Your browser doesn't support javascript.
loading
Optical quality and visual performance with customised soft contact lenses for keratoconus.
Jinabhai, Amit; O'Donnell, Clare; Tromans, Cindy; Radhakrishnan, Hema.
Afiliação
  • Jinabhai A; Faculty of Life Sciences, The University of Manchester, Manchester, UK.
Ophthalmic Physiol Opt ; 34(5): 528-39, 2014 Sep.
Article em En | MEDLINE | ID: mdl-24758229
ABSTRACT

PURPOSE:

This study investigated how aberration-controlling, customised soft contact lenses corrected higher-order ocular aberrations and visual performance in keratoconic patients compared to other forms of refractive correction (spectacles and rigid gas-permeable lenses).

METHODS:

Twenty-two patients (16 rigid gas-permeable contact lens wearers and six spectacle wearers) were fitted with standard toric soft lenses and customised lenses (designed to correct 3rd-order coma aberrations). In the rigid gas-permeable lens-wearing patients, ocular aberrations were measured without lenses, with the patient's habitual lenses and with the study lenses (Hartmann-Shack aberrometry). In the spectacle-wearing patients, ocular aberrations were measured both with and without the study lenses. LogMAR visual acuity (high-contrast and low-contrast) was evaluated with the patient wearing their habitual correction (of either spectacles or rigid gas-permeable contact lenses) and with the study lenses.

RESULTS:

In the contact lens wearers, the habitual rigid gas-permeable lenses and customised lenses provided significant reductions in 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS and higher-order RMS error (p ≤ 0.004). In the spectacle wearers, the standard toric lenses and customised lenses significantly reduced 3rd-order RMS and higher-order RMS errors (p ≤ 0.005). The spectacle wearers showed no significant differences in visual performance measured between their habitual spectacles and the study lenses. However, in the contact lens wearers, the habitual rigid gas-permeable lenses and standard toric lenses provided significantly better high-contrast acuities compared to the customised lenses (p ≤ 0.006).

CONCLUSIONS:

The customised lenses provided substantial reductions in ocular aberrations in these keratoconic patients; however, the poor visual performances achieved with these lenses are most likely to be due to small, on-eye lens decentrations.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lentes de Contato Hidrofílicas / Ceratocone Tipo de estudo: Etiology_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Ophthalmic Physiol Opt Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lentes de Contato Hidrofílicas / Ceratocone Tipo de estudo: Etiology_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Ophthalmic Physiol Opt Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Reino Unido