Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: determination of allowable interference limits according to different calculation methods.
Monneret, Denis; Mestari, Fouzi; Atlan, Gregory; Corlouer, Camille; Ramani, Zo; Jaffre, Jeremy; Dever, Sylvie; Fressart, Veronique; Alkouri, Rana; Lamari, Foudil; Devilliers, Catherine; Imbert-Bismut, Françoise; Bonnefont-Rousselot, Dominique.
Afiliação
  • Monneret D; Department of Metabolic Biochemistry, La Pitié Salpêtrière-Charles Foix University Hospital (AP-HP) , Paris.
Scand J Clin Lab Invest ; 75(2): 162-9, 2015 Apr.
Article em En | MEDLINE | ID: mdl-25608598
OBJECTIVES: To determine the hemolysis interference on biochemical tests and immunoassays performed on Roche Diagnostics analyzers, according to different maximum allowable limits. DESIGN AND METHODS: Heparinized plasma and serum pools, free of interferences, were overloaded by increasing amounts of a hemoglobin-titrated hemolysate. This interference was evaluated for 45 analytes using Modular(®) and Cobas(®) analyzers. For each parameter, the hemolysis index (HI) corresponding to the traditional ± 10% change of concentrations from baseline (± 10%Δ) was determined, as well as those corresponding to the analytical change limit (ACL), and to the reference change value (RCV). Then, the relative frequencies distribution (% RFD) of hemolyzed tests performed in a hospital laboratory over a 25-day period were established for each HI as allowable limit. RESULTS: Considering the ± 10%Δ, the analyte concentrations enhanced by hemolysis were: Lactate dehydrogenase (LDH), aspartate aminotransferase (AST), folate, potassium, creatine kinase, phosphorus, iron, alanine aminotransferase, lipase, magnesium and triglycerides, decreasingly. The analyte concentrations decreased by hemolysis were: Haptoglobin, high-sensitive troponin T and alkaline phosphatase. Over the 25-day period, the % RFD of tests impacted more than 10%Δ by hemolysis were < 7% for LDH; < 5% for AST, folates and iron; and < 1% for the other analytes. Considering the ACL, HI were lower, giving % RFD substantially increased for many analytes, whereas only four analytes remain sensitive to hemolysis when considering RCV. CONCLUSION: This study proposes new HI based on different allowable limits, and can therefore serve as a starting point for future harmonization of hemolysis interference evaluation needed in routine laboratory practice.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Imunoensaio / Hemólise Limite: Humans Idioma: En Revista: Scand J Clin Lab Invest Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Imunoensaio / Hemólise Limite: Humans Idioma: En Revista: Scand J Clin Lab Invest Ano de publicação: 2015 Tipo de documento: Article