Your browser doesn't support javascript.
loading
Reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.
Peixinho, Carolina Carneiro; Martins, Natália Santos da Fonseca; de Oliveira, Liliam Fernandes; Machado, João Carlos.
Afiliação
  • Peixinho CC; Biomedical Engineering Program, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil ; Laboratory of Biomechanics, Department of Biosciences and Physical Activity, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
  • Martins NS; Biomedical Engineering Program, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil ; Laboratory of Biomechanics, Department of Biosciences and Physical Activity, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
  • de Oliveira LF; Biomedical Engineering Program, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil ; Laboratory of Biomechanics, Department of Biosciences and Physical Activity, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
  • Machado JC; Biomedical Engineering Program, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil ; Post-Graduation Program in Surgical Sciences, Department of Surgery, School of Medicine, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
PLoS One ; 9(2): e87691, 2014.
Article em En | MEDLINE | ID: mdl-24505306
ABSTRACT
This study used ultrasound biomicroscopy (UBM) to quantify the pennation angle (PA) and muscle thickness (MT) of rat skeletal muscle and evaluated the reliability and reproducibility of the method by statistical analysis, determining the coefficient of variation (CV), intraclass correlation coefficient (ICC) and typical error of measurement. A UBM system with a center frequency of 40 MHz was used to acquire images of the right lateral gastrocnemius of ten male Wistar rats on two different days and with two ankle positions (90° or 150°). Two independent measurements of the PA and MT were randomly performed in each of three picture frames. The analysis resulted in CVs of 10.47% and 4.81% for the PA and the MT, respectively, for the ankle at 90° and 9.24% and 5.98% for the ankle at 150°. Additionally, the ICC values ranged from 0.75 to 0.92 for the PA and 0.57 to 0.99 for the MT. Statistically significant differences between the ankle positions were observed for the PA (p = 0.00013). The reliability of the PA and MT measurements for the rat right lateral gastrocnemius, determined from the ultrasound biomicroscopy images, was high (>0.90) for the methodology proposed. This finding indicates the potential of ultrasound biomicroscopy for quantitative muscle characterization and the longitudinal examination of tissue adaptation to different conditions of use, disease and rehabilitation.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Músculo Esquelético / Microscopia Acústica Limite: Animals Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Músculo Esquelético / Microscopia Acústica Limite: Animals Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil