Your browser doesn't support javascript.
loading
Thiocyanate and nitrite analysis using miniaturised isotachophoresis on a planar polymer chip.
Prest, Jeff E; Baldock, Sara J; Beardah, Matthew S; Doyle, Sean P; Fielden, Peter R; Goddard, Nicholas J; Treves Brown, Bernard J.
Afiliação
  • Prest JE; School of Chemical Engineering and Analytical Science, Manchester Interdisciplinary Biocentre, University of Manchester, Oxford Road, Manchester, UK M13 9PL. j.prest@manchester.ac.uk
Analyst ; 136(15): 3170-6, 2011 Aug 07.
Article em En | MEDLINE | ID: mdl-21674078
A new method has been developed to improve the determination of thiocyanate using isotachophoresis. This method uses complexation with copper(II) as a mechanism for improving the separation of thiocyanate from chlorate and perchlorate. By using a pH of 3.25 the method can also be used to analyse nitrite. Separations were carried out using a miniaturised poly(methyl methacrylate) (PMMA) separation device. Linearity was observed from 1.25 to 75 mg dm(-3) with a correlation coefficient of 0.998 for both thiocyanate and nitrite. Limits of detection for these two species were calculated to be 0.8 mg dm(-3) and 0.9 mg dm(-3) respectively. The method was successfully applied to the analysis of these anions in a range of samples including explosive residues.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2011 Tipo de documento: Article