Quantitative determination of odanacatib in human plasma using liquid-liquid extraction followed by liquid chromatography-tandem mass spectrometry analysis.
Sun, Li; Forni, Sabrina; Schwartz, Michael S; Breidinger, Sheila; Woolf, Eric J.
Afiliação
  • Sun L; DMPK, Merck Research Laboratories, West Point, PA 19486, USA. li_sun@merck.com
Article em En | MEDLINE | ID: mdl-22230741
ABSTRACT
Odanacatib (ODN, MK-0822) is an investigational drug under development for the treatment of osteoporosis. A quantitative LC/MS-MS methodology was developed and validated to determine ODN concentrations in human plasma, with a linear calibration range from 0.500 to 500ng/mL. Stable isotope (13)C(6)-labeled ODN was employed as the internal standard (IS). Sample preparation was based on liquid-liquid extraction of basified plasma with methyl t-butyl ether in a 96-well plate format. The extracted samples were analyzed on a liquid chromatography-tandem mass spectrometry system equipped with a turbo ion spray source. Chromatographic separation of the analyte and IS was achieved on a Phenomenex Luna C18 (50mm×2.0mm, 5µm) column. Ion pairs m/z 526→313 for the analyte and m/z 532→319 for the IS were monitored in positive ionization mode for MS detection. This methodology has been fully validated and proved to be rugged and reproducible. Intra- and inter-run variability was within 5.88%, with accuracy between 95.6 and 106% of the nominal concentrations. Analyte stability was evaluated under various sample preparation, analysis and storage conditions. This assay has been utilized to analyze human plasma samples obtained from phase I to III clinical trials.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos de Bifenilo / Cromatografia Líquida / Espectrometria de Massas em Tandem / Extração Líquido-Líquido Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos de Bifenilo / Cromatografia Líquida / Espectrometria de Massas em Tandem / Extração Líquido-Líquido Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Estados Unidos