA; Division of Immunology, Department of Laboratory Medicine, Kantonsspital Aarau, Aarau, Switzerland. ingmar.heijnen@ksa.ch
Cytometry B Clin Cytom ; 62(1): 1-13, 2004 Nov.
Article em En | MEDLINE | ID: mdl-15468327
BACKGROUND: HLA class I peptide tetramers represent powerful diagnostic tools for detection and monitoring of antigen-specific CD8(+) T cells. The impetus for the current multicenter study is the critical need to standardize tetramer flow cytometry if it is to be implemented as a routine diagnostic assay. Hence, the European Working Group on Clinical Cell Analysis set out to develop and evaluate a single-platform tetramer-based method that used cytomegalovirus (CMV) as the antigenic model. METHODS: Absolute numbers of CMV-specific CD8(+) T cells were obtained by combining the percentage of tetramer-binding cells with the absolute CD8(+) T-cell count. Six send-outs of stabilized blood from healthy individuals or CMV-carrying donors with CMV-specific CD8(+) T-cell counts of 3 to 10 cells/microl were distributed to 7 to 16 clinical sites. These sites were requested to enumerate CD8(+) T cells and, in the case of CMV-positive donors, CMV-specific subsets on three separate occasions using the standard method. RESULTS: Between-site coefficients of variation of less than 10% (absolute CD8(+) T-cell counts) and approximately 30% (percentage and absolute numbers of CMV-specific CD8(+) T cells) were achieved. Within-site coefficients of variation were approximately 5% (absolute CD8(+) T-cell counts), approximately 9% (percentage CMV-specific CD8(+) T cells), and approximately 17% (absolute CMV-specific CD8(+) T-cell counts). The degree of variation tended to correlate inversely with the proportion of CMV-specific CD8(+) T-cell subsets. CONCLUSIONS: The single-platform MHC tetramer-based method for antigen-specific CD8(+) T-cell counting has been evaluated by a European group of laboratories and can be considered a reproducible assay for routine enumeration of antigen-specific CD8(+) T cells.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Antígenos de Histocompatibilidade Classe I / Contagem de Células / Linfócitos T CD8-Positivos / Citometria de Fluxo Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Cytometry B Clin Cytom Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Suíça
Buscar no Google
Base de dados: MEDLINE Assunto principal: Antígenos de Histocompatibilidade Classe I / Contagem de Células / Linfócitos T CD8-Positivos / Citometria de Fluxo Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Cytometry B Clin Cytom Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Suíça