Your browser doesn't support javascript.
loading
Permanent pacemaker implantation after transcatheter aortic valve implantation: impact on late clinical outcomes and left ventricular function.
Urena, Marina; Webb, John G; Tamburino, Corrado; Muñoz-García, Antonio J; Cheema, Asim; Dager, Antonio E; Serra, Vicenç; Amat-Santos, Ignacio J; Barbanti, Marco; Immè, Sebastiano; Briales, Juan H Alonso; Benitez, Luis Miguel; Al Lawati, Hatim; Cucalon, Angela Maria; García Del Blanco, Bruno; López, Javier; Dumont, Eric; Delarochellière, Robert; Ribeiro, Henrique B; Nombela-Franco, Luis; Philippon, François; Rodés-Cabau, Josep.
Afiliação
  • Urena M; Quebec Heart & Lung Institute, Laval University, Quebec City, QC, Canada (M.U., E.D., R.D., H.B.R., L.N.-F., F.P., J.R.-C.); St. Paul's Hospital, University of British Columbia, Vancouver, BC, Canada (J.G.W., M.B.); Ferrarotto Hospital, University of Catania, Catania, Italy (C.T., M.B., S.I.); Hospital Clínico de Málaga, Universidad de Málaga, Málaga, Spain (A.J.M.-G., J.H.A.B.); St. Michael's Hospital, Toronto University, Toronto, ON, Canada (A.C., H.A.L.); Clínica de Occidente de Cali, Cal
Circulation ; 129(11): 1233-43, 2014 Mar 18.
Article em En | MEDLINE | ID: mdl-24370552
ABSTRACT

BACKGROUND:

Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND

RESULTS:

A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121).

CONCLUSIONS:

The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Marca-Passo Artificial / Cateterismo Cardíaco / Função Ventricular Esquerda / Implante de Prótese de Valva Cardíaca Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Circulation Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Marca-Passo Artificial / Cateterismo Cardíaco / Função Ventricular Esquerda / Implante de Prótese de Valva Cardíaca Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Circulation Ano de publicação: 2014 Tipo de documento: Article