Your browser doesn't support javascript.
loading
Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty).
Wong, Melissa H Y; Chew, Annabel; Htoon, Hla M; Lee, Beng H; Cheng, Jun; Liu, Jiang; Tan, Donald T; Mehta, Jodhbir S.
Afiliação
  • Wong MH; Singapore National Eye Centre (SNEC), 11 Third Hospital Avenue, 168751, SNEC, Singapore.
BMC Med Imaging ; 12: 25, 2012 Aug 01.
Article em En | MEDLINE | ID: mdl-22853647
ABSTRACT

BACKGROUND:

The CorneaL GrAft Thickness Evaluation (COLGATE) system was recently developed to facilitate the evaluation of corneal graft thickness from OCT images. Graft thickness measurement can be a surrogate indicator for detecting graft failure or success. The purpose of this study was to determine the reproducibility of the COLGATE system in measuring DSAEK graft area between two observers.

METHODS:

This was a prospective case series in which 50 anterior segment OCT images of patients who had undergone DSAEK in either eye were analysed. Two observers (MW, AC) independently obtained the image analysis for the graft area using both semi automated and automated method. One week later, each observer repeated the analysis for the same set of images. Bland-Altman analysis was performed to analyze inter and intra observer agreement.

RESULTS:

There was strong intraobserver correlation between the 2 semi automated readings obtained by both observers. (r = 0.936 and r = 0.962). Intraobserver ICC for observer 1 was 0.936 (95% CI 0.890 to 0.963) and 0.967 (95% CI 0.942 to 0.981) for observer 2. Likewise, there was also strong interobserver correlation (r = 0.913 and r = 0.969). The interobserver ICC for the first measurements was 0.911 (95% CI 0.849 to 0.949) and 0.968 (95% CI 0.945 to 0.982) for the second. There was statistical difference between the automatic and the semi automated readings for both observers (p = 0.006, p = 0.003). The automatic readings gave consistently higher values than the semi automated readings especially in thin grafts.

CONCLUSION:

The analysis from the COLGATE programme can be reproducible between different observers. Care must be taken when interpreting the automated analysis as they tend to over estimate measurements.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oftalmoscopia / Transplante de Córnea / Córnea / Tomografia de Coerência Óptica / Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Med Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Singapura

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oftalmoscopia / Transplante de Córnea / Córnea / Tomografia de Coerência Óptica / Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Med Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Singapura