Development of a method for the determination of total bisphenol a at trace levels in human blood and urine and elucidation of factors influencing method accuracy and sensitivity.
Markham, Dan; Waechter, John; Budinsky, Robert; Gries, Wolfgang; Beyer, Dieter; Snyder, Stephanie; Dimond, Stephen; Rajesh, V N; Rao, Narayana; Connolly, Paul; Neeley, Mark; Hentges, Steven.
Afiliação
  • Markham D; 1Toxicology and Environmental Research & Consulting, The Dow Chemical Company, Midland, MI, USA.
J Anal Toxicol ; 38(4): 194-203, 2014 May.
Article em En | MEDLINE | ID: mdl-24567285
This publication describes a method for the determination of total bisphenol A (BPA and conjugated BPA) following enzyme hydrolysis and is intended as a companion to our previously developed analytical method for the determination of free BPA (the aglycone) in human blood and urine using high-performance liquid chromatography-tandem mass spectrometry ( 1). That free BPA method provided a means to account for and/or eliminate background contamination and demonstrated accuracy and reproducibility in both matrices fortified with BPA or a surrogate analyte ((13)C BPA) at a low method quantitation limit (MQL) of 0.1-0.2 ng/mL. In contrast to the free BPA method results and based on stringent accuracy, precision and confirmation criteria set for the MQLs of the method developed for total BPA, the MQL achieved in blood was 1.020-2.550 and 0.510-1.020 ng/mL in urine. These data showed higher MQLs than the desired MQLs of 0.5 ng/mL (blood) and 0.2 ng/mL (urine) with increased variability between analyses which demonstrates the importance of generating method validation data with each analysis. In contrast, the MQL achieved for (13)C BPA-G (monoglucuronide as a surrogate analyte in blood was 0.2-0.5 and 0.2 ng/mL in urine illustrating that the method is capable of meeting lower MQL requirements if the contribution from exogenous BPA can be well controlled. This method for the determination total BPA in human blood and urine is intended to be used in conjunction with the free BPA method ( 1) to obtain accurate and complete BPA biomonitoring data to support human exposure assessments.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenóis / Compostos Benzidrílicos / Monitoramento Ambiental / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Poluentes Ambientais / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Anal Toxicol Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenóis / Compostos Benzidrílicos / Monitoramento Ambiental / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Poluentes Ambientais / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Anal Toxicol Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos