Your browser doesn't support javascript.
loading
The role of sodium alginate in improving floc size and strength and the subsequent effects on ultrafiltration membrane fouling.
Wang, Yan; Li, Xiangzuo; Wu, Caihong; Zhao, Yanxia; Gao, Bao-Yu; Yue, Qinyan.
Afiliação
  • Wang Y; Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Jinan 250100, People's Republic of China. wangyan_sdjn@yahoo.com.cn
  • Li X; Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Jinan 250100, People's Republic of China.
  • Wu C; Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Jinan 250100, People's Republic of China.
  • Zhao Y; Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Jinan 250100, People's Republic of China.
  • Gao BY; Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Jinan 250100, People's Republic of China.
  • Yue Q; Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Jinan 250100, People's Republic of China.
Environ Technol ; 35(1-4): 10-7, 2014.
Article em En | MEDLINE | ID: mdl-24600835
ABSTRACT

BACKGROUND:

Dosing environment-friendly polymer as coagulant aids is an encouraging method in water treatment to obtain desirable floc characteristics. Sodium alginate (SA) was used as the coagulant aid for synthetic humic acid (HA) water treatment to investigate the effect on flocs characteristics and ultrafiltration (UF) membrane fouling.

RESULTS:

When SA content was 0.3 mg L-1, the treatment of HA by polyaluminium chloride (PAC) plus SA (PAC/SA) yielded the maximum removal efficiency of 66.5%, which was higher than the maximum HA removal efficiency of PAC (58%). Moreover, the HA flocs size of PAC would grow from 269 to 367 Iim after SA was added. Strength factor and recovery factor of PAC/SA were larger than those of PAC. These resulted in the improvement in subsequent UF membrane performance. The membrane fouling decreased in the following order the raw water > PAC coagulated water > PAC/SA coagulated water.

CONCLUSION:

The study showed that the application of SA as coagulant aids resulted in larger and stronger flocs, which would improve treatment efficiency of the coagulation process. And the flocs formed by PAC/SA contributed to the restriction of the fouling of UF membrane, which would decrease the cost of advanced water treatment.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Ultrafiltração / Contaminação de Equipamentos / Purificação da Água / Alginatos / Membranas Artificiais Idioma: En Revista: Environ Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2014 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Ultrafiltração / Contaminação de Equipamentos / Purificação da Água / Alginatos / Membranas Artificiais Idioma: En Revista: Environ Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2014 Tipo de documento: Article