Proton partial breast irradiation in the supine position: Treatment description and reproducibility of a multibeam technique.
Pract Radiat Oncol
; 5(4): e283-90, 2015.
Article
em En
| MEDLINE
| ID: mdl-25804105
PURPOSE: Proton-accelerated partial breast irradiation (APBI) is early in its developmental phase without standardized treatment parameters. We report an approach to multibeam proton APBI using a universally available supine setup and deliberate beam arrangement strategy to limit the total area of skin receiving a full dose while being robust for interfraction variation. METHODS AND MATERIALS: Thirty-three American Society for Radiation Oncology consensus-suitable/cautionary APBI candidates were treated using a passively scattered proton beam between 2010 and 2014 to 34 Gy relative biological effectiveness in 10 fractions twice daily. All patients were immobilized in a Vac-Lok cradle, typically with the arm down, and adducted to mound the breast and facilitate multiple, optimal en face beams. Radiopaque wires were placed on the surgical scar and 3 markers separate from the scar were placed elsewhere on the breast. All markers were used for each setup and removed before treatment. Marker displacement, wire rotation, and wire displacement were recorded from 10 random patients (100 orthogonal films). A 15-mm expansion was made to the tumor bed to obtain a clinical target volume, and followed by a 5-mm skin contraction and exclusion of the chest wall. A radial planning target volume margin of 5 mm was used. RESULTS: Across 100 pretreatment images, median displacement of 3 distinct skin set-up markers was 3, 4, and 3 mm. Displacement of the scar wire in the X and Y direction was 0 and 1 mm, respectively. Among 28 verification scans performed, only 1 resulted in adaptive planning because of the initial presence of an air pocket in the lumpectomy cavity that resolved spontaneously during treatment. CONCLUSIONS: APBI proton treatment using a supine approach was largely reproducible. Inter-fraction variation demonstrates 5-mm radial planning margins were adequate; however, outliers do occur and films should be reviewed critically and in real time. This technique is straightforward and could be used at any proton facility without the need for specialized equipment.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Dosagem Radioterapêutica
/
Planejamento da Radioterapia Assistida por Computador
/
Neoplasias da Mama
/
Posicionamento do Paciente
Limite:
Female
/
Humans
Idioma:
En
Revista:
Pract Radiat Oncol
Ano de publicação:
2015
Tipo de documento:
Article