The validity of chief complaint and discharge diagnosis in emergency department-based syndromic surveillance.
Fleischauer, Aaron T; Silk, Benjamin J; Schumacher, Mare; Komatsu, Ken; Santana, Sarah; Vaz, Victorio; Wolfe, Mitchell; Hutwagner, Lori; Cono, Joanne; Berkelman, Ruth; Treadwell, Tracee.
Afiliação
  • Fleischauer AT; Bioterrorism Preparedness and Response Program, National Center for Infectious Diseases, Centers for Disease Control and Prevention, 1600 Clifton Road, MS C-18, Atlanta, GA 30333, USA. alf6@cdc.gov
Acad Emerg Med ; 11(12): 1262-7, 2004 Dec.
Article em En | MEDLINE | ID: mdl-15576514
ABSTRACT

OBJECTIVE:

Emergency department (ED)-based syndromic surveillance systems are being used by public health departments to monitor for outbreaks of infectious diseases, including bioterrorism; however, few systems have been validated. The authors evaluated a "drop-in" syndromic surveillance system by comparing syndrome categorization in the ED with chief complaints and ED discharge diagnoses from medical record review.

METHODS:

A surveillance form was completed for each ED visit at 15 participating Arizona hospitals between October 27 and November 18, 2001. Each patient visit was assigned one of ten clinical syndromes or "none." For six of 15 EDs, kappa statistics were used to compare syndrome agreement between surveillance forms and syndrome categorization with chief complaint and ED discharge diagnosis from medical record review.

RESULTS:

Overall, agreement between surveillance forms and ED discharge diagnoses (kappa = 0.55; 95% confidence interval [CI] = 0.52 to 0.59) was significantly higher than between surveillance forms and chief complaints (kappa = 0.48; 95% CI = 0.44 to 0.52). Agreement between chief complaints and ED discharge diagnoses was poor for respiratory tract infection with fever (kappa = 0.33; 95% CI = 0.27 to 0.39). Furthermore, pediatric chief complaints showed lower agreement for respiratory tract infection with fever when compared with adults (kappa = 0.34 [95% CI = 0.20 to 0.47] vs. kappa = 0.44 [95% CI = 0.28 to 0.59], respectively).

CONCLUSIONS:

In general, this syndromic surveillance system classified patients into appropriate syndrome categories with fair to good agreement compared with chief complaints and discharge diagnoses. The present findings suggest that use of ED discharge diagnoses, in addition to or instead of chief complaints, may increase surveillance validity for both automated and drop-in syndromic surveillance systems.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Alta do Paciente / Vigilância da População / Doenças Transmissíveis / Serviço Hospitalar de Emergência Tipo de estudo: Diagnostic_studies / Evaluation_studies / Screening_studies Limite: Adult / Child / Humans País/Região como assunto: America do norte Idioma: En Revista: Acad Emerg Med Assunto da revista: MEDICINA DE EMERGENCIA Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Alta do Paciente / Vigilância da População / Doenças Transmissíveis / Serviço Hospitalar de Emergência Tipo de estudo: Diagnostic_studies / Evaluation_studies / Screening_studies Limite: Adult / Child / Humans País/Região como assunto: America do norte Idioma: En Revista: Acad Emerg Med Assunto da revista: MEDICINA DE EMERGENCIA Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Estados Unidos