Your browser doesn't support javascript.
loading
Real-time assessment of pulmonary vein disconnection during cryoablation of atrial fibrillation: can it be 'achieved' in almost all cases?
Boveda, Serge; Providência, Rui; Albenque, Jean-Paul; Combes, Nicolas; Combes, Stéphane; Hireche, Hassiba; Casteigt, Benjamin; Bouzeman, Abdeslam; Jourda, François; Narayanan, Kumar; Marijon, Eloi.
Afiliação
  • Boveda S; Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 ToulouseCedex 3, France sboveda@clinique-pasteur.com.
  • Providência R; Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 ToulouseCedex 3, France.
  • Albenque JP; Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 ToulouseCedex 3, France.
  • Combes N; Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 ToulouseCedex 3, France.
  • Combes S; Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 ToulouseCedex 3, France.
  • Hireche H; Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 ToulouseCedex 3, France.
  • Casteigt B; Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 ToulouseCedex 3, France.
  • Bouzeman A; Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 ToulouseCedex 3, France.
  • Jourda F; Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 ToulouseCedex 3, France.
  • Narayanan K; Paris Cardiovascular Research Center, Paris, France.
  • Marijon E; Paris Cardiovascular Research Center, Paris, France.
Europace ; 16(6): 826-33, 2014 Jun.
Article em En | MEDLINE | ID: mdl-24351882
AIM: Real-time assessment of pulmonary vein (PV) disconnection is possible using an inner circular mapping catheter during cryoablation of atrial fibrillation (AF). However, it has been recently demonstrated that such continuous monitoring may only be possible in <50% of PVs. We hypothesized that a stepwise mapping approach, including pacing manoeuvres, could optimize monitoring of real-time PV disconnection during ablation. METHODS AND RESULTS: Single-centre, prospective observational study (NCT01843465) including 34 consecutive eligible patients (128 PVs) undergoing a first procedure of cryoballoon ablation of AF using the Artic Front Advance(®) 28 mm catheter and a 20 mm diameter Achieve(®) catheter (AC) in all cases. Monitoring of real-time entrance block was possible, when AC was maintained in the standard position (distal to the tip of the Artic Front Advance(®) catheter) in 47 (36.7%) PVs. In an additional 63 cases (49.2%), such monitoring was possible after moving AC to a more proximal position and using different torqueing movements. Finally, using supplemental systematic pacing manoeuvres to test exit block, real-time assessment of PV disconnection was possible in 15 (11.7%) more PVs. Overall, real-time assessment of PV disconnection was possible in 97.7% of cases, after a mean duration of 48.6 ± 33.0 s. CONCLUSION: Our results suggest that optimal use of the AC, with a systematic stepwise mapping approach, may dramatically improve the real-time monitoring of PV disconnection during AF cryoablation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Mapeamento Potencial de Superfície Corporal / Criocirurgia / Cirurgia Assistida por Computador / Sistema de Condução Cardíaco Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Mapeamento Potencial de Superfície Corporal / Criocirurgia / Cirurgia Assistida por Computador / Sistema de Condução Cardíaco Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: França