Your browser doesn't support javascript.
loading
A 1-Year Prospective Clinical and Radiographic Study of Early-Loaded Bone Level Implants in the Posterior Maxilla.
Markovic, Aleksa; Colic, Snjezana; Scepanovic, Miodrag; Misic, Tijana; Ðinic, Ana; Bhusal, Dinesh Sharma.
Afiliação
  • Markovic A; Department of Oral Surgery, School of Dentistry, University of Belgrade, Belgrade, Serbia.
  • Colic S; Department of Oral Surgery, School of Dentistry, University of Belgrade, Belgrade, Serbia.
  • Scepanovic M; Department of Prosthodontics, School of Dentistry, University of Belgrade, Belgrade, Serbia.
  • Misic T; Department of Oral Surgery, School of Dentistry, University of Belgrade, Belgrade, Serbia.
  • Ðinic A; Department of Oral Surgery, School of Dentistry, University of Belgrade, Belgrade, Serbia.
  • Bhusal DS; Department of Oral Surgery, School of Dentistry, University of Belgrade, Belgrade, Serbia.
Clin Implant Dent Relat Res ; 17(5): 1004-13, 2015 Oct.
Article em En | MEDLINE | ID: mdl-24461229
PURPOSES: The primary aim of the study was to investigate a 1-year success rate of early-loaded bone level implants with a chemically modified sand-blasted, large grit, acid-etched surface (SLActive®, Institut Straumann AG, Basel, Switzerland) in the posterior maxilla. Secondary objectives included stability of these implants and peri-implant bone level. MATERIALS AND METHODS: Bone level® implants (Institut Straumann AG) inserted into premolar and/or molar maxillary sites were loaded after 6 weeks of healing. The implants were monitored for 1 year using the following outcome measures: implant success, primary and secondary stability, and peri-implant bone level. RESULTS: Out of 37 implants placed in 13 patients, 36 reached sufficient stability and were early loaded, whereas one underwent a delayed loading protocol. One-year success rate of early-loaded implants was 100%. Implant stability at baseline was 71.7 ± 5. 6 to be steadily increased thereafter up to 1 year (80.3 ± 3.3), except at 2 weeks when a nonsignificant decrease was noticed (71.9 ± 3.9). Continuous and significant bone loss was observed, reaching 0.4 ± 0.1 mm in the first postoperative year. CONCLUSION: Bone level implants with the SLActive surface placed into low-density bone and loaded after 6 weeks of healing can predictably achieve and maintain a successful tissue integration.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implantes Dentários / Osseointegração / Implantação Dentária Endóssea / Maxila Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Implant Dent Relat Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implantes Dentários / Osseointegração / Implantação Dentária Endóssea / Maxila Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Implant Dent Relat Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2015 Tipo de documento: Article