Implantable cardioverter-defibrillators have reduced the incidence of resuscitation for out-of-hospital cardiac arrest caused by lethal arrhythmias.
Hulleman, Michiel; Berdowski, Jocelyn; de Groot, Joris R; van Dessel, Pascal F H M; Borleffs, C Jan Willem; Blom, Marieke T; Bardai, Abdenasser; de Cock, Carel C; Tan, Hanno L; Tijssen, Jan G P; Koster, Rudolph W.
Afiliação
  • Hulleman M; Department of Cardiology, Room G4-229, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, Netherlands.
Circulation ; 126(7): 815-21, 2012 Aug 14.
Article em En | MEDLINE | ID: mdl-22869841
BACKGROUND: Over the last decades, a gradual decrease in ventricular fibrillation (VF) as initial recorded rhythm during resuscitation for out-of-hospital cardiac arrest (OHCA) has been noted. We sought to establish the contribution of implantable cardioverter-defibrillator (ICD) therapy to this decline. METHODS AND RESULTS: Using a prospective database of all OHCA resuscitation in the province North Holland in the Netherlands (Amsterdam Resuscitation Studies [ARREST]), we collected data on all patients in whom resuscitation for OHCA was attempted in 2005-2008. VF OHCA incidence (per 100 000 inhabitants per year) was compared with VF OHCA incidence data during 1995-1997, collected in a similar way. We also collected ICD interrogations of all ICD patients from North Holland and identified all appropriate ICD shocks in 2005-2008; we calculated the number of prevented VF OHCA episodes, considering that only part of the appropriate shocks would result in avoided resuscitation. VF OHCA incidence decreased from 21.1/100 000 in 1995-1997 to 17.4/100 000 in 2005-2008 (P<0.001). Non-VF OHCA increased from 12.2/100 000 to 19.4/100 000 (P<0.001). VF as presenting rhythm declined from 63% to 47%. In 2005-2008, 1972 ICD patients received 977 shocks. Of these shocks, 339 were caused by a life-threatening arrhythmia. We estimate that these 339 shocks have prevented 81 (minimum, 39; maximum, 152) cases of VF OHCA, corresponding with 33% (minimum, 16%; maximum, 63%) of the observed decline in VF OHCA incidence. CONCLUSIONS: The incidence of VF OHCA decreased over the last 10 years in North Holland. ICD therapy explained a decrease of 1.2/100 000 inhabitants per year, corresponding with 33% of the observed decline in VF OHCA.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Ressuscitação / Desfibriladores Implantáveis / Parada Cardíaca Extra-Hospitalar Tipo de estudo: Incidence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Circulation Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Ressuscitação / Desfibriladores Implantáveis / Parada Cardíaca Extra-Hospitalar Tipo de estudo: Incidence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Circulation Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Holanda