Complications associated with endobronchial ultrasound-guided transbronchial needle aspiration: a nationwide survey by the Japan Society for Respiratory Endoscopy.
Respir Res
; 14: 50, 2013 May 10.
Article
em En
| MEDLINE
| ID: mdl-23663438
BACKGROUND: With the recent widespread use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), there have been occasional reports on complications associated with its use. Previous reviews on EBUS-TBNA have been limited to studies by skilled operators, thus the results may not always be applicable to recent clinical practice. To assess the safety of EBUS-TBNA for the staging and diagnosis of lung cancer in Japan, a nationwide survey on its current usage status and complications associated with its use was conducted by the Japan Society for Respiratory Endoscopy (JSRE). METHODS: A questionnaire about EBUS-TBNA performed between January 2011 and June 2012 was mailed to 520 JSRE-accredited facilities. RESULTS: Responses were obtained from 455 facilities (87.5%). During the study period, EBUS-TBNA was performed in 7,345 cases in 210 facilities (46.2%) using a convex probe ultrasound bronchoscope, for 6,836 mediastinal and hilar lesions and 275 lung parenchymal lesions. Ninety complications occurred in 32 facilities. The complication rate was 1.23% (95% confidence interval, 0.97%-1.48%), with hemorrhage being the most frequent complication (50 cases, 0.68%). Infectious complications developed in 14 cases (0.19%) (Mediastinitis, 7; pneumonia, 4; pericarditis, 1; cyst infection, 1; and sepsis, 1). Pneumothorax developed in 2 cases (0.03%), one of which required tube drainage. Regarding the outcome of the cases with complications, prolonged hospitalization was observed in 14 cases, life-threatening conditions in 4, and death in 1 (severe cerebral infarction) (mortality rate, 0.01%). Breakage of the ultrasound bronchoscope occurred in 98 cases (1.33%) in 67 facilities (31.9%), and that of the puncture needle in 15 cases (0.20%) in 8 facilities (3.8%). CONCLUSIONS: Although the complication rate associated with EBUS-TBNA was found to be low, severe complications, including infectious complications, were observed, and the incidence of device breakage was high. Since the use of EBUS-TBNA is rapidly expanding in Japan, an educational program for its safe performance should be immediately established.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Pneumotórax
/
Complicações Pós-Operatórias
/
Infecção da Ferida Cirúrgica
/
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico
/
Hemorragia
/
Neoplasias Pulmonares
Tipo de estudo:
Clinical_trials
/
Etiology_studies
/
Incidence_studies
/
Prognostic_studies
/
Qualitative_research
/
Risk_factors_studies
Limite:
Adult
/
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
País/Região como assunto:
Asia
Idioma:
En
Revista:
Respir Res
Ano de publicação:
2013
Tipo de documento:
Article
País de afiliação:
Japão