Your browser doesn't support javascript.
loading
Formative assessment based on an audit and feedback improves nuchal translucency ultrasound image quality.
Chalouhi, Gihad E; Salomon, Laurent J; Fontanges, Marianne; Althuser, Marc; Haddad, Georges; Scemama, Olivier; Chabot, Jean-Michel; Duyme, Michel; Fries, Nicolas.
Afiliação
  • Chalouhi GE; Department of Obstetrics and Fetal Medicine, Paris Descartes University, Assistance Publique-Hôpitaux de Paris, Hôpital Necker-Enfants-Malades, Paris, France.
J Ultrasound Med ; 32(9): 1601-5, 2013 Sep.
Article em En | MEDLINE | ID: mdl-23980221
OBJECTIVES: The purpose of this work was to study the impact of an audit and feedback on the quality of routine first-trimester nuchal transparency ultrasound images. METHODS: Eighty-eight sonographers were each sent 2 different series of 30 consecutive nuchal translucency images at a mean interval of 3 months to a dedicated, protected server for remote double-blind independent analysis based on the new Collège Français d'Echographie Foetale/Centre National de la Recherche Scientifique image-scoring method (https://www.cfef.org/evaluation/ISMCFEFCNRS.pdf). The sonographers were classified as low (score below the median) or high (score above the median) scorers for each series. Before their second evaluation, 73 of the 88 sonographers received a feedback report on their first series of images, whereas the other 15 participants received no feedback. The baseline characteristics of the participants who did and did not receive feedback were comparable. RESULTS: Participants who received feedback increased their average score significantly, from a mean ± SD of 11.1 ± 1.3 to 13.4 ± 1.4 among low scorers (P < .00001) and from 15.1 ± 1.2 to 16.0 ± 1.4 among high scorers (P < .001), whereas no significant change was seen among participants who received no feedback (low scorers, 10.9 ± 1.5 to 12.1 ± 2.0; P = .11; high scorers, 14.7 ± 1.3 to 14.6 ± 1.3; P = .99). The proportion of satisfactory images increased by 48% among low scorers who received feedback. CONCLUSIONS: Formative assessment based on a moderately intensive audit and feedback is feasible and effective for improving the quality of routine first-trimester nuchal transparency ultrasound images.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Competência Profissional / Medição da Translucência Nucal / Educação Médica Continuada / Avaliação de Desempenho Profissional / Auditoria Médica Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Ultrasound Med Ano de publicação: 2013 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Competência Profissional / Medição da Translucência Nucal / Educação Médica Continuada / Avaliação de Desempenho Profissional / Auditoria Médica Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Ultrasound Med Ano de publicação: 2013 Tipo de documento: Article País de afiliação: França