Your browser doesn't support javascript.
loading
An extended period of functional appliance therapy: a controlled clinical trial comparing the Twin Block and Dynamax appliances.
Lee, Robert T; Barnes, Emma; DiBiase, Andrew; Govender, Ravichandram; Qureshi, Usman.
Afiliação
  • Lee RT; *Department of Orthodontics, Bart's & The London NHS Trust, London, r.t.lee@qmul.ac.uk.
  • Barnes E; *Department of Orthodontics, Bart's & The London NHS Trust, London.
  • DiBiase A; **East Kent Hospitals University NHS Foundation Trust.
  • Govender R; *Department of Orthodontics, Bart's & The London NHS Trust, London.
  • Qureshi U; ***Department of Orthodontics, Q.M.U.L., London, UK.
Eur J Orthod ; 36(5): 512-21, 2014 Oct.
Article em En | MEDLINE | ID: mdl-23291502
The aim of this clinical trial was to compare the hard- and soft-tissue effects of 15 month full-time functional appliance therapy with Twin Block (TB) and Dynamax (Dx) appliances. The effects on both hard and soft tissue were analysed using cephalograms and three-dimensional optical surface laser scans. One hundred and three subjects with a class II division 1 malocclusion, and a minimum overjet of 7mm were available for analysis following stratified randomization according to gender and age. Data was collected at the start of treatment, 15 month therapy, and after 3 month post-treatment observation. Statistical analysis was conducted using analysis of covariance. The results demonstrated both appliances corrected the overjet with significantly increased skeletal dimensional changes with the TB compared with the Dx with forward movement of pogonion of 5.2mm (TB) and 0.7mm (Dx) P = 0.003. In addition, significant changes occurred particularly in the vertical dimension where there was also an increase in total anterior face height in both groups (TB = 6.4mm, Dx = 5.5mm) and significant (P = 0.003) mandibular length changes were also observed (TB = 7.2mm, Dx = 3.8mm). The cephalometric soft-tissue changes were significantly different between the two appliances at soft-tissue pogonion (TB = 9.8mm, Dx = 4.6mm, P = 0.001). Laser scan three-dimansional changes showed significant difference in the lower labial sulcus region where forward movements were observed (TB = 8.2mm, Dx = 6.2mm; P = 0.04). Overall these changes appear to be greater and more stable than those achieved in a previous 9 month study.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Desenho de Aparelho Ortodôntico / Aparelhos Ortodônticos Funcionais / Má Oclusão Classe II de Angle Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Adolescent / Child / Female / Humans / Male Idioma: En Revista: Eur J Orthod Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Desenho de Aparelho Ortodôntico / Aparelhos Ortodônticos Funcionais / Má Oclusão Classe II de Angle Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Adolescent / Child / Female / Humans / Male Idioma: En Revista: Eur J Orthod Ano de publicação: 2014 Tipo de documento: Article