Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases.
Krishnam, Mayil S; Tomasian, Anderanik; Malik, Sachin; Desphande, Vibhas; Laub, Gerhard; Ruehm, Stefan G.
Afiliação
  • Krishnam MS; Cardiovascular and Thoracic Imaging, UCI Medical Center, University of California, 333 City Boulevard West, Suite 1405, Irvine, CA 92868, USA. mayilkrishnam@gmail.com
Eur Radiol ; 20(6): 1311-20, 2010 Jun.
Article em En | MEDLINE | ID: mdl-20013276
ABSTRACT

OBJECTIVES:

The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases.

METHODS:

Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined.

RESULTS:

Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P < 0.001) with no significant difference for other aortic segments (P > 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01).

CONCLUSION:

Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aorta Torácica / Algoritmos / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Angiografia por Ressonância Magnética / Gadolínio DTPA / Doenças das Valvas Cardíacas Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aorta Torácica / Algoritmos / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Angiografia por Ressonância Magnética / Gadolínio DTPA / Doenças das Valvas Cardíacas Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos