Your browser doesn't support javascript.
loading
Influence of slice thickness on diagnoses of pulmonary nodules using low-dose CT: potential dependence of detection and diagnostic agreement on features and location of nodule.
Acad Radiol ; 18(5): 594-604, 2011 May.
Article em En | MEDLINE | ID: mdl-21377905
RATIONALE AND OBJECTIVES: The aims of this study were to assess the influence of slice thickness on the ability of radiologists to detect or not detect nodules and to agree or disagree on the diagnosis and also to investigate the potential dependence of these relations on the sizes, average computed tomographic (CT) values, and locations of the nodules. MATERIALS AND METHODS: Six radiologists performed qualitative diagnostic readings of multislice CT images with a slice thickness of 2 or 10 mm obtained from 360 subjects. The nodules were diagnosed as nodules for further examination (NFEs), inactive nodules for no further examination (INNFEs), or no abnormality. The results of the diagnoses were cross-tabulated and quantitatively analyzed using the average CT values, sizes, and locations of the nodules with reference to the 2-mm slices. Multivariate logistic regression analyses were used to estimate the significant associations of these parameters with the ability of radiologists to detect or not detect nodules and to agree or disagree on the diagnosis. RESULTS: Totals of 130 NFEs and 403 INNFEs for 2-mm slice thickness and 142 NFEs and 338 INNFEs for 10-mm slice thickness were diagnosed. Nodule classifications were as follows: the same diagnosis on both slice thickness images (67.6%), different diagnoses on two slice thickness images (21%), missed on 10-mm slice thickness images (10.6%), and misinterpreted on 10-mm slice thickness images (0.7%). Regarding detection and nondetection, NFE diagnoses were influenced by size (odds ratio [OR], 132.50; 95% confidence interval [CI], 4.77-4711) and the average CT value (OR, 27.20; 95% CI, 3.21-645.3), and INNFE diagnoses were influenced by size (OR, 16.10; 95% CI, 6.18-55.19) and the average CT value (OR, 7.67; 95% CI, 2.19-30.91). Regarding diagnostic agreement and disagreement, the NFE diagnoses were influenced by size (OR, 3.60; 95% CI, 1.29-11.04), nodule distance from the lung border (OR, 2.85; 95% CI, 1.27-6.65), and nodule location in the right upper lobe (OR, 0.07; 95% CI, 0.003-0.477), while the INNFE diagnoses were influenced by the average CT value (OR, 11.84; 95% CI, 3.33-55.86), size (OR, 0.42; 95% CI, 0.25-0.70), and nodule distance from the lung border (OR, 0.41; 95% CI, 0.25-0.66). CONCLUSIONS: The influence of slice thickness on the ability of radiologists to detect or not detect nodules and to agree or disagree on the diagnosis was quantitatively evaluated. Detection and nondetection of NFEs and INNFEs are influenced by size and average CT value. Agreement and disagreement on NFE and INNFE diagnoses are influenced not only by size and average CT value but also, importantly, by the locations of nodules.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Nódulos Pulmonares Múltiplos / Neoplasias Pulmonares Tipo de estudo: Diagnostic_studies / Observational_studies / Qualitative_research / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Acad Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Nódulos Pulmonares Múltiplos / Neoplasias Pulmonares Tipo de estudo: Diagnostic_studies / Observational_studies / Qualitative_research / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Acad Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Japão