The effects of spectral shape on two photon fluorescence excitation are investigated experimentally using an acousto-optic pulse shaper to modify femtosecond pulses from a Tisapphire laser. By using different spectral window shapes, we find that the measured two photon efficiency can vary by a factor of 2 for differently shaped spectra with the same full width at half maximum. We find that these effects are described well by a simple model assuming transform-limited pulses. The fact that even small changes in the spectral wings can significantly affect the efficiency of nonlinear processes has implications for biological multiphoton imaging, where it may be desirable to minimize sample exposure to radiation and maximize fluorescence or harmonic efficiency. © 1999 Society of Photo-Optical Instrumentation Engineers.