Your browser doesn't support javascript.
loading
The effect of statin use on embolic potential during carotid angioplasty and stenting.
Tadros, Rami O; Vouyouka, Ageliki G; Chung, Christine; Malik, Rajesh K; Krishnan, Prakash; Ellozy, Sharif H; Marin, Michael L; Faries, Peter L.
Afiliação
  • Tadros RO; Department of Vascular Surgery, Mount Sinai School of Medicine, New York, NY 10029, USA.
Ann Vasc Surg ; 27(1): 96-103, 2013 Jan.
Article em En | MEDLINE | ID: mdl-23088806
BACKGROUND: Statin use results in atherosclerotic plaque stabilization. We sought to determine the effects of statins on the size and number of embolic particles generated during carotid artery stenting (CAS). METHODS: Embolic debris from carotid filters following CAS was analyzed using photomicroscopy and imaging software. Patient comorbidities, pre-operative cerebrovascular symptoms, statin use, and outcomes (peri-operative major adverse events, MAE) were reviewed. RESULTS: Carotid filters from 62 consecutive CAS procedures were examined. The mean age is 68.7 ± 9.8 years, 64% were men, 41 (66%) were on statins at the time of CAS, and 27 (43.5%) had neurological symptoms pre-procedurally. The mean intra-procedural stenosis was similar between groups (statin: 89.4 ± 7.4% vs. no statin: 88.4 ± 5.9%, P = NS). There was no significant difference in overall pre-operative symptoms between the two groups. Statin users were more likely to have coronary artery disease (CAD, P = 0.02), hyperlipidemia (HL, P = 0.047), or have undergone coronary artery bypass (CABG, P = 0.01). Statin use was associated with significantly less embolic particles (statin: 16.4 ± 2.1 vs. no statin: 42.4 ± 9.5, P = 0.001) during CAS. Further, multivariate analysis controlling for CAD, HL, and CABG confirmed that statin use was independently associated with less captured debris (P = 0.005). There was no significant difference in the mean particle size (statin: 326.2 µm ± 31.1 vs. no statin 310.5 µm ± 41.8), peri-procedural stroke, and MAE between the two groups (P = NS). CONCLUSIONS: Statin use is associated with less embolic debris during CAS. Further investigation utilizing a larger study group is necessary to assess the impact of statin use on peri-procedural outcomes.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças das Artérias Carótidas / Stents / Angioplastia com Balão / Inibidores de Hidroximetilglutaril-CoA Redutases / Embolia / Dispositivos de Proteção Embólica Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Vasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças das Artérias Carótidas / Stents / Angioplastia com Balão / Inibidores de Hidroximetilglutaril-CoA Redutases / Embolia / Dispositivos de Proteção Embólica Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Vasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos