Circuit life versus bleeding risk: the impact of achieved activated partial thromboplastin time versus achieved filtration fraction.
MacEwen, Clare; Watkinson, Peter; Winearls, Christopher.
Afiliação
  • MacEwen C; Adult Intensive Care Unit, Oxford University Hospitals NHS Trust, Oxford, UK.
  • Watkinson P; Oxford Kidney Unit, Oxford University Hospitals NHS Trust, Oxford, UK.
  • Winearls C; Institute of Biomedical Engineering, Oxford University, Oxford, UK.
Ther Apher Dial ; 19(3): 259-66, 2015 Jun.
Article em En | MEDLINE | ID: mdl-25511624
ABSTRACT
Whilst prolonging hemofilter (circuit) life, heparin increases bleeding risk. The impact of achieved activated partial thromboplastin time (APTT) on circuit life and bleeding risk has not been assessed in a modern critically ill cohort. Lowering filtration fraction may be an alternative means of prolonging circuit life, but is often overlooked in critical care. An observational study of 309 consecutive circuits in a general intensive care unit was conducted using a wide target APTT range. Multilevel modeling was used to predict circuit life and bleeding according to achieved APTT and filtration fraction. Independent predictors of circuit failure (i.e. unplanned ending of treatment) included filtration fraction (P<0.001, HR 1.07 per 1% increase), peak APTT (P<0.001, HR 0.8 per 10 s increase or 0.3 APTR increase) and baseline PT (P=0.014, HR 0.91 for every 50% increase). The only significant predictor of bleeding was peak APTT (P=0.017, OR 1.05 per 10 s increase). Every 10 s APTT increase was associated with a 20% reduction in circuit failure, but a 5% increase in hemorrhage. A 3% reduction in filtration fraction was associated with the same improvement in circuit life as a 10 s increase in APTT. Increasing APTT prolongs circuit life but carries a substantial risk of bleeding even in modern practice. Filtration fraction has a large impact on circuit life in the critically ill a 3% reduction in filtration fraction, e.g. by increasing blood flow or delivering some of the clearance via dialysis, would be expected to reduce circuit failure as much as a 10 s increase in APTT.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Heparina / Terapia de Substituição Renal / Hemorragia / Anticoagulantes Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ther Apher Dial Assunto da revista: HEMATOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Heparina / Terapia de Substituição Renal / Hemorragia / Anticoagulantes Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ther Apher Dial Assunto da revista: HEMATOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Reino Unido