Your browser doesn't support javascript.
loading
Complications associated with endobronchial ultrasound-guided transbronchial needle aspiration: a nationwide survey by the Japan Society for Respiratory Endoscopy.
Asano, Fumihiro; Aoe, Motoi; Ohsaki, Yoshinobu; Okada, Yoshinori; Sasada, Shinji; Sato, Shigeki; Suzuki, Eiichi; Semba, Hiroshi; Fukuoka, Kazuya; Fujino, Shozo; Ohmori, Kazumitsu.
Afiliação
  • Asano F; Safety Management Committee, Japan Society for Respiratory Endoscopy, Tokyo, Japan. asano-fm@ceres.ocn.ne.jp
Respir Res ; 14: 50, 2013 May 10.
Article em En | MEDLINE | ID: mdl-23663438
BACKGROUND: With the recent widespread use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), there have been occasional reports on complications associated with its use. Previous reviews on EBUS-TBNA have been limited to studies by skilled operators, thus the results may not always be applicable to recent clinical practice. To assess the safety of EBUS-TBNA for the staging and diagnosis of lung cancer in Japan, a nationwide survey on its current usage status and complications associated with its use was conducted by the Japan Society for Respiratory Endoscopy (JSRE). METHODS: A questionnaire about EBUS-TBNA performed between January 2011 and June 2012 was mailed to 520 JSRE-accredited facilities. RESULTS: Responses were obtained from 455 facilities (87.5%). During the study period, EBUS-TBNA was performed in 7,345 cases in 210 facilities (46.2%) using a convex probe ultrasound bronchoscope, for 6,836 mediastinal and hilar lesions and 275 lung parenchymal lesions. Ninety complications occurred in 32 facilities. The complication rate was 1.23% (95% confidence interval, 0.97%-1.48%), with hemorrhage being the most frequent complication (50 cases, 0.68%). Infectious complications developed in 14 cases (0.19%) (Mediastinitis, 7; pneumonia, 4; pericarditis, 1; cyst infection, 1; and sepsis, 1). Pneumothorax developed in 2 cases (0.03%), one of which required tube drainage. Regarding the outcome of the cases with complications, prolonged hospitalization was observed in 14 cases, life-threatening conditions in 4, and death in 1 (severe cerebral infarction) (mortality rate, 0.01%). Breakage of the ultrasound bronchoscope occurred in 98 cases (1.33%) in 67 facilities (31.9%), and that of the puncture needle in 15 cases (0.20%) in 8 facilities (3.8%). CONCLUSIONS: Although the complication rate associated with EBUS-TBNA was found to be low, severe complications, including infectious complications, were observed, and the incidence of device breakage was high. Since the use of EBUS-TBNA is rapidly expanding in Japan, an educational program for its safe performance should be immediately established.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pneumotórax / Complicações Pós-Operatórias / Infecção da Ferida Cirúrgica / Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico / Hemorragia / Neoplasias Pulmonares Tipo de estudo: Clinical_trials / Etiology_studies / Incidence_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Respir Res Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pneumotórax / Complicações Pós-Operatórias / Infecção da Ferida Cirúrgica / Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico / Hemorragia / Neoplasias Pulmonares Tipo de estudo: Clinical_trials / Etiology_studies / Incidence_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Respir Res Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Japão