Your browser doesn't support javascript.
loading
A feasibility study of Fricke dosimetry as an absorbed dose to water standard for 192Ir HDR sources.
deAlmeida, Carlos Eduardo; Ochoa, Ricardo; Lima, Marilene Coelho de; David, Mariano Gazineu; Pires, Evandro Jesus; Peixoto, José Guilherme; Salata, Camila; Bernal, Mario Antônio.
Afiliação
  • deAlmeida CE; Laboratório de Ciências Radiológicas, LCR-IBRAG-UERJ, Rio de Janeiro, RJ, Brazil.
  • Ochoa R; Laboratório de Ciências Radiológicas, LCR-IBRAG-UERJ, Rio de Janeiro, RJ, Brazil.
  • Lima MC; Laboratório de Ciências Radiológicas, LCR-IBRAG-UERJ, Rio de Janeiro, RJ, Brazil.
  • David MG; Laboratório de Ciências Radiológicas, LCR-IBRAG-UERJ, Rio de Janeiro, RJ, Brazil.
  • Pires EJ; Laboratório de Ciências Radiológicas, LCR-IBRAG-UERJ, Rio de Janeiro, RJ, Brazil.
  • Peixoto JG; Laboratório Nacional de Metrologia das Radiações Ionizantes, LNMRI-IRD, Rio de Janeiro, RJ, Brazil.
  • Salata C; Laboratório de Ciências Radiológicas, LCR-IBRAG-UERJ, Rio de Janeiro, RJ, Brazil.
  • Bernal MA; Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, Campinas, SP, Brazil.
PLoS One ; 9(12): e115155, 2014.
Article em En | MEDLINE | ID: mdl-25521914
High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brachytherapy sources is presented in this study. The main goal of this paper is to demonstrate the potential usefulness of the Fricke dosimetry technique for the standardization of the quantity absorbed dose to water for 192Ir sources. A molded, double-walled, spherical vessel for water containing the Fricke solution was constructed based on the Fricke system. The authors measured the absorbed dose to water and compared it with the doses calculated using the AAPM TG-43 report. The overall combined uncertainty associated with the measurements using Fricke dosimetry was 1.4% for k = 1, which is better than the uncertainties reported in previous studies. These results are promising; hence, the use of Fricke dosimetry to measure the absorbed dose to water as a standard for HDR 192Ir may be possible in the future.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Soluções / Braquiterapia / Radioisótopos de Irídio / Compostos Ferrosos Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Soluções / Braquiterapia / Radioisótopos de Irídio / Compostos Ferrosos Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil