Your browser doesn't support javascript.
loading
Percutaneous atrial septal defect closure in infants and toddlers: predictors of success.
Petit, Christopher J; Justino, Henri; Pignatelli, Ricardo H; Crystal, Matthew A; Payne, William A; Ing, Frank F.
Afiliação
  • Petit CJ; Lillie Frank Abercrombie Section of Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX 77030, USA. cp31971@yahoo.com
Pediatr Cardiol ; 34(2): 220-5, 2013 Feb.
Article em En | MEDLINE | ID: mdl-22806712
ABSTRACT
Device closure of atrial septal defect (ASD) is commonly performed in older children and adults. Infants and toddlers (age <4 years) are seldom referred for ASD closure due to size constraints. However, in many cases device ASD closure can be performed in this population. Between 2002 and 2012, 61 infants and toddlers were taken to the catheterization laboratory at our institution for ASD closure. Precatheterization transthoracic echocardiograms, intracatheterization transesophageal echocardiograms, and catheterization reports were reviewed. Fifty-three infants and toddlers presented for percutaneous ASD occlusion. Forty-eight (79 %) underwent successful closure, and 13 were referred for surgery without device attempt (n = 8) or after unsuccessful device occlusion (n = 4). Median age and weight at time of ASD closure were 2.99 years (range 0.3-3.8) and 11.7 kg (range 3.7-16.5). The device-to-septal length ratio was 0.81 (range 0.44-1.03). The 12 unsuccessful cases occurred in patients with larger defects (ASD diameter 17.5 ± 6.1 vs. 12.1 ± 4.2, p < 0.01). Deficient rims (absent or ≤ 4 mm) were seen in 9 of 12 (75 %) unsuccessful cases and in 19 of 41 (46 %) successful cases (p = 0.12). Multivariate analysis showed that patient size and ASD size were not independently associated with procedural success but that ASD size-to-patient weight ratio <1.2 (hazard ratio 9.5 [range1.7-17]) was associated with successful ASD closure. ASD device occlusion can be safely achieved in small children. An ASD size-to-patient weight ratio >1.2, not absolute patient weight or age, is associated with failure of the percutaneous approach. The midterm outcomes in these young patients are excellent.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Cardíaco / Dispositivo para Oclusão Septal / Comunicação Interatrial / Procedimentos Cirúrgicos Cardíacos Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Infant Idioma: En Revista: Pediatr Cardiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Cardíaco / Dispositivo para Oclusão Septal / Comunicação Interatrial / Procedimentos Cirúrgicos Cardíacos Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Infant Idioma: En Revista: Pediatr Cardiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos