Your browser doesn't support javascript.
loading
The cobas p 630 instrument: a dedicated pre-analytic solution to optimize COBAS® AmpliPrep/COBAS® TaqMan® system workflow and turn-around-time.
Vallefuoco, L; Sorrentino, R; Spalletti Cernia, D; Colucci, G; Portella, G.
Afiliação
  • Vallefuoco L; Dipartimento di Biologia e Patologia Cellulare e Molecolare, Università Federico II, Napoli, Italy.
J Virol Methods ; 186(1-2): 86-8, 2012 Dec.
Article em En | MEDLINE | ID: mdl-22827959
ABSTRACT
The cobas p 630, a fully automated pre-analytical instrument for primary tube handling recently introduced to complete the Cobas(®) TaqMan systems portfolio, was evaluated in conjunction with the COBAS(®) AmpliPrep/COBAS(®) TaqMan HBV Test, v2.0, COBAS(®) AmpliPrep/COBAS(®) TaqMan HCV Test, v1.0 and COBAS(®) AmpliPrep/COBAS(®) TaqMan HIV Test, v2.0. The instrument performance in transferring samples from primary to secondary tubes, its impact in improving COBAS(®) AmpliPrep/COBAS(®) TaqMan workflow and hands-on reduction and the risk of possible cross-contamination were assessed. Samples from 42 HBsAg positive, 42 HCV and 42 HIV antibody (Ab) positive patients as well as 21 healthy blood donors were processed with or without automated primary tubes. HIV, HCV and HBsAg positive samples showed a correlation index of 0.999, 0.987 and of 0.994, respectively. To assess for cross-contamination, high titer HBV DNA positive samples, HCV RNA and HIV RNA positive samples were distributed in the cobas p 630 in alternate tube positions, adjacent to negative control samples within the same rack. None of the healthy donor samples showed any reactivity. Based on these results, the cobas p 630 can improve workflow and sample tracing in laboratories performing molecular tests, and reduce turnaround time, errors, and risks.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Manejo de Espécimes / Técnicas de Diagnóstico Molecular / Automação Laboratorial Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Virol Methods Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Manejo de Espécimes / Técnicas de Diagnóstico Molecular / Automação Laboratorial Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Virol Methods Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Itália