ABSTRACT

PURPOSE:

To evaluate technical success and long-term outcomes of percutaneous primary jejunostomy tubes for postpyloric enteral feeding compared with percutaneous gastrojejunostomy (GJ) tubes. MATERIALS AND

METHODS:

Over a 25-month interval, 41 consecutive patients (26 male; mean age, 55.9 y) underwent attempted fluoroscopy-guided direct percutaneous jejunostomy tube insertion. Insertions at previous jejunostomy tube sites were excluded. The comparison group consisted of all primary GJ tube insertions performed over a 12-month interval concomitant with the jejunostomy tube interval (N = 169; 105 male; mean age, 59.4 y). Procedural, radiologic, and clinical data were retrospectively reviewed. Intervention rates were expressed as events per 100 catheter-days.

RESULTS:

The technical success rate for percutaneous jejunostomy tube insertion was 96%, versus 93% for GJ tubes (P = .47). Mean fluoroscopy times were similar for jejunostomy and GJ tubes (9.8 vs 10.0 min, respectively; P value not significant). Jejunostomy tubes exhibited a lower rate of catheter dysfunction than GJ tubes, with catheter exchange rates of 0.24 versus 0.93, respectively, per 100 catheter-days (P = .045). GJ tube tip retraction into the stomach occurred in 9.5% of cases, at a rate of 0.21 per 100 catheter-days. Intervention rates related to leakage were 0.19 and 0.03 for jejunostomy and GJ tubes, respectively (P < .01). Jejunostomy and GJ tubes exhibited similar rates of catheter exchange for occlusion and replacement as a result of inadvertent removal. No major complications were encountered in either group.

CONCLUSIONS:

Percutaneous insertion of primary jejunostomy tubes demonstrated technical success and complication rates similar to those of GJ tubes. Jejunostomy tubes exhibited a lower dysfunction rate but a higher leakage rate compared with GJ tubes.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Jejunostomia / Derivação Gástrica / Radiografia Intervencionista / Nutrição Enteral Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Vasc Interv Radiol Assunto da revista: ANGIOLOGIA / RADIOLOGIA Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Jejunostomia / Derivação Gástrica / Radiografia Intervencionista / Nutrição Enteral Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Vasc Interv Radiol Assunto da revista: ANGIOLOGIA / RADIOLOGIA Ano de publicação: 2013 Tipo de documento: Article