Your browser doesn't support javascript.
loading
Clinical success rates for polyether crown impressions when mixed dynamically and statically.
Schmitter, Marc; Johnson, Glen H; Faggion, Clovis; Klose, Christina; Mitov, Gergo; Nothdurft, Frank P; Pospiech, Peter R; Rammelsberg, Peter; Ohlmann, Brigitte; Schwarz, Stefanie; Stober, Thomas; Schiller, Petra; Pritsch, Maria.
Afiliação
  • Schmitter M; Department of Prosthetic Dentistry, University Hospital Heidelberg, Heidelberg, Germany. marc_schmitter@med.uni-heidelberg.de
Clin Oral Investig ; 16(3): 951-60, 2012 Jun.
Article em En | MEDLINE | ID: mdl-21611728
ABSTRACT
The purpose of this study is to compare success rates of dual-viscosity impressions for two types of mixing techniques of the polyether elastomeric impression material. Additionally, influencing parameters on the success rates should be evaluated. The expectation was that there would be no difference between the success rates for the two mixing techniques. Two centres enrolled 290 subjects (727 teeth) into the trial. Patients were randomized for the two types of mixing techniques. One step, dual-viscosity impressions were made with either statically mixed Impregum Soft tray material (SAM) or dynamically mixed Impregum Penta H DuoSoft (DMM). Low viscosity Impregum Garant L DuoSoft was used for both groups. Gingival displacement involved the use of two braided cords. Full-arch trays were used exclusively. Both critical defects and operator errors were assessed for the first impression taken by trained dentists. The primary outcome was impression success. For comparison of the two mixing techniques, the odds ratio for success and the corresponding one-sided 95% confidence interval was calculated by a logistic regression model. To account for the dependence between several teeth within one patient, the method of general estimating equations was used. The overall impression success rate was 35.4%. Both mixing techniques showed equal success rates indicated by an OR of 1.0 and a lower limit of the one-sided 95% confidence interval of 0.71. Using this result to develop the corresponding interval for the difference, it could be shown that the success rate using SAM was at most 8.2% lower than that when using DMM with a probability of 95%. Multivariate logistic regression analysis of other potential influencing factors showed position of finish line (p = 0.008, supra compared to mixed), blood coagulation disorder (p = 0.021) and the level of training of the clinician (student vs dentist, p=0.008) to have an independent influence on the success rate. Dynamic mechanical mixing and the new static mixing of polyether tray material showed nearly equal success rates in the study even though success rates were comparatively low (DMM, 35.3%; SAM, 35.4%).
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnica de Moldagem Odontológica / Coroas / Materiais para Moldagem Odontológica Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Oral Investig Assunto da revista: ODONTOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnica de Moldagem Odontológica / Coroas / Materiais para Moldagem Odontológica Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Oral Investig Assunto da revista: ODONTOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Alemanha