Nonenhanced ECG-gated quiescent-interval single shot MRA: image quality and stenosis assessment at 3 tesla compared with contrast-enhanced MRA and digital subtraction angiography.
Hansmann, Jan; Morelli, John N; Michaely, Henrik J; Riester, Thomas; Budjan, Johannes; Schoenberg, Stefan O; Attenberger, Ulrike I.
Afiliação
  • Hansmann J; Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim - Heidelberg University, Mannheim, Germany.
J Magn Reson Imaging ; 39(6): 1486-93, 2014 Jun.
Article em En | MEDLINE | ID: mdl-24338813
PURPOSE: To evaluate the diagnostic accuracy of a nonenhanced electrocardiograph-gated quiescent-interval single shot MR-angiography (QISS-MRA) at 3 Tesla with contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA) serving as reference standard. MATERIALS AND METHODS: Following institutional review board approval, 16 consecutive patients with peripheral arterial disease underwent a combined peripheral MRA protocol consisting of a large field-of-view QISS-MRA, continuous table movement MRA, and an additional time-resolved MRA of the calves. DSA correlation was available in eight patients. Image quality and degree of stenosis was assessed. Sensitivity and specificity of QISS-MRA was evaluated with CE-MRA and DSA serving as the standards of reference and compared using the Fisher exact test. RESULTS: With the exception of the calf station, image quality with QISS-MRA was rated statistically significantly less than that of CE-MRA (P < 0.05, P = 0.17, and P = 0.6, respectively). A greater percentage of segments were not accessible with QISS-MRA (19.5-20.1%) in comparison to CE-MRA (10.9%). Relative to DSA, sensitivity for QISS-MRA was high (100% versus 91.2% for CE-MRA, P = 0.24) in the evaluated segments; however, specificity (76.5%) was substantially less than that of CE-MRA (94.6%, P = 0.003). CONCLUSION: Overall image quality and specificity of QISS-MRA at 3T are diminished relative to CE-MRA. However, when image quality is adequate, QISS-MRA has high sensitivity and, thus, has potential use in patients with contraindications to gadolinium.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aumento da Imagem / Angiografia Digital / Doenças Vasculares Periféricas / Angiografia por Ressonância Magnética / Meios de Contraste / Eletrocardiografia Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aumento da Imagem / Angiografia Digital / Doenças Vasculares Periféricas / Angiografia por Ressonância Magnética / Meios de Contraste / Eletrocardiografia Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Alemanha