Your browser doesn't support javascript.
loading
Surveillance for lower airway pathogens in mechanically ventilated patients by metabolomic analysis of exhaled breath: a case-control study.
Fowler, Stephen J; Basanta-Sanchez, Maria; Xu, Yun; Goodacre, Royston; Dark, Paul M.
Afiliação
  • Fowler SJ; Manchester Academic Health Science Centre, and NIHR Respiratory and Allergy Clinical Research Facility, University of Manchester, University Hospital of South Manchester, Manchester, UK Lancashire Teaching Hospitals NHS Foundation Trust, Preston, UK.
  • Basanta-Sanchez M; Manchester Academic Health Science Centre, and NIHR Respiratory and Allergy Clinical Research Facility, University of Manchester, University Hospital of South Manchester, Manchester, UK.
  • Xu Y; School of Chemistry & Manchester Institute of Biotechnology, University of Manchester, Manchester, UK.
  • Goodacre R; School of Chemistry & Manchester Institute of Biotechnology, University of Manchester, Manchester, UK.
  • Dark PM; Manchester Academic Health Science Centre, and NIHR Respiratory and Allergy Clinical Research Facility, University of Manchester, University Hospital of South Manchester, Manchester, UK Salford Royal Hospitals NHS Foundation Trust, Salford, UK.
Thorax ; 70(4): 320-5, 2015 Apr.
Article em En | MEDLINE | ID: mdl-25661115
BACKGROUND: Healthcare associated infections, including ventilator associated pneumonia, are difficult to diagnose and treat, and are associated with significant morbidity, mortality and cost. We aimed to demonstrate proof of concept that breath volatile profiles were associated with the presence of clinically relevant pathogens in the lower respiratory tract. METHODS: Patients with sterile brain injury requiring intubation and ventilation on the intensive care unit were eligible for inclusion. Serial clinical and breath data were obtained three times a week, from admission up to a maximum of 10 days. Bronchial lavage for semiquantitative culture was collected immediately prior to breath sampling. Breath samples were collected in triplicate for off-line analysis by thermal-desorption/gas chromatography/time-of-flight mass spectrometry. Breath data were recorded as retention time/mass ion pairs, and analysed (pathogen present vs absent) by ANOVA-mean centre principal component analysis. RESULTS: Samples were collected from 46 patients (mean (SD) age 49 (19) years; 27 male). The dominant factors affecting breath sample analysis were the individual breath profile and duration of intubation. When these were taken into account, clear separation was seen between breath profiles at each time point by the presence/absence of pathogens. Loadings plots identified consistent metabolite peaks contributing to this separation at each time point. CONCLUSIONS: Breath volatile analysis is able to classify breath profiles of patients with and without significant pathogen load in the lower respiratory tract. If validated in independent cohorts, these findings could lead to development of rapid non-invasive point-of-care surveillance systems and diagnostics for lower respiratory tract infection in the intensive care unit.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pneumonia Associada à Ventilação Mecânica / Metabolômica Tipo de estudo: Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Thorax Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pneumonia Associada à Ventilação Mecânica / Metabolômica Tipo de estudo: Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Thorax Ano de publicação: 2015 Tipo de documento: Article