Solutions to remove a boundary image sticking in an ac plasma display panel.
Park, Choon-Sang; Tae, Heung-Sik.
Afiliação
  • Park CS; School of Electrical Engineering and Computer Science, Kyungpook National University, Daegu 702-701, South Korea.
Appl Opt ; 48(25): F76-81, 2009 Sep 01.
Article em En | MEDLINE | ID: mdl-19724318
ABSTRACT
When displaying a square-type image with peak luminance for approximately 500 h in a 42 in. plasma display panel TV with high Xe (15%) content, halo-type boundary image sticking was observed in the nondischarge region adjacent to the discharge region. The halo-type boundary image sticking phenomenon is due mainly to the redeposit of the Mg species on the MgO layer in the nondischarge region adjacent to the discharge region, which is verified by measuring the redeposited Mg species in the boundary image sticking region using a cross-sectional scanning electron microscope. Based on this result, three kinds of solution to remove the boundary image sticking of an ac plasma display panel are introduced. First, we completely recover the boundary image sticking cells by using a full-white aging process. Second, we prohibit the inherent production of boundary image sticking by sealing the plasma display panel under vacuum. The final solution is to prohibit the inherent production of boundary image sticking by use of lower gas pressure.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Appl Opt Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Coréia do Sul