Your browser doesn't support javascript.
loading
Development and validation of a sensitive UHPLC-MS/MS method for the simultaneous analysis of tramadol, dextromethorphan chlorpheniramine and their major metabolites in human plasma in forensic context: application to pharmacokinetics.
Heneedak, Hala M; Salama, Ismail; Mostafa, Samia; El-Kady, Ehab; El-Sadek, Mohamed.
Afiliação
  • Heneedak HM; Analytical Toxicology Laboratory, Forensic Medicine Authority, Ismailia, Egypt.
  • Salama I; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt.
  • Mostafa S; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt.
  • El-Kady E; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Cairo University, Cairo, Egypt.
  • El-Sadek M; Department of Medicinal Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt.
Biomed Chromatogr ; 29(7): 998-1007, 2015 Jul.
Article em En | MEDLINE | ID: mdl-25417559
The prerequisites for forensic confirmatory analysis by LC/MS/MS with respect to European Union guidelines are chromatographic separation, a minimum number of two MS/MS transitions to obtain the required identification points and predefined thresholds for the variability of the relative intensities of the MS/MS transitions (MRM transitions) in samples and reference standards. In the present study, a fast, sensitive and robust method to quantify tramadol, chlorpheniramine, dextromethorphan and their major metabolites, O-desmethyltramadol, dsmethyl-chlorpheniramine and dextrophan, respectively, in human plasma using ibuprofen as internal standard (IS) is described. The analytes and the IS were extracted from plasma by a liquid-liquid extraction method using ethyl acetate-diethyl-ether (1:1). Extracted samples were analyzed by ultra-high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Chromatographic separation was performed by pumping the mobile phase containing acetonitrile, water and formic acid (89.2:11.7:0.1) for 2.0 min at a flow rate of 0.25 µL/min into a Hypersil-Gold C18 column, 20 × 2.0 mm (1.9 µm) from Thermoscientific, New York, USA. The calibration curve was linear for the six analytes. The intraday precision (RSD) and accuracy (RE) of the method were 3-9.8 and -1.7-4.5%, respectively. The analytical procedure herein described was used to assess the pharmacokinetics of the analytes in 24 healthy volunteers after a single oral dose containing 50 mg of tramadol hydrochloride, 3 mg chlorpheniramine maleate and 15 mg of dextromethorphan hydrobromide.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tramadol / Clorfeniramina / Cromatografia Líquida de Alta Pressão / Dextrometorfano / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Egito

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tramadol / Clorfeniramina / Cromatografia Líquida de Alta Pressão / Dextrometorfano / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Egito