Reoperation for composite graft infection after aortic root replacement.
Murayama, Hirokazu; Asano, Soichi; Yanai, Momoko; Yamamoto, Masaki; Tatsuno, Katsuhiko.
Afiliação
  • Murayama H; Department of Cardiovascular Surgery, Chiba Cardiovascular Center, Ichihara, Chiba, Japan.
Jpn J Thorac Cardiovasc Surg ; 53(9): 490-3, 2005 Sep.
Article em En | MEDLINE | ID: mdl-16200890
ABSTRACT
Composite graft infection after aortic root replacement is a serious complication and requires surgical reintervention with a high mortality rate. We report two cases of composite graft infection 3 months and 44 months after the primary operation. Each successfully underwent redo aortic root replacement with a new composite graft and a Freestyle stentless bioprosthesis, respectively. Both patients are currently well and without recurrence of infection 35 months and 48 months postoperatively.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Valva Aórtica / Infecções Relacionadas à Prótese / Implante de Prótese de Valva Cardíaca Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Male / Middle aged Idioma: En Revista: Jpn J Thorac Cardiovasc Surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Japão
Buscar no Google
Base de dados: MEDLINE Assunto principal: Valva Aórtica / Infecções Relacionadas à Prótese / Implante de Prótese de Valva Cardíaca Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Male / Middle aged Idioma: En Revista: Jpn J Thorac Cardiovasc Surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Japão