Your browser doesn't support javascript.
loading
Simultaneous measurement of serum testosterone and dihydrotestosterone by liquid chromatography-tandem mass spectrometry.
Shiraishi, Steve; Lee, Paul W N; Leung, Andrew; Goh, Victor H H; Swerdloff, Ronald S; Wang, Christina.
Afiliação
  • Shiraishi S; General Clinical Research Center, Division of Endocrinology and Metabolism, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, Torrance, CA 90509, USA.
Clin Chem ; 54(11): 1855-63, 2008 Nov.
Article em En | MEDLINE | ID: mdl-18801940
ABSTRACT

BACKGROUND:

Recent reports have described inherent problems with androgen immunoassays compared with mass spectrometry analyses.

METHODS:

We developed a method for measuring serum testosterone (T) and 5alpha-dihydrotestosterone (DHT) simultaneously via liquid-liquid extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with positive-mode electrospray ionization.

RESULTS:

The DHT and T calibrators showed a linear response from 0.069 nmol/L to 34.4 nmol/L and 69.3 nmol/L, respectively. T interference in the DHT assay and vice versa were negligible. Within- and between-run imprecision values were <5% for both analytes. Percent recoveries of T and DHT spiked into samples at concentrations spanning the calibration curve were 100%-113% and 98%-107%, respectively. The lower limit of quantification was 0.069 nmol/L for both steroids. Serum T concentrations measured by LC-MS/MS were different from those obtained by RIA, especially at lower T concentrations. Serum DHT concentrations measured by LC-MS/MS were markedly lower than those generated by RIA because of the nonselectivity of the RIA without chromatography. The reference intervals (mean +/- 2 SDs) determined for T and DHT were 9.2-33.7 nmol/L and 0.47-2.65 nmol/L, respectively, for 113 healthy adult men and 0.33-2.02 nmol/L and 0.09-0.91 nmol/L, respectively, for 133 healthy premenopausal women.

CONCLUSIONS:

We have developed and validated a selective and precise method for simultaneous measurements of serum T and DHT that can be adopted for routine measurements of these androgens in health and disease in men and women.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Di-Hidrotestosterona / Testosterona / Cromatografia Líquida / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Di-Hidrotestosterona / Testosterona / Cromatografia Líquida / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos