ABSTRACT

BACKGROUND:

The multicenter PROTECT AF study (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) was conducted to determine whether percutaneous left atrial appendage closure with a filter device (Watchman) was noninferior to warfarin for stroke prevention in atrial fibrillation. METHODS AND

RESULTS:

Patients (n=707) with nonvalvular atrial fibrillation and at least 1 risk factor (age >75 years, hypertension, heart failure, diabetes, or prior stroke/transient ischemic attack) were randomized to either the Watchman device (n=463) or continued warfarin (n=244) in a 21 ratio. After device implantation, warfarin was continued for ≈45 days, followed by clopidogrel for 4.5 months and lifelong aspirin. Study discontinuation rates were 15.3% (71/463) and 22.5% (55/244) for the Watchman and warfarin groups, respectively. The time in therapeutic range for the warfarin group was 66%. The composite primary efficacy end point included stroke, systemic embolism, and cardiovascular death, and the primary analysis was by intention to treat. After 1588 patient-years of follow-up (mean 2.3±1.1 years), the primary efficacy event rates were 3.0% and 4.3% (percent per 100 patient-years) in the Watchman and warfarin groups, respectively (relative risk, 0.71; 95% confidence interval, 0.44%-1.30% per year), which met the criteria for noninferiority (probability of noninferiority >0.999). There were more primary safety events in the Watchman group (5.5% per year; 95% confidence interval, 4.2%-7.1% per year) than in the control group (3.6% per year; 95% confidence interval, 2.2%-5.3% per year; relative risk, 1.53; 95% confidence interval, 0.95-2.70).

CONCLUSIONS:

The "local" strategy of left atrial appendage closure is noninferior to "systemic" anticoagulation with warfarin. PROTECT AF has, for the first time, implicated the left atrial appendage in the pathogenesis of stroke in atrial fibrillation. CLINICAL TRIAL REGISTRATION URL http//www.clinicaltrials.gov. Unique identifier NCT00129545.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Fibrilação Atrial / Apêndice Atrial / Acidente Vascular Cerebral Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Circulation Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Fibrilação Atrial / Apêndice Atrial / Acidente Vascular Cerebral Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Circulation Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos