Your browser doesn't support javascript.
loading
Fluorescence holography with improved signal-to-noise ratio by near image plane recording.
Lai, Xiaomin; Zhao, Yuan; Lv, Xiaohua; Zhou, Zhenqiao; Zeng, Shaoqun.
Afiliação
  • Lai X; Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, China.
Opt Lett ; 37(13): 2445-7, 2012 Jul 01.
Article em En | MEDLINE | ID: mdl-22743416
ABSTRACT
Holographic fluorescence imaging is very promising, as it can obtain three-dimensional fluorescence imaging without scanning. However, the current method usually records holograms far from the image plane, with the fluorescence decaying when spreading broadly. Here we show that the signal-to-noise ratio (SNR) of fluorescence holography can be improved by recording the high-contrast interferogram near the image plane. We found that this can be achieved by setting the focal length of the lens for the reference wave (f(2)) close to that for the object wave (f(1)). With experiments, we demonstrate an example of an increase of about 21 times in SNR by changing f(2) from infinity to 226 mm, which is close to f(1) (323 mm).
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Holografia / Razão Sinal-Ruído Idioma: En Revista: Opt Lett Ano de publicação: 2012 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Holografia / Razão Sinal-Ruído Idioma: En Revista: Opt Lett Ano de publicação: 2012 Tipo de documento: Article País de afiliação: China