Evaluation of modified portable digital camera for screening of diabetic retinopathy.
Chalam, Kakarla V; Brar, Vikram S; Keshavamurthy, Ravi.
Afiliação
  • Chalam KV; Department of Ophthalmology, University of Florida-College of Medicine, Jacksonville, Fla., USA. kchalam@jax.ufl.edu
Ophthalmic Res ; 42(1): 60-2, 2009.
Article em En | MEDLINE | ID: mdl-19478543
ABSTRACT

AIMS:

To describe a portable wide-field noncontact digital camera for posterior segment photography.

METHODS:

The digital camera has a compound lens consisting of two optical elements (a 90-dpt and a 20-dpt lens) attached to a 7.2-megapixel camera. White-light-emitting diodes are used to illuminate the fundus and reduce source reflection. The camera settings are set to candlelight mode, the optic zoom standardized to x2.4 and the focus is manually set to 3.0 m.

RESULTS:

The new technique provides quality wide-angle digital images of the retina (60 degrees ) in patients with dilated pupils, at a fraction of the cost of established digital fundus photography.

CONCLUSIONS:

The modified digital camera is a useful alternative technique to acquire fundus images and provides a tool for screening posterior segment conditions, including diabetic retinopathy in a variety of clinical settings.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Retina / Fotografação / Seleção Visual / Retinopatia Diabética Tipo de estudo: Diagnostic_studies / Evaluation_studies / Screening_studies Limite: Humans Idioma: En Revista: Ophthalmic Res Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Retina / Fotografação / Seleção Visual / Retinopatia Diabética Tipo de estudo: Diagnostic_studies / Evaluation_studies / Screening_studies Limite: Humans Idioma: En Revista: Ophthalmic Res Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Estados Unidos